1. The water heater is designed to be connected to 220V~ single-phase
electric main. Prior to connecting make sure that parameters of the electric
main in the place of connection correspond to parameters, specified on the
identification plate with technical parameters of the appliance. You should
follow the current electrical safety code when installing the water heater.
2. The power outlet must be properly grounded. The outlet must be
designed for rated current not less than 10A, electric cable with copper
core must have cross section not less than 3x1.5 mm
2
(for copper).
The power outlet and plug must always be dry to prevent current leakage.
Regularly check if the power plug is tightly connected to the outlet. Do
it in the following order: insert the power plug into the outlet, switch off
the water heater after half-hour operation and unplug the cord, check if
the plug is heated by your hand. If the plug is heated over 50°C, then to
prevent damages, accidents and fire as a result of bad electrical contact,
replace the outlet with a new one. A specialist must do this.
1. At first, open one of the separable taps at the water heater outlet, then
open the inlet tap. The electric water heater will start filling with water.
When water flows from separable tap freely, it means the water heater is
fully filled with water and you can close the separable tap.
2. Plug the power cord into the outlet.
Connection to electric main
IMPORTANT!
If water in the installation location contains a large
amount of calcium, manganese or iron salts, then
necessary to mount a respective filter in the delivery
system to reduce the amount of scale generated in
the tank and on the heating element.
IMPORTANT!
Prior to connecting the tank water heater, make sure
that the water heater is properly grounded. Proper
grounding is important to minimize electric shocks
and risk of fire. The power cord is equipped with a plug
with a grounding pin. The appliance must be used
with a properly grounded power outlet. If the outlet,
you are intending to use, is not properly grounded or
grounded by a time-delay fuse or a circuit breaker,
contact a qualified electrician to install a proper outlet.
IMPORTANT!
To provide reliable operation and safe use of the
water heater, prior to the first run check if it is properly
connected to the 220V~ AC mains. The water heater to
be connected must be securely linked with the earth
circuit of your electric mains. The waterheater must be
grounded properly, otherwise it is extremly dangerous
for life safety.