background image

4

5.2  An isolating switch should be installed to 

enable the power to be switched ON and OFF 
for maintenance purposes and to activate the 
manual/auto override function. 

5.3  Disconnect the back box from the luminaire  

by releasing the lugs (left or right side).  
See Image 2.

5.4  Firmly grip the back box with your hand,  

from top and bottom and carefully pull  
away from the luminaire. See Image 3.

5.5  Mark the position of the mounting holes  

on the wall using the back box as a template 
(See image 4). Drill the holes ensuring not to 
infringe with any gas/water pipes or electrical 
cables that may be hidden below the surface. 
Insert the rawl plugs into the holes. Pass the 
230V 50Hz supply and load cables through 
the cable entry points on the back box, 
ensuring the grommets are used to maintain 
the IP rating of the luminaire.

2

3

4

5

5.6  Fix the back box to the wall using the 2 mounting screws, making sure  

it is the correct way up. Take care not to over-tighten the screws to prevent 
damage to the back box. If using a power screwdriver, use the lowest  
torque setting. See image 5.

Summary of Contents for LED200PIRBE

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2x 10W LED Slimline PIR Floodlight Twin Flood Model LED200PIRBE Black Model LED200PIRWHE White ...

Page 2: ...ed does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be earthed 2x 10W LED Non replaceable lamp Energy Usage 20KwH 1000H Lumen Output 2x 840lm Motion Detection Range Up to 10m at 2 5m mounting height Detection Angle 180 Lamp Adjustment Pan and Tilt Wall Mount Pan Outward 21 limited by w...

Page 3: ...N time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 167mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max 300W Fluorescent Lamp Max 200W Parallel Switching A maximum of 4 LED200PIR twin floodlights can be wired in parallel to enable any detector to turn ON all the lights connected Note if you have the...

Page 4: ...o movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of heat in the detection area of its PIR sensor extractor fans tumble dryer exhausts etc including opposite any other light sources such as other security floodlights Reflective surfaces i e pools of wate...

Page 5: ...on the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plugs into the holes Pass the 230V 50Hz supply and load cables through the cable entry points on the back box ensuring the grommets are used to maintain the IP rating of the luminaire 2 3 4 5 5 6 Fix the...

Page 6: ... image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 lugs firmly latch on the left and right hand side indicated by a click See image 7 ...

Page 7: ...terminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the terminal block on the back box as follows Live Supply Brown or Red to L1 Neutral Supply Blue or Black to N Earth Green Yellow to ...

Page 8: ... PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settings however a thin flat head screwdriver or a 2 5mm Allen key could also be used Turn the power to the unit ON See image 8 The lamp will immediately ill...

Page 9: ...lowing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settings however a thin flat head screwdriver or a 2 5mm Allen key could also be used This can be set between 2 seconds to a maximum of 30 minutes Set the control to the desired setting between these limit...

Page 10: ...2 seconds The floodlight will now illuminate continuously for 6 hours or until it is switched back into Auto Mode If the unit starts to operate too late i e when it is very dark Adjust the control slightly clockwise Continue to adjust until the unit operates as desired 8 Lamp Adjustment Pan Tilt adjustment including details when using the optional spacer and corner brackets sold separately or Thin...

Page 11: ... responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching the internal wall switch again twice OFF ON OFF ON within 2 seconds To return to Auto Mode switch the internal wall switch once OFF ON within 2 seconds The floodlight will return to Auto Mode and wil...

Page 12: ... csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com ...