Timeguard SupplyMASTER FST11A Installation & Operating Instructions Manual Download Page 3

2. Battery

The unit has an in-built non replaceable, rechargeable battery, which will keep the 
programmed times during power down situations for up to 4 weeks. If the main 
switch is left in the OFF position for longer than this, the display will go blank. If the 
screen goes blank, once power is restored and 4 hours elapsed (to give a working 
battery charge) reset must be pressed, and times / programmes re-entered.

Supply live 
terminal

Switched 

neutral terminal 

(load neutral 

connection)

Supply neutral 

terminal

Switched live terminal 

(load live connection)

3. Applications

Energy consuming appliances such as immersion heaters and storage heaters up to 
13A total loading can be supplied by the FST11A / FST17A enabling users to make 
use of economy 7.

If the user has other appliances which do not have a push button start such as 
washing machines, dishwashers and tumble dryers these may also be controlled in 
the same way. It can also be used to control lighting, if a neutral is made available. 
Lighting up to 2.5kw filament, or 500W fluorescent can also be controlled.

230 V~
13A

T40

L OUT

N IN

L IN

N OUT

Fig. 2 
FST17A / FST11A Rear Connections

Summary of Contents for SupplyMASTER FST11A

Page 1: ...I N S T A L L A T I O N O P E R A T I N G I N S T R U C T I O N S FUSED SPUR TIMESWITCH Cat No FST11A 24 Hour Cat No FST17A 7 Day Installation Operating Instructions Cat No FST17...

Page 2: ...7A 7 day are units which mount onto a BS 4662 flush mount single box or a BS 5733 surface mount single box 25mm deep in either case There is provision for a single front exit output cable with in buil...

Page 3: ...ral connection Supply neutral terminal Switched live terminal load live connection 3 Applications Energy consuming appliances such as immersion heaters and storage heaters up to 13A total loading can...

Page 4: ...uate for the load to be carried Connect incoming and outgoing cables to the relevant terminals Secure the unit to the back box with the 3 5mm screws provided forming the cables during installation to...

Page 5: ...mmediately In either case the display will initially show the full character set then display The only button which is now active is the time button Now proceed to setting the date time and then progr...

Page 6: ...e minutes Day Prog Adv Time Bst SET Time Prog Adv Time Bst SET Time Prog Adv Time Bst SET Press the Time button briefly to exit date time entry and return to the operating mode The display will now re...

Page 7: ...ng the ON OFF Times FST17A only 8 1 Generating New Programmes The FST17A has four independent ON OFF periods available for programming each day The FST17A is a 7 day programmer with options of 7 days...

Page 8: ...scroll through program 2 ON program 2 OFF program 3 ON program 3 OFF program 4 ON program 4 OFF adding in times as required If you wish to omit programmes just leave dashes in that ON OFF location Pre...

Page 9: ...s Prog briefly There is no automatic exit to the operating mode The reset button can also be used whenever major changes of programmes are required 9 Programming the ON OFF Times FST11A only The FST11...

Page 10: ...mmed ON period In operating mode pressing the Bst boost button once will give an output for one hour The display will show If pushed twice then there will be a 2 hour output The display will show If p...

Page 11: ...r factor correction capacitors 4uF per 65W tube 1hp motor For other loads refer to technical service on 020 8450 0515 In applications such as use of economy seven electricity the full load will not us...

Page 12: ...assistance with the product please contact 67 058 336 Iss 1 5 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 5 years of the date o...

Reviews: