background image

W415-2890 / 03.27.20

47

  

information générale

FR

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTUR-
ER’S INSTRUCTIONS AND LOCAL BUILDING CODES. 

MINIMUM CEILING HEIGHT: 

7FT (2.13m)

HEARTH EXTENSION / FLOOR PROTECTION:

 MUST BE 

NON-COMBUSTIBLE AND EXTEND 22" IN FRONT OF THE INSERT 
AND 8" ON BOTH SIDES WITH A MINIMUM THICKNESS OF 1" 
(K=0.84)

CHIMNEY TYPE:

 MINIMUM 6” (152mm) DIAMETER APPROVED 

RESIDENTIAL TYPE. FOR MOBILE HOME, USE A CHIMNEY 
LISTED TO ULC S629 IN CANADA OR UL 103HT IN THE USA.

DO NOT OBSTRUCT SPACE UNDER HEATER.
SPECIAL METHODS ARE REQUIRED WHEN PASSING A CHIMNEY 
THROUGH A WALL OR CEILING. SEE INSTRUCTIONS AND 
BUILDING CODES.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE 
SERVING ANOTHER APPLIANCE.

WARNING:

FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT 

BURN ANY OTHER TYPE OF FUEL. 

DO NOT USE GRATE OR 

ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH.

WARNING:

 RISK OF SMOKE SPILLAGE. OPERATE ONLY WITH 

DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH CERAMIC GLASS.
DO NOT OVERFIRE. IF HEATER OR CHIMNEY CONNECTORS 
GLOW, YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY 
FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE 
CREOSOTE BUILD-UP MAY OCCUR RAPIDLY.

DANGER:

 RISK OF ELECTRICAL SHOCK. DISCONNECT POWER 

BEFORE SERVICING APPLIANCE.

INSERT:

 INSTALL AND USE ONLY IN SOLID FUEL BURNING 

FIREPLACES. DO NOT REMOVE BRICKS OR MORTAR FROM 
SOLID FUEL BURNING FIREPLACE. INSTALL WITH A POSITIVE 
FLUE CONNECTOR AND FACEPLATE.

CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS 
AND INSTALLATION INSPECTION IN YOUR AREA. 

A MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY 
CONNECTOR MAY BE REQUIRED BY THE AUTHORITY HAVING 
JURISDICTION.

POUR INSTALLATION ET UTILISATION CONFORM

ÉMENT AUX 

INSTRUCTIONS DU FABRICANT ET AUX CODES LOCAUX DU 
BÂTIMENT.

HAUTEUR DE PLAFOND MINIMAL:

 7PI (2,13m).

BASE DE PROTECTION/PROTECTION DE PLANCHER :

DOIT ÊTRE DE NATURE INCOMBUSTIBLE ET SE PROLONGER 
DE 22" À L’AVANT DE L’ENCASTRÉ ET 8" SUR LES CÔTÉS, ET 
AVOIR UNE ÉPAISSEUR MINIMALE DE 1" (K = 0,84).  

TYPE DE CHEMINÉE:

 DIAMÈTRE MINIMAL DE 6” (152mm) 

APPROUVÉE POUR USAGE RÉSIDENTIEL. POUR MAISON 
MOBILE, EMPLOYEZ UNE CHEMINÉE HOMOLOGUÉE ULC 
S629 AU CANADA OU UL 103HT AUX ÉTATS-UNIS.

NE RIEN ENTREPOSER SOUS L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT REQUISES LORSQU’UNE 
CHEMINÉE TRAVERSE UN MUR OU UN PLAFOND. VOIR LES 
INSTRUCTIONS ET LES CODES DU BÂTIMENT. 
NE PAS RACCORDER À LA CHEMINÉE D’UN AUTRE 
APPAREIL.

AVERTISSEMENT:

 POUR USAGE AVEC LE BOIS SEULEMENT. 

NE BRÛLEZ PAS AUCUNE AUTRE TYPE DE COMBUSTIBLE. 
N’UTILISEZ PAS DE CHENET OU NE SURÉLEVEZ PAS LE BOIS. 
PRÉPAREZ LE FEU DIRECTEMENT SUR L’ÂTRE.

AVERTISSEMENT: 

RISQUE D’ÉCHAPPEMENT DE FUMÉE. 

TENIR LA PORTE FERMÉE LORSQUE LE POÊLE 
FONCTIONNE. REMPLACEZ LA VITRE PAR UNE VITRE EN 
CÉRAMIQUE SEULEMENT. 
NE SURCHAUFFEZ PAS L’APPAREIL. SI L’APPAREIL OU LES 
RACCORDS ROUGEOIENT, L’APPAREIL SURCHAUFFÉE. 
INSPECTEZ ET NETTOYEZ LA CHEMINÉE FRÉQUEMMENT. 
DANS CERTAINES CONDITIONS, DES DÉPÔTS DE CRÉOSOTE 
PEUVENT SE FORMER RAPIDEMENT.

DANGER:

 RISQUE DE SECOUSSE ÉLECTRIQUE. DÉBRAN-

CHEZ AVANT DE PROCÉDER À L’ENTRETIEN.

ENCASTRÉ: 

INSTALLEZ ET UTILISEZ SEULEMENT DANS UN 

FOYER À COMBUSTIBLE SOLIDE. NE RETIREZ PAS DE 
MORTIER, NI BRIQUES DU FOYER À COMBUSTIBLE SOLIDE. 
INSTALLEZ AVEC UNE GAINE CONFORME ET UNE PLAQUE 
DE RECOUVREMENT.

RENSEIGNEZ-VOUS AUPR

ÈS DES AUTORITÉS LOCALES DU 

BÂTIMENT ET DU SERVICE DES INCENDIES AU SUJET DES 
RESTRICTIONS ET DES INSPECTIONS D’INSTALLATION DANS 
VOTRE RÉGION. 

UN DÉGAGEMENT MINIMAL DE 18” (457mm) JUSQU’AU 
RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR 
L’AUTORITÉ AYANT JURIDICTION.

W385-4534 / A

LISTED SOLID FUEL BURNING FIREPLACE INSERT

TESTED TO: / TESTÉ SELON : 

UL1482 - 2011 / ULC S628 - 1993

MODEL / MODÈLE: S20i / T20i

ENCASTRÉ À  COMBUSTIBLE SOLIDE HOMOLOGUÉ

CAUTION:

ATTENTION:

HOT WHILE IN OPERATION. DO NOT 
TOUCH. KEEP CHILDREN, CLOTHING AND 
FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.

QUAND L’APPAREIL FONCTIONNE, LA 
SURFACE DEVIENT CHAUDE. NE PAS 
TOUCHER. TENIR LES ENFANTS, LES 
VÊTEMENTS ET LES MEUBLES À 
L’ÉCART. LE CONTACT PEUT CAUSER 
DES BRÛLURES À LA PEAU.

E

F

WOLF STEEL LTD. 

24 NAPOLEON ROAD, 
BARRIE, ON, L4M 0G8 CANADA

NAC GUANGZHOU P.R.C.

NO.69 HEFENG ROAD, 
GUANGZHOU,CHINA

WOLF STEEL USA

103 MILLER DRIVE
CRITTENDEN, KY, 401030 USA

CLEARANCE TO COMBUSTIBLE CONSTRUCTION / DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES: 

(MEASURED TO APPLIANCE / À PARTIR DE L’APPAREIL)

APPLIANCE / 

APPAREIL

ADJACENT 
SIDE WALL 

(TO SIDE) / 

MUR LATÉRAL 

ADJACENT (AU 

CÔTÉ) 

A

MANTLE 

(TO TOP) / 
MANTEAU 

(JUSQU’AU 

DESSUS) 

B

TOP FACING 

(TO TOP) / 

HAUT DE LA 

FAÇADE 

(JUSQU’AU 

DESSUS) 

C

SIDE FACING (TO 

SIDE) / CÔTÉ DE 

LA FAÇADE (AU 

COTÉ) 

D

MINIMUM 

HEARTH 

EXTENSION / 

BASE DE 

PROTECTION 

MINIMALE 

E

MINIMUM 

HEARTH 

THICKNESS / 

ÉPAISSEUR 

MINIMALE DE LA 

BASE DE 

PROTECTION

F

MINIMUM 

HEARTH SIDE 

EXTENSION / 

BADE DE 

PROTECTION 

LATÉRALE 
MINIMALE 

G

S20i / T20i

8”

1”

22”

10”

22”

30”

16”

  

MANUFACTURE DATE: / DATE DE FABRICATION:

YEAR/ANNÉE:

2019

2020

2021

2022

MONTH/MOIS:

2023

2024

2

4

3

6

5

8

7

10

9

12

11

1

U.S. ENVIRONMENTAL PROTECTION AGENCY 

U.S. ENVIRONMENTAL PROTECTION AGENCY 

Certified to comply

Certified to comply

with 2020 particulate emission standards using cordwood. Certifié

with 2020 particulate emission standards using cordwood. Certifié
conforme à la norme d’émanation de particles de 2020 en utilisant

conforme à la norme d’émanation de particles de 2020 en utilisant
bois de corde. 

bois de corde. 40 CFR Part 60, Subpart AAA 

40 CFR Part 60, Subpart AAA 

2.25 Grams Per Hour / 

2.25 Grams Per Hour / 

2020 Cordwood / 2.25 Grammes par heure / Bois de Corde 2020. 

2020 Cordwood / 2.25 Grammes par heure / Bois de Corde 2020. 
Efficiency / Efficacité: 72% 

Efficiency / Efficacité: 72%  

S20i / T20i

THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND 
REPAIR FOR PROPER OPERATION. CONSULT THE OWNER’S 
MANUAL FOR FURTHER INFORMATION. IT IS AGAINST 
FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER 
IN A MANNER INCONSISTENT WITH THE OPERATING 
INSTRUCTIONS IN THE OWNER’S MANUAL. / CE POÊLE À 
BOIS DOIT ÊTRE INSPECTÉ PÉRIODIQUEMENT ET RÉPARÉ 
POUR UN FONCTIONNEMENT CORRECT. CONSULTEZ LE 
MANUEL DU PROPRIÉTAIRE POUR PLUS D’INFORMATIONS. IL 
EST CONTRE LE RÈGLEMENTS FÉDÉRAUX POUR FAIRE 
FONCTIONNER CE POÊLE À BOIS D’UNE MANIÈRE 
INCOMPATIBLE AVEC LES INSTRUCTIONS DE FONCTIONNE-
MENT DANS LE MANUEL DU PROPRIÉTAIRE.

NAC GUANGZHOU P.R.C.

NO.69 HEFENG ROAD, 
GUANGZHOU,CHINA

A

B

C

REFERENCE #: 161746

Cette illustration est à titre de référence 
seulement. Consultez la plaque d’homologation 
pour obtenir l’information précis.

La plaque d’homologation doit restée 
avec l’appareil à tout instant. Elle ne doit 
pas être enlevée.

note:

1.5 

information à propos de plaque d’homologation

ÉCHANTILLON

ÉCHANTILLON

ÉCHANTILLON

S LE BOIS. 

MÉE. 

ÊLE 

R UNE VITRE EN 

L’APPAREIL OU LES 

L SUR

ÉE FRÉQUEMMENT. 

ÉPÔTS DE CRÉOSOT

P

SECOUSSE ÉLECTRIQUE. DÉBRA

ÉDER À L

T UTILISEZ SEULEMEN

L

LIDE. NE RETIREZ P

I BRIQUES DU FOYER À COMBUS

Z AVEC UNE GAINE CONFORME 

COUVREMENT

SEIGNEZ-VOUS AU

S DES AU

BÂTIMENT ET DU SERVICE DES IN
RESTRICTIONS ET DES INSPEC
VOTRE RÉGION. 

UN DÉGAGEMENT MIN
RACCORD DE LA CHEM
L’AUTORITÉ AYANT J

N

N

N

N

N

N

N

N

N

N

N

N

N

N

AN

T

TT

HAN

HA

N

ÉC

CH

CLEARANCE TO COMBUSTIBL

(MEA

H

CH

APPLIAN

APPAREIL

JACENT 

SIDE WALL 

(TO SIDE) / 

MUR 

ADJAC

C

ÉCHA

YEA

S WOOD

R FOR P

F

F
IN A
INS

AN

N

Summary of Contents for T20i

Page 1: ...e materials may result in release of toxic fumes or render the appliance ineffective and cause smoke Do not let the appliance become hot enough for any part to glow red If the information in these ins...

Page 2: ...in hot for an extended period of time Any safety screen or guard removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This a...

Page 3: ...rn trash or garbage lawn clippings waste rubber waste petroleum products paints or paint thinners solvents plastic materials containing asbestos construction debris railroad ties or treated wood manur...

Page 4: ...peration 21 5 3 air control 22 5 4 fire extinguishers smoke carbon monoxide detectors 22 5 5 fuel loading 23 5 5 1 extended fire 24 5 6 smoking 24 6 0 maintenance 25 6 1 ash removal procedures 25 6 2...

Page 5: ...1 2 673mm 21 3 4 552mm 25 3 8 645mm 11 1 2 292mm 17 432mm 5 1 4 134mm 10 3 4 273mm A B 9 3 4 248mm 15 5 8 398mm 4 1 2 114mm 6 13 16 173mm 12 5 16 313mm C Due to an adjustable air channel A B and C ar...

Page 6: ...utput 12 944 54 127 BTU Hr Duration low fire 8 hours Weight w o bricks 225 lbs 102kg Weight of bricks 60 lbs 27kg Ideal wood length 16 406mm Minimum Stack Height 15 feet 4 5m Efficiency Standard B415...

Page 7: ...IS PROCESS DO NOT OVERFIRE THE APPLIANCE REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED WARNING All wiring should be done by a qualified electrician and sha...

Page 8: ...n flow freely up through the vent system and out into the atmosphere It is the correct balance of combustion air and the chimney vent system that will ensure the appliance provides you with its optimu...

Page 9: ...34 A LISTED SOLID FUEL BURNING FIREPLACE INSERT TESTED TO TEST SELON UL1482 2011 ULC S628 1993 MODEL MOD LE S20i T20i ENCASTR COMBUSTIBLESOLIDEHOMOLOGU CAUTION ATTENTION HOT WHILE IN OPERATION DO NOT...

Page 10: ...16 406mm B Mantel 30 762mm C Top facing 22 559mm D Side facing 10 254mm E Hearth front 22 559mm F Minimum hearth thickness 1 25mm G Hearth side 8 203mm H In front of insert 48 1219mm MINIMUM EXISTING...

Page 11: ...wn from attic spaces basements or above the roofing where other heating appliances or fans and chimneys exhaust or utilize air These precautions will reduce the possibility of appliance smoking or air...

Page 12: ...lation instructions above If a continuous liner is not installed a direct flue connection must be made The direct flue connection requires a non combustible connector that extends from the insert into...

Page 13: ...w within and around the appliance shall not be altered by the installation of the insert i e no louvres or cooling air inlet or outlet ports are blocked unless specifically tested as such for each fac...

Page 14: ...2 A B 1 With one hand on the door to prevent it from falling open the door and remove the 6 large screws located on the hinges Fig 4 1 2 Remove the door placing it face down on a soft non abrasive sur...

Page 15: ...pins clockwise or counter clockwise to raise or lower the opposite end of the door Tighten the set screw 3 Ensure the door latch closes and engages properly Door adjustment is strictly trial and erro...

Page 16: ...while the side with 2 holes on the end should face to the left Notch Holes Fig 4 4 Some parts hidden for clarity 1 With the appliance door open or removed insert the left side of the secondary air tu...

Page 17: ...s and one C brick along the back wall by pivoting the bricks up under the brick retainer D Carefully pivot fibre baffles D up onto the secondary air tubes as illustrated Fig 4 6 Ensure that the top ba...

Page 18: ...p A Fig 4 8 C Adjust the blower air channel by sliding it forwards or backwards Fig 4 9 D Fasten the blower air channel in place by installing 2 screws supplied Fig 4 10 4 7 logo placement Remove the...

Page 19: ...n a safety hazard and will void the warranty and certification Ensure that the blower s power cord is not in contact with any surface of the appliance to prevent electrical shock or fire damage Do not...

Page 20: ...nce is entirely hot it will burn very efficiently with little smoke from the chimney There will be a bed of orange coals in the firebox and secondary flames flickering just below the top baffles You c...

Page 21: ...ass and other components which may affect the overall appliance performance F Ensure an adequate draft to control burn rate and temperature See operation and maintenance sections 5 2 optional blower o...

Page 22: ...ey connectors or an uncontrollable burn which can lead to a chimney fire or permanent damage to the appliance Do not operate your appliance for longer than 30 minutes with the draft control on HIGH fu...

Page 23: ...y stacked wood burns quicker than a tightly packed load A flash fire is a small fire burned quickly when you don t need much heat After your kindling has caught load at least 3 pieces of wood stacked...

Page 24: ...or two hours C Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door A properly installed appliance should not smoke If yours does check the following Has...

Page 25: ...be retained in the closed container until all cinders have thoroughly cooled 6 2 creosote formation and removal WARNING Turn off the power before servicing the appliance Appliance may be hot Do not se...

Page 26: ...uate to ensure everyone s safety Call local fire department Have a fire extinguisher handy Contact local authorities for further information on how to handle a chimney fire After the chimney fire is o...

Page 27: ...n Be careful not to scratch the paint 2 Remove the 6 screws securing the glass retainers Fig 6 1 Set the screws and glass retainers aside 3 Remove all broken glass and the old gasket 4 Apply high temp...

Page 28: ...al authorized dealer distributor for complete cleaning instructions If the glass should ever crack or break while the fire is burning do not open the door until the fire is out Do not operate the appl...

Page 29: ...sing deflectors and lift them up Set screws and blowers attached to retainer aside D If dust and debris have accumulated vacuum the blowers and blower housing prior to re installation E If blower repl...

Page 30: ...d softwood burn equally well in this appliance but hardwood is denser will weigh more per cord and burn a little slower and longer Manufactured firelogs made by compressing 100 natural wood fibre can...

Page 31: ...replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance Instal...

Page 32: ...air 13 11 12 10 8 9 7 1 W200 0785 Cover primary air lower W325 0103 Handle front door W010 4597 Assembly blower W585 0949 Shield rear heat W010 4589 Assembly air control W485 0053 Spring adjustable ca...

Page 33: ...2 Blower replacement KB 35 Variable speed swtch W562 0002 SER Assembly door gasket W090 0339 Brick 2 250 x 9 000 x 1 250 E W090 0340 Brick 1 250 x 6 250 x 4 500 B W090 0341 Brick 1 250 x 2 625 x 9 000...

Page 34: ...W415 2890 03 27 20 EN 34 8 0 accessories Ref No Part Number Description Items may not appear exactly as illustrated 1 Stocked 1 SCH1B3041 One piece charcoal backerplate...

Page 35: ...nsufficient draft Add more pipe Not enough air Ensure air control is fully open Also ensure that the air opening is not obstructed Wood burns too fast Air control may need to be adjusted down Check to...

Page 36: ...s such as exhaust blowers furnaces clothes dryers etc Any damages to appliance combustion chamber heat exchanger or other components due to water weather damage long periods of dampness condensation d...

Page 37: ...EN W415 2890 03 27 20 37 11 0 notes...

Page 38: ...Produced and distributed by 24 Napoleon Road Barrie Ontario Canada L4M 0G8 Tel timberwolffireplaces com...

Page 39: ...ticules Br ler ces mat riaux pourrait entra ner la lib ration de fum es toxiques ou rendre l appareil inef cace et g n rer de la fum e Ne laissez pas l appareil chauffer au point o des parties devienn...

Page 40: ...afin d viter des br lures ou que leurs v tements ne s enflamment Surveillez attentivement les jeunes enfants lorsqu ils sont dans la m me pi ce que l appareil Les jeunes enfants et autres sont plus r...

Page 41: ...bois r sineux ou vert ou des bois durs fra chement coup s Br ler du bois vert ou humide peut causer des accumulations excessives de cr osote Lorsqu elle est allum e cette derni re peut causer un feu d...

Page 42: ...rie optionnelle 60 5 3 contr le d air 61 5 4 extincteurs et d tecteurs de fum e monoxyde de charbon 61 5 5 chargement de combustible 62 5 5 1 feu continue 63 5 6 enfumage 63 6 0 entretien 64 6 1 proc...

Page 43: ...2mm 25 3 8 645mm 11 1 2 292mm 17 432mm 5 1 4 134mm 10 3 4 273mm A B 9 3 4 248mm 15 5 8 398mm 4 1 2 114mm 6 13 16 173mm 12 5 16 313mm C En raison d un canal d air ajustable A B et C sont r glables dans...

Page 44: ...Hr Dur e combustion lente 8 heures Poids sans briques 225 lbs 102kg Poids des briques 60 lbs 27kg Longueur id ale de b ches 16 406mm Hauteur de tas minimum 15 pieds 4 5m Norme d ef cacit B415 1 10 A...

Page 45: ...cet appareil contactez les autorit s locales en b timent ou le service des incendies et votre compagnie d assurance a n de vous conformer leurs directives De la fum e non toxique manera de l appareil...

Page 46: ...n tirage ad quat Un bon quilibre entre l air comburant et le syst me d vacuation de la chemin e optimisera la performance de votre appareil L air secondaire p n tre par l ouverture arri re monte par l...

Page 47: ...LA CHEMIN E PEUT TRE EXIG PAR L AUTORIT AYANT JURIDICTION W385 4534 A LISTED SOLID FUEL BURNING FIREPLACE INSERT TESTED TO TEST SELON UL1482 2011 ULC S628 1993 MODEL MOD LE S20i T20i ENCASTR COMBUSTIB...

Page 48: ...te 30 762mm C Fa ade sup rieure 22 559mm D Fa ade lat rale 10 254mm E Base de protection avant 22 559mm F paisseur minimale de la base de protection 1 25mm G Base de protection c t 8 203mm H Devant de...

Page 49: ...reils de chauffage des ventilateurs et des chemin es vacuent ou tirent de l air Ces mesures r duiront les possibilit s de refoulement du fum e ou une inversion du d bit d air L entr e de la prise d ai...

Page 50: ...nada ci dessus Si une gaine continue n est pas install e un raccordement direct la buse de l appareil doit tre install Un raccordement direct la buse requiert qu un conduit incombustible soit install...

Page 51: ...L installation de l encastr ne doit pas modi er la circulation d air l int rieur ou autour de l appareil c d les persiennes la prise d air et la sortie d air doivent tre libres de toutes obstructions...

Page 52: ...rtement d utiliser deux personnes d enlever et ou installer la porte de l appareil parce qu elle est tr s lourde note 1 Avec une main sur la porte de la pr venir de tomber ouvrez la porte and retirez...

Page 53: ...porte Serrez la vis de pression 3 Assurez vous que le loquet de porte se ferme et s engage correctement Ajustement de la porte est par t tonnement strictement vous pouvez besoin d effectuer cet ajuste...

Page 54: ...ertes ou entrouvertes cr e un risque d incendie de chemin e ou du domicile Ne frappez pas et ne claquez pas la porte N enlevez jamais la porte lorsque l appareil est chaud Front View Back View Bouton...

Page 55: ...le chambre de combustion puis inserez une goupille fendue fournie Fig 4 4 4 pandez la goupille fendue pour xer le tuyau d air secondaire en place Les trois tuyaux d air secondaire l arri re sont insta...

Page 56: ...pouss s l arri re de la chambre de combustion en laissant un cart le long du mur un minimum de 1 po en taille Cela permettra les gaz du conduit d chapper la chambre de combustion Assurez vous que le j...

Page 57: ...air du souf erie en le glissez vers l avant ou vers l arri re Fig 4 9 D Fixez le canal d air du souf erie en place en installant 2 vis fournies Fig 4 10 4 7 emplacement de logo Retirez le papier dorsa...

Page 58: ...s chocs lectriques et les dommages caus s par le feu assurez vous que le cordon d alimentation de la souf erie n entre pas en contact avec quelconque surface de l appareil Ne faites pas passer le cord...

Page 59: ...grossi rement chiffonn s sur le plancher de l appareil et couvrez les de bois d allumage Ouvrez compl tement le contr le de combustion en le d placent compl tement droite Allumez le papier et laissez...

Page 60: ...o 51mm B Br lez seulement du vois sec avec moins de 20 d humidit et veillez ce que la porte vitr e reste propre C Un thermom tre de po le doit indiquer 350 F 176 C comme une temp rature moyenne D Lors...

Page 61: ...ut tre r gl pour passer d une combustion lente une combustion rapide en d pla ant la manette dedans et dehors Fig 5 2 Un tirage inad quat peut causer des refoulements de fum e dans la pi ce via l appa...

Page 62: ...es de fa on l che br leront plus rapidement que celles plac es serr es les unes contre les autres Un feu clair est un petit feu qui br le rapidement quand vous n avez pas besoin de beaucoup de chaleur...

Page 63: ...Si v tre fume v ri ez les points suivants Est ce que la chemin e a pu se r chauffer suf samment Est ce que le passage de la fum e est bloqu soit dans la chemin e soit dans le conduit de raccordement...

Page 64: ...ant m tallique jusqu ce qu elles aient compl tement refroidi 6 2 formation et enl vement de cr osote AVERTISSEMENT Coupez l alimentation lectrique avant de proc der l entretien de l appareil L apparei...

Page 65: ...eux pour assurer la s curit de chacun Appelez votre service d incendie Ayez un extincteur sous la main Contactez les autorit s locales pour savoir quoi faire en cas de feu de chemin e Apr s que le feu...

Page 66: ...ention de ne grattez pas la peinture 2 Retirez les 6 vis servant xer les supports du verre Fig 6 1 Mettez de c t les vis et les supports de verre 3 Retirez tout le verre briss et le joint d tanch it v...

Page 67: ...ctions de nettoyage compl tes Si la vitre devait ssurer pendant que le feu br le n ouvrez pas la porte jusqu ce que le feu s teigne et n utilisez pas l appareil jusqu ce que la vitre ait t remplac e p...

Page 68: ...s et les souf eries attach s au support D Si la poussi re et les d chets ont accumul s aspirez les souf eries et le bo tier de la souf erie avant de r installation E Si l entretien ou remplacement de...

Page 69: ...en que le bois r sineux dans cet appareil par contre le bois dur est plus dense plus lourd br le plus lentement et plus longtemps Les b ches arti cielles obtenues par la compression de bre de bois 100...

Page 70: ...sous garantie une photocopie de la facture originale sera requise afin de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et num ro de s rie...

Page 71: ...9 7 1 W200 0785 Couvercle air primaire inf rieur W325 0103 Poign e porte avant W010 4597 Assemblage souf erie W585 0949 Bouclier de chaleur arri re W010 4589 Assemblage contr le d air W485 0053 Resso...

Page 72: ...remplacement KB 35 Interrupteur de vitesse variable W562 0002 SER Ensemble joint d tanch it de porte W090 0339 Brique 2 250 x 9 000 x 1 250 E W090 0340 Brique 1 250 x 6 250 x 4 500 B W090 0341 Brique...

Page 73: ...W415 2890 03 27 20 73 FR 8 0 accessoires R f No de Partie Description Ces articles peuvent diff rer de ceux illustr s 1 En Stock 1 SCH1B3041 Contour d une pi ce en charbon...

Page 74: ...ez d air Assurez vous que le contr le d air est compl tement ouvert Assurez vous que le contr le d air n est pas obstru e Le bois br le trop rapidement Le contr le d air doit possiblement tre r duit A...

Page 75: ...s pressions n gatives qui peuvent ou non tre caus s par des syst mes m caniques tels que les ventilateurs d vacuation les fournaises les s che linge etc Le nettoyage r gulier de la ne cendre g n r e d...

Page 76: ...ProduJUT FU EJTUSJCV T QBS 24 Napoleon Road Barrie Ontario Canada L4M 0G8 T l timberwolffireplaces com...

Reviews: