Page 1: ...0 H SWH RS2 80 H SWH RS7 30 V SWH RS7 40 V SWH RS7 50 V SWH MS2 10 H RS1 RS1 series Electrical storage water heater Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices SWH MS2 10H SWH MS2 10H series RS7 RS7 series RS2 RS2 series ...

Page 2: ... Water heater installation Location Water heater mounting methods Water heater mounting Connection to water main Connection to electric mains Ground Fault Circuit Interrupted GFCI Water heater control Water heater operation Maintence Troubleshooting Wiring diagram Disposal 1 2 3 4 5 6 7 8 9 10 11 12 www timberk electrical storage water heater com ...

Page 3: ...t specified by this operation manual 17 Do not use the water heater in an explosive or corrosive environment Do not store gas and other volatile flammable liquids next to the appliance it is very dangerous 18 It is forbidden to make alterations in the design of the water heater or modify it 19 Any service operations must be performed by a specialized organisation and qualified specialists Improper...

Page 4: ...s water heater in mm according to Fig 1 are given below in Table 2 Table 2 MS2 series 232 220 470 D 100 E 147 5 Capacity l 10 Fig 1 A B C D E 230 230 230 8 7 8 7 8 7 2000 2000 2000 50 80 100 0 7 0 7 0 7 IP 4 IP 4 IP 4 230 30 2000 8 7 IP 4 Ø345 606 7 0 7 18 38 57 71 Ø345 865 Ø410 945 Ø410 1100 8 93 13 5 14 7 230 30 2000 8 7 IP 4 Ø345 606 7 230 230 8 7 8 7 2000 2000 50 80 0 7 0 7 0 7 IP 4 IP 4 18 38...

Page 5: ...s water heater in mm according to Fig 3 are given below in Table 4 Table 4 RS1 seies RS2 seies 608 614 624 356 180 180 D D 343 343 E E 8 8 F F 122 5 178 848 864 864 356 310 310 343 343 8 8 122 5 178 858 890 1003 1058 874 426 1020 426 425 425 570 570 411 411 411 411 8 8 8 8 158 5 213 5 158 5 213 5 Capacity l Capacity l 30 30 50 50 80 80 100 100 4 WATER HEATER DESCRIPTION Fig 2 Fig 3 A B C D F 100 E...

Page 6: ... where the electric water heater is to be mounted must withstand at least the double weight of the water heater fully filled with water there must be no cracks and other damages on the wall Otherwise it is necessary to take measures to strengthen the mounting or mount the waterheateronaspecialsupport 3 If a bathroom is too small the water heater can be installed elsewhere unexposed to direct sunli...

Page 7: ...Vertical position RS2 MS2 Horizontal position 11 12 1 power cord with a plug and GFCI 2 mounted water heater 3 composite pressure safety valve 4 cold water inlet tap 5 mixer 6 shower header 7 water main shut off valve 8 discharge pipe 9 water main 10 tub 11 T bend 12 magnesium anode nozzle for water discharge for RS2 series not included in the scope of delivery depending on the product batch GFCI ...

Page 8: ...ts turn the hook upwards securely tighten nuts and then hang the electric water heater on these hooks forRS1 RS2 RS7series seeFig 10a NOTE In places or on the wall where there may be a water contact the power outletinstallationheightmustbenotlessthan1 8m Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa pressure maximum pressure is 0 7 MPa NOTE The water h...

Page 9: ...he appliance You should followthecurrentelectricalsafetycodewheninstallingthewaterheater 2 Power outlet must be designed for ratedcurrent not less than 10A copper strandedpowercordnotlessthan3x1 5mm2incrosssection forcopper 3 The power outlet and the plug must always remain dry to prevent current leakage Regularly check if the power plug is tightly connected to the outlet Do it in the following or...

Page 10: ...voltage is not restored and or indicator 1 doesn t light up it means that the water heater is not operating properly In both cases disconnect the water heater and call the service center to reduce the risk of an electric shock do not disassemble remove or fillliquidinthisappliance maximum power I 2000 W Control panel for the following models SWH RS2 30 H SWH RS2 50 H SWH RS2 80 H Switch Thermostat...

Page 11: ...ntinuous hot water supply is provided When the water heater automatically switches off the indicator light goes out 4 If you will turn the thermostat handle clockwise you ll increase the temperature of heating Maximum temperature inside inner tank is 75 C approx If you want to reduce the temperature of water please turn the handle anticlockwise IMPORTANT Power outlet must be designed for rated cur...

Page 12: ...tclicks Fig 16 ifthebuttoncannotbepressedandthereisnoclicking thenyoushould waituntilthethermalswitchcoolsdowntotheinitialtemperature innertank 3 To ensure long reliable water heater operation it is recommended to regularly clean the internal tank and remove deposits on the electric heating element of the water heater as well as check condition fully decomposed or not of the magnesium anode and if...

Page 13: ... de energize the water heater cut off water supply and contact your local Timberk Authorized Service Center for a consult or repair of the appliance IMPORTANT Neverdrainwaterifitstemperatureisover50 Csinceitmayresultin burns 1 Temperature adjustment device is broken 2 Temperature limiter was actuated or was not switched on 3 Temperature limiter is broken 1 Water feed is cut off 2 Water pressure is...

Page 14: ...to use the water heater carefully do not switch between modes abruptly closely follow recommendations set forth in this operation manual Children nearby the fan heater must be supervised by adults and must never use the unit playing games GUARANTEE CARD IS ENCLOSED IN THE PRODUCT PACKAGE NOTE Technicalandanyothercharacteristicsoftheappliancecanberevised Such changes may be introduced without warni...

Page 15: ...ENGLISH 1 imberk imberk 1 2 3 4 5 6 7 8 9 10 11 12 13 15 15 16 16 16 18 19 19 19 20 21 21 22 22 23 24 25 26 26 27 27 2 1 2 15 www timberk com ...

Page 16: ...3 230 50 4 5 6 7 8 9 10 11 12 13 14 75 15 16 17 18 19 3 1 2 3D Logic DROP Defense SHOCK Defense HOT Defense 3 4 NON CFC 5 6 SUS 304 1 2 7 16 www timberk com ...

Page 17: ...38 57 Ø345 865 Ø410 945 SWH RS2 30 H SWH RS2 50 H SWH RS2 80 H 8 93 13 5 1 1 230 5 2 1200 10 0 7 IP 4 10 25º Ø220 430 SWH MS2 10 H 3 8 MS2 1 2 2 MS2 232 220 470 D 100 E 147 5 10 1 A B C D E 230 8 7 2000 0 7 IP 4 SWH RS7 30 V SWH RS7 40 V SWH RS7 50 V 230 8 7 2000 0 7 IP 4 230 8 7 2000 0 7 IP 4 17 30 40 50 23 9 4 33 11 6 43 13 6 Ø290 750 Ø290 950 Ø290 1160 I I I I I I I I I I I 372 3 430 7 532 9 61...

Page 18: ... 848 864 864 356 310 310 343 343 8 8 122 5 178 858 890 1003 1058 874 426 1020 426 425 425 570 570 411 411 411 411 8 8 8 8 158 5 213 5 158 5 213 5 30 30 50 50 80 80 100 100 4 2 3 A B C D F 100 E C A E B D F A B C D F 100 E 4 RS7 4 5 5 RS7 750 758 320 D 298 E 14 F 77 5 950 958 450 298 14 77 5 1160 1168 600 298 14 77 5 30 40 50 18 100 www timberk com ...

Page 19: ...RS1 RS7 7 1 2 3 4 5 6 7 8 9 10 11 7 1 2 3 4 5 6 7 8 9 10 11 6 1 2 3 5 1 1 2 2 3 1 4 1 5 1 6 1 7 1 8 1 RS1 RS2 RS7 MS2 6 1 2 3 5 6 7 8 9 4 S2 6 1 2 3 4 5 6 7 8 9 10 11 19 11 10 www timberk com ...

Page 20: ... 8 8 1 2 3 4 5 6 7 8 9 9 11 12 RS1 RS7 RS1 RS7 5 6 7 RS1 RS7 RS2 MS2 1 2 3 4 5 6 7 8 9 10 RS2 11 12 20 13 14 www timberk com ...

Page 21: ... S2 RS2 0 6 10 1 2 1 8 1 0 1 0 7 0 7 0 7 2 G1 2 3 4 10 9 10 11 12 Rs2 13 14 RS1 RS2 RS7 10 MS2 10 3 230V 10A 21 www timberk com ...

Page 22: ...5 6 7 1 230 2 10A 2 3 1 5 50 3 230 1 1 2 2 1 3 3 3 1 11 11 22 www timberk com ...

Page 23: ...7 I 2000 SWH RS1 30 V SWH RS1 50 V SWH RS1 80 V SWH RS1 100 V 12 2 1 3 1 I 2000 SWH RS2 30 H SWH RS2 50 H SWH RS2 80 H 13 SWH RS7 30 V SWH RS7 40 V SWH RS7 50 V 14 23 www timberk com ...

Page 24: ...C RS1 RS2 MS2 1 open 2 3 4 75 5 Optimum SWH MS2 10H 58 2 10 3 1 5 SWH MS2 10 H 15 24 10 3 1 5 C RS7 1 open 2 Timberk 3 NORMAL 1200 ENERGY SAVE 800 EXPRESS HEAT 2000 4 5 6 75 7 Optimum 58 2 www timberk com ...

Page 25: ...9 16 18 17 1 2 0ºC 3 4 5 MS2 RS2 17 RS1 RS7 18 www timberk ru Timberk 25 8 HEATING 9 Timberk www timberk com ...

Page 26: ...7 14 50 6 RS2 16 8 11 19 2 RS7 10 6 1 2 3 Timberk Timberk Timberk Timberk Timberk Timberk 26 www timberk com ...

Page 27: ... 115162 28 4 74956044266 74956044266 P 60335 2 35 2000 P51318 14 1 2006 4 P51318 14 2 2006p 5 7 P51317 3 3 2008 P51317 3 2 2006p 6 7 RUC IL AB71 B 00051 09 02 2012 08 02 2015 Timberk Timberk 10 88000 972 8 637 88 311 111024 5 2 1 74996537356 7 495 6275285 www timberk com ...

Page 28: ... Timberk Timberk www btpart ru www timberk com Timberk 28 www timberk com ...

Page 29: ...29 www timberk com RU Timberk Timberk KZ AK BY OS TJ UA KG CIS c 10 ...

Page 30: ...30 www timberk com www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com ...

Page 31: ...www timberk com ...

Page 32: ...www timberk com ÀÂ71 ...

Reviews: