ENGLISH
5. Water heater with the mounted valve must be connected to the water
main install a shut-off valve at the water inlet point.
6. Connect the desired number of consumption points to the outlet nozzle,
marked red.
7. Check leak integrity of joints: open the shut-off cock and one of the cock
assemblies. After the tank is filled with water, as evidenced by issue of water
from the cock assembly, shut the cock assembly and check the leak integrity
of all joints.
IMPORTANT!
If water in the installation location contains a large amount of
calcium, manganese or iron salts, then necessary to mount a
respective filter in the delivery system to reduce the amount of scale
generated in the tank and on the heating element.
Connection to electric main
IMPORTANT!
Prior to connecting the tank water heater, make sure that the water
heater is properly grounded. Proper grounding is important to
minimize electric shocks and risk of fire. The power cord is equipped
with a plug with a grounding pin. The appliance must be used with a
properly grounded power outlet. If the outlet, you are intending to
use, is not properly grounded or grounded by a time-delay fuse or a
circuit breaker, contact a qualified electrician to install a proper
outlet.
1. The water heater is designed to be connected to 230V single-phase
electric main. Prior to connecting make sure that parameters of the electric
main in the place of connection correspond to parameters, specified on the
identification plate with technical parameters of the appliance. You should
follow the current electrical safety code when installing the water heater.
2. Power outlet must be designed for rated current not less than 10A, copper
stranded power cord not less than 3 x 1.5 mm2 in cross section (for copper).
3. The power outlet and the plug must always remain dry to prevent
current leakage. Regularly check if the power plug is tightly connected to
the outlet. Do it in the following order: insert the power plug into the
outlet, switch off the water heater after half-hour operation and unplug
the cord, check if the plug is heated by your hand. If the plug is heated over
50°C, then to prevent damages, accidents and fire as a result of bad
electrical contact, replace the outlet with a new one. A specialist must do
this.
4. Power cord of the appliance is a single unit with GFCI (Ground Fault
Circuit Interrupter).
IMPORTANT!
To provide reliable operation and safe use of the water heater,
prior to the first run check if it is properly connected to the 220V
AC mains. The water heater to be connected must be securely
linked with the earth circuit of your electric mains. If the water
heater is not grounded, then in case of a short circuit GFCI,
supplied with the heater, may not operate. It is dangerous.
1. Connect the cable to the mains, indicator (1) will light up.
2. Press button (2) for testing, voltage will be cut off, indicator (1) will
light down and restart button (3) will go upwards.
3. Press button (3) to restart the appliance, voltage will be restored and
indicator (1) will light up.
GFCI (Ground Fault Circuit Interrupter) (Fig. 11)
Fig
.
11
GFCI operation indicator light (1)
TEST button (2)
Restart button (3)
9
www.timberk.
storage water heater
com
electrical
Summary of Contents for SWH MS210H
Page 22: ...5 6 7 1 230 2 10A 2 3 1 5 50 3 230 1 1 2 2 1 3 3 3 1 11 11 22 www timberk com ...
Page 28: ... Timberk Timberk www btpart ru www timberk com Timberk 28 www timberk com ...
Page 29: ...29 www timberk com RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 ...
Page 31: ...www timberk com ...
Page 32: ...www timberk com ÀÂ71 ...