8. Lamp Adjustment

•  Pan/Tilt adjustment including details when using the optional spacer  

and corner brackets (sold separately).

9. Manual Override

•  The light can be switched ON for longer time periods by use of the Manual 

Override Mode. This can be activated at night time (only) by using the internal 
wall switch or circuit breaker. 

•  Switch the internal wall switch twice (OFF/ON, OFF/ON) within 2 seconds.  

The floodlight will now illuminate continuously for 6 hours, or until it is 
switched back into Auto Mode.

or

Thin flat head 
screwdriver

Knob Adjuster 
(Included in 
accessory pack)

If the unit starts to operate too late (i.e. when it is very dark).  
Adjust the control slightly clockwise. 

•  Continue to adjust until the unit operates as desired.

Summary of Contents for LED100PIRBE

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 10W LED Slimline PIR Floodlight Single Flood Model LED100PIRBE Black Model LED100PIRWHE White...

Page 2: ...g when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50Hz This luminaire is of class I construction and must be ea...

Page 3: ...time Back Box Mounting Centres 60mm IP55 Rated suitable for restricted external applications CE Compliant Dimensions H 160mm W 80mm D 50mm Other Loads External Slave LED Lamp Max 100W Halogen Lamp Max...

Page 4: ...movement directly TOWARDS See image C Therefore position the floodlight so that its PIR sensor looks ACROSS the likely approach path Avoid positioning the floodlight where there are any sources of he...

Page 5: ...n the wall using the back box as a template See image 4 Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plug...

Page 6: ...image 6 ensuring correct polarity is observed and that all bare conductors are sleeved See section 6 Connection Diagram for wiring details 5 8 Re connect the luminaire to the back box ensuring the 2 l...

Page 7: ...erminal block on the back box as follows Live Supply Brown or Red to L Neutral Supply Blue or Black to N Earth Green Yellow to For additional external slave lighting connect the external load to the t...

Page 8: ...e PIR sensor is set to Test Mode i e the TIME ON Adjustment to the minimum fully anti clockwise and the Lux Level set the Sun symbol fully clockwise We recommend using the knob adjuster included in th...

Page 9: ...owing activation and after all motion ceases Use a thin flat blade screwdriver to make adjustments We recommend using the knob adjuster included in the accessory pack to adjust the Time and Lux settin...

Page 10: ...time only by using the internal wall switch or circuit breaker Switch the internal wall switch twice OFF ON OFF ON within 2 seconds The floodlight will now illuminate continuously for 6 hours or until...

Page 11: ...responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent You are able to add an additional 6 hours ON time by switching...

Page 12: ...csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support...

Reviews: