3)
This product can be daisy-chained to a maximum of 500W.
2)
To connect the product:
• Twist the waterproof lock anti-clockwise and pull open the power connection carrier.
• Insert the power cable through the IP Gland.
• Lift the levers on the connectors and insert the live (brown) and neutral (blue) cable as shown.
• Tighten the IP Gland, re-insert the power connection carrier and tighten the waterproof lock clockwise.
4)
To daisy-chain the product:
• To access the output carrier, remove the plastic bung and screw in the supplied Cable Gland.
• Twist the waterproof lock anti-clockwise and pull open the power connection carrier.
• Insert the power cable through the IP Gland.
• Lift the levers on the connectors and insert the live (brown) and neutral (blue) cable as shown.
• Tighten the IP Gland, re-insert the power connection carrier and tighten the waterproof lock clockwise.
See Fig. 3.
Fig. 3
Fig. 4
L N
2*1.0mm²
press
Power
Max 500W
......