1.  Important information
2.  Precautions
3.  Application of water heater
4.  Performance parameters

Technical characteristics
Dimensional features

5.  Water heater description
6.  Delivery set
7.  Water heater installation

Location
Water heater mounting methods
Water heater mounting
Connection to water main
Connection to electric mains
Ground Fault Circuit Interrupter(GFCI)

8.  Water heater control

Control panel
Water heater operation

9.  Maintenance
10.  Troubleshooting and error codes
11.  Transportation and storage conditions
12.  Wiring diagram
13.  Disposal
14.  Serial number and production date

2
3
3
3
4
5
5
6
7
7
7
8
9
9

10
11
11
11
12
13
13
14
14
14

Dear customer!

Thank you for your good choice. You purchased TIMBERK 

electric storage water heater with an stainless steel internal 

tank. It will serve you for a long time!

TIMBERK electric storage water heaters will provide a lot 

of hot water and will automatically maintain the specified 

temperature. They are perfect to provide hot water for country 

houses, cottages, baths and other standalone amenity rooms.

Please, read this operation manual carefully prior to use of the water heater.
This operation manual contains important information regarding your 

safety, as well as recommendations on the proper operation of the unit and 

its maintenance.
Save this operation manual together with the guarantee card, cash register 

receipt, if possible, cardboard box and packing material.
Different types of this device are described in this manual.
The purchased water heater can slightly differ from the one, described in 

the manual, but that doesn’t affect methods of its use and operation.

IMPORTANT! 

Important precautions and instructions, contained in 

this manual, do not account for all possible modes and 

situations to be encountered. It is vital to understand 

that common sense, caution and thoroughness are the 

factors that are impossible to be built-in in any product. 

These factors must be taken into consideration by 

a person, interested in proper operation of the unit. 

The manufacturer does not bear any responsibility in 

case when the unit or its parts are damaged during 

transportation, as a result of improper installation, 

voltage fluctuations, as well as if some part of the unit 

was altered or modified.

1. IMPORTANT INFORMATION

TABLE OF CONTENTS

1. Completely automatic control: automatic water heating, continuous auto-

matic water temperature control.
2. 

DROP Defense

 – leakage protection and protection against surplus pres-

sure within a tank (pressure safety valve).

HOT Defense

 – two-stage overheating protection (thermostat and tempera-

ture limiter).
ALL PROTECTION SYSTEMS ARE RELIABLE AND SAFE.
3. Pipes of heating elements are designed taking into account high heat load: 

safe and reliable, with an increased service life.
4. NON CFC urethane foam insulation of increased thickness: excellent heat 

A number of precautions is to be observed upon operation of the fan heat-

er. Improper operation as a result of ignoring precautions may harm health 

of the user and other people, as well as damage their property.
1. Any electrical appliance must be supervised when in operation, espe-

cially if there are children nearby. Make sure children do not touch the ap-

pliance.
2. Prior to installing the water heater, not connecting it to electrical main, 

check and make sure the outlet for the  water heater has a ground pin and 

if it is properly earthed. If there is no earth circuit in your electrical main then 

operation of the water heater is dangerous for your life.
3. Connect the water heater only to 220-230V, 50Hz main. If necessary, 

find out parameters of your mains at power suppliers.
4. To prevent overheating and risk of fire, as well as damage of internal 

electrical main, do no modify the power cord’s length and do no connect 

the water heater through electrical extenders.
5. It is forbidden to switch on the water heater if it is not filled with water or 

if water cannot go through a pressure safety valve.
6. Never use the water heater if it is broken.
7. Do not remove the water heater cover when it is in operation.
8. Immediately unplug the water heater from electrical main if strange 

sounds, odor or smoke are coming from it.
9. Always unplug the water heater from electrical main during a thunder-

storm.
10. Prior to cleaning and maintenance of the water heater unplug it from 

electrical main. Cleaning and maintenance must be performed in compli-

ance with instructions of this operation manual.
11. Do not use hazardous chemical substances to clean the water heater 

and prevent their contact with the appliance.
12. To prevent electrical shock the damaged power cord must be replaced 

only in manufacturer’s authorized service centers by qualified specialists.
13. To prevent electrical shock do not place the power cord nearby heating 

devices and flammables or combustibles.
14. Do not press buttons on the control panel of the water heater and its 

remote controller (for some models) otherwise but by your fingers.
15. Since temperature of water in the water heater can reach +75°C, when 

it is in operation you should not place your body parts under hot water at 

2. PRECAUTIONS

the first run.
To prevent burns you should adjust the temperature of the discharging 

water.
16. Do not use the water heater for purposes not specified by this oper-

ation manual.
17. Do not use the water heater in an explosive or corrosive environment. 

Do not store gas and other volatile flammable liquids next to the appliance 

– it is very dangerous!
18. It is forbidden to make alterations in the design of the water heater or 

modify it.
19. Any service operations must be performed by a specialized organisa-

tion and qualified specialists. Improper installation may cause voiding of 

guarantee maintenance.
20. The water heater is not intended for use by children and persons with 

reduced physical, sensory or mental capabilities, or a lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by an individual responsible for their safe-

ty. Children should be supervised to ensure that they do not play with the 

appliance.

3. APPLICATION OF WATER HEATER

Electric water heater is used to heat cold water from water supply. Unit is 

for household use.

4. PERFORMANCE PARAMETERS

Summary of Contents for SWH FSM3 100 V

Page 1: ... H SWH FSM6 80 H SWH FSM6 100 H SWH FSM3 30 V SWH FSM3 50 V SWH FSM3 80 V SWH FSM3 100 V SWH FSM4 30 H SWH FSM4 50 H SWH FSM4 80 H SWH FSM4 100 H Electrical storage water heater Outlook of devices aslo colour scores can be revised without any special advance notices Производитель вправе менять внешний вид прибора и цветовую гамму при бора без специального уведомления FSM5 FSM6 FSM3 FSM4 ...

Page 2: ...ons may harm health of the user and other people as well as damage their property 1 Any electrical appliance must be supervised when in operation espe cially if there are children nearby Make sure children do not touch the ap pliance 2 Prior to installing the water heater not connecting it to electrical main check and make sure the outlet for the water heater has a ground pin and if it is properly...

Page 3: ...7 8 7 8 7 8 7 Rated power W 2000 2000 2000 2000 Stage power W 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Tank capacity L 30 50 80 100 Rated pressure Mpa 0 7 0 7 0 7 0 7 Water protection class IPX4 IPX4 IPX4 IPX4 Heating time at Δ 30 ºC min 28 46 73 80 Appliance dimensions mm 550x435x238 855x435x238 991x493x270 1190x493x270 Weight kg 9 8 13 4 18 9 23 4 Factual year energy consumption k...

Page 4: ... 5 heating element 6 right composite protective cover 7 temperature sensor case 8 composite pressure safety valve be sure to install onto the cold water supply tube Pos A 9 emergency discharge of surplus water pressure a small water leakage is possible from the emergency discharge hole when the water heater is operating It is normal 10 inlet nozzle with a splitter 11 hot water outlet nozzle 12 eme...

Page 5: ...umber of consumption points to the outlet nozzle marked red 7 Check leak integrity of joints open the shut off cock and one of the cock assemblies After the tank is filled with water as evidenced by issue of water from the cock assembly shut the cock assembly and check the leak integrity of all joints Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa press...

Page 6: ... connected to the outlet Do it in the following order insert the power plug into the outlet switch off the water heater after half hour operation and unplug the cord check if the plug is heated by your hand If the plug is heated over 50 C then to prevent damages accidents and fire as a result of bad electrical contact replace the outlet with a new one A specialist must do this 3 Power cord of the ...

Page 7: ... used to activate timer and night heating 8 button It is used to increase the selected value 9 MODE button It is used to set time and timer 1 Time indication 2 Timer activation indicator It lights up when water heater on off timer is activated 3 Energy save indicators They light up when selecting low heating power 800 W 4 Water heater water temperature indicator 5 Mode button It is used to set tim...

Page 8: ...night heating at that indicator on the display will light up 6 2 Press timer button twice again to deactivate night heating at that indicator on the display will light down 7 Timer and night heating Timer and night heating can be activated simultaneously For this purpose it is necessary to press timer button several times until timer and night heating indicators light up simultaneously 8 Control p...

Page 9: ...h Water temperature control system is damaged Contact a repairer TIMBERK service center Water leakage Seal at the point of pipe connection is broken Replace the joint seal Water flows from the appliance s case Breaking of the internal tank corrosion Seal at the point of the heating element connection is broken Contact a repairer TIMBERK service center Failure Cause Troubleshooting method E1 Dry he...

Page 10: ...нтура в вашей электросети эксплуатация водонагревателя опас на для жизни 3 Подключайте водонагреватель только к сети 230В 50Гц При не обходимости выясните характеристики своей сети у поставщиков электроэнергии 4 Во избежание перегрева и риска возникновения пожара а также повреждения внутренней электрической сети не изменяйте длину сетевого шнура и не подключайте водонагреватель через электри чески...

Page 11: ...0 230 50 Номинальная сила тока A 8 7 8 7 8 7 8 7 Номинальная потребляемая мощность Вт 2000 2000 2000 2000 Мощность по ступеням Вт 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Объем л 30 50 80 100 Номинальное давление МПа 0 7 0 7 0 7 0 7 Класс влаго защиты IPX4 IPX4 IPX4 IPX4 Класс защиты I I I I Время нарева при Δ 30 ºC мин 28 46 73 80 Размеры прибора мм 550x435x238 855x435x238 991x493x...

Page 12: ...лектрический водонагреватель следует устанавливать на прочной стене 2 Стена на которой устанавливается электрический водонагрева тель должна выдерживать как минимум двойной вес водонагрева теля полностью заполненного водой на стене должны отсутствовать трещины и другие повреждения В противном случае необходимо при нять меры для усиления крепления или установить водонагреватель на специальной опоре...

Page 13: ...керные болты следует преду смотреть свободное пространство между нижней частью водонагревателя и полом не менее 0 6 м а для серии FSM6 FSM4 ещё и свободное про странство между боковой крышкой с правой стороны и стеной для обеспечения удобства тех нического обслуживания при необходимости его проведения Монтаж водонагревателя 1 Электрический водонагреватель следует устанавливать на проч ной стене Ес...

Page 14: ...роверку проводите в следующем порядке вставьте электрическую вилку в розетку через полчаса работы выключите водонагреватель и вынь ВНИМАНИЕ Перед подключением накопительного водона гревателя убедитесь в том что водонагреватель заземлен надлежащим образом Правильное за земление важно для минимизации ударов током и опасности возгорания Шнур питания оснащён вилкой с контактом заземления Устройство до...

Page 15: ...ньшаете температуру нагрева воды 3 4 Водонагреватель автоматически поддерживает температуры воды Когда температура воды внутри водонагревателя достигает установленной пользователем температуры нагрев автоматически выключается при этом на панели управления светится только инди катор питания голубого цвета Когда температура воды внутри водонагревателя понижается ниже установленного уровня нагрев авт...

Page 16: ...лятора против часовой стрелки от по зиции max к позиции min или нажмите кнопку чтобы умень 3 Выбор режима мощности 3 1 Нажмите на ручку терморегулятора на панели управления несколь ко раз или на соответствующие кнопки на ПДУ чтобы выбрать необхо димую мощность нагрева 3 2 При выборе низкой мощности нагрева на панели управления за гораются индикаторы energy save а на дисплее отображается инди катор...

Page 17: ...тся рядом с ТЭНом имеет круглую форму рис 14 для вертикальных водонагревателей серии FSM5 FSM3 нажать до щелчка кнопку расположенную по центру термовыключателя рис 15 если кнопка не нажимается и нет щелчка то подождать пока термо 6 Чтобы правильно слить воду из внутреннего бака надо восполь зоваться сливным отверстием только для серии FSM6 FSM4 надо открутить заглушку закрывающую сливное отверстие...

Page 18: ...ие электросхемы изделия которое может быть выполнено без уведомления потребителя По окончании срока службы водонагреватель следует утилизировать Подробную информацию по утилизации водонагревателя Вы можете получить у представителя местного органа власти Срок службы во донагревателя составляет 15 лет 13 УТИЛИЗАЦИЯ Серийный номер изделия месяц и год изготовления указаны в со ставе ID LINE кода издел...

Page 19: ...ей техники Timberk мы дополнительно сообщаем что русский является государствен ным языком в следующих госу дарствах в Российской Федерации в Республике Беларусь наряду с белорусским языком в частично признанной Южной Осетии наряду с осетинским языком Русский язык является офици альным языком во всех случаях другой язык или другие языки выступают как государствен ный или второй официальный в следую...