11. Specifications
This product complies with:
LVD Directive 72/23/EEC.
EMC Directive 89/336/EEC.
and relevant clauses of the
following standards:
BS EN 60730-7-2:1992; Particular
requirements. Timers and time switches.
BS1363-4:1995; Specification for 13A
fused connection units.
EN61000-6-3:2001; Emission
Requirements for the RCLI Environment.
EN61000-6-1:2001; Immunity
Requirements for the RCLI Environment.
Permissable loads:
13A resistive.
6A at 0.4 power factor inductive.
10A filament lamps.
500W fluorescent lighting including low
energy lamps with or without power
factor correction capacitors
(4uF per 65W tube).
1hp
motor.
For other loads refer to technical service
on
020-8450-0515
In applications such as use of economy seven electricity the full load will
not usually be switched. In the cases of a washing machine and a dish
washer the load switched on will be water valves only and the load turned
off will be negligible providing an appropriate time interval has been left
to enable the machine to complete it’s program.
Fuse protection BS 1362 as dictated by load.
700 hours (4 weeks) battery back up in case of supply failure, double pole
switch turned off, or 13A fuse blow.
Operating ambient temperature: -10 to +40ºC.
Operating voltage:
230VAC.
4 ON / OFF programmes per day (independent for each day except when
in day groups).