background image

L
N
E

ISOLATION

SWITCH

L

L

N

1

230V AC 50Hz

MAINS SUPPLY

6

6. Connection Diagram

Connect the 3 core mains supply cable top the terminal 

block on the back box as follows: 

Live Supply (Brown or Red) to 

L

Neutral Supply (Blue or Black) to 

N

Earth (Green/Yellow) to 

For additional external (slave) lighting, connect the external 

load to the terminal block on the back box as follows: 

Live Supply (Brown or Red) to 

L

1

Neutral Supply (Blue or Black) to 

N

Earth (Green/Yellow) to 

Summary of Contents for LED100PIRBE

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 10W LED Slimline PIR Floodlight Single Flood Model LED100PIRBE Black Model LED100PIRWHE White...

Page 2: ...g when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be ea...

Page 3: ...time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 80mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max...

Page 4: ...movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of he...

Page 5: ...n the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plug...

Page 6: ...image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 l...

Page 7: ...erminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the t...

Page 8: ...e PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in th...

Page 9: ...owing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settin...

Page 10: ...time only by using the internal wall switch or circuit breaker Switch the internal wall switch twice OFF ON OFF ON within 2 seconds The floodlight will now illuminate continuously for 6 hours or until...

Page 11: ...responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching...

Page 12: ...csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support...