Control panel of FSM3/FSM4series

1. Thermostat handle

Please, use this handle to set the desired temperature of water. Turning the

knob in a clockwise direction you increase temperature of water.

2. Heating mode switcher

«      » - means OFF position. Turning the knob in a clockwise direction you 

increase power from 800W up to 2000W

3. Indicators lighting

If light are blue it means the water heater works, but heating element is 

off. If lights are blue and red simultaneously  it means the heating element 

heats a water inside tank.

Water heater operation (FSM3/FSM4 series)

1. Switching on

1.1 At first, open one of the hot water outlet valves, then open the cold 

water supply valve. The electric water heater will start filling with water. 

When water flows from the hot tap freely, it means the water heater is fully 

filled with water and you can close the hot water outlet valve.

8. WATER HEATER CONTROL

Connection to electric main

IMPORTANT! 

Prior to connecting the tank water heater, make sure 

that the water heater is properly grounded. Proper 

grounding is important to minimize electric shocks 

and risk of fire. The power cord is equipped with a plug 

with a grounding pin. The appliance must be used 

with a properly grounded power outlet. If the outlet, 

you are intending to use, is not properly grounded or 

grounded by a time-delay fuse or a circuit breaker, 

contact a qualified electrician to install a proper outlet.

IMPORTANT! 

To provide reliable operation and safe use of the 

water heater, prior to the first run check if it is properly 

connected to the 230V AC mains. The water heater to 

be connected must be securely linked with the earth 

circuit of your electric mains. If the water heater is 

not grounded, then in case of a short circuit GFCI, 

supplied with the heater, may not operate. It is 

dangerous.

IMPORTANT! 

Wall outlet should be rated on voltage not lower than 

10А, electric main cabel with cooper section not 

lesser then 3х1,5 mm

2

 (for cooper).

Electric  plug of  the device corresponds one block 

with GFCI.

1. The water heater is designed to be connected to 230V single-phase 

electric main. Prior to connecting make sure that parameters of the electric 

main in the place of connection correspond to parameters, specified on the 

identification plate with technical parameters of the appliance. You should 

follow the current electrical safety code when installing the water heater.
2. The power outlet must be properly grounded. The outlet must be 

designed for rated current not less than 10A. The power outlet and plug 

must always be dry to prevent current leakage. Regularly check if the 

power plug is tightly connected to the outlet. Do it in the following order: 

insert the power plug into the outlet, switch off the water heater after half-

hour operation and unplug the cord, check if the plug is heated by your 

hand. If the plug is heated over 50°C, then to prevent damages, accidents 

and fire as a result of bad electrical contact, replace the outlet with a new 

one. A specialist must do this.
3. Power cord of the appliance is a single unit with GFCI (Ground Fault 

Circuit Interrupter).

GFCI (Ground Fault Circuit Interrupter) (Fig. 9)

1. Connect the cable to the mains, indicator (1) will light up.

2. Press button (2) for testing, voltage will be cut off, indicator (1) will light 

down and restart button (3) will go upwards.

3. Press button (3) to restart the appliance, voltage will be restored and 

indicator (1) will light up.

Electric socket should be no lower, than 10A, power card with copper inner 

part, cross-section of copper should be not less, than 3x1,5 mm

2

Electric plug has combined with GFCI.

NOTE:

- if pressing test button (2) voltage is not cut off and/or 

indicator (1) continues to be lighted, it means that GFCI 

safety device is not operating properly.
- if pressing restart button (3) voltage is not restored 

and/or indicator (1) doesn’t light up, it means that the 

water heater is not operating properly. In both cases 

disconnect the water heater and call the service center.
- to reduce the risk of an electric shock, do not 

disassemble, remove or fill liquid in this appliance.

Fig. 9

IMPORTANT! 

If water in the installation location contains a large 

amount of calcium, manganese or iron salts, then 

IT IS NECESSARY to mount a respective filter in 

the delivery system to reduce the amount of scale 

generated in the tank and on the heating element.

Fig. 10

1.2 Plug the power cord into the outlet, GFCI light must be on and blue light 

at control panel must be on. 

2. Water heating mode setting

To set required mode, please, rotate heating mode setting knob to one of 

position mentioned below:
- «       » - save mode (800 W). In this mode when heating element is on – left 

red control panel light is on 
- «    » - medium heating mode (1200W).  In this mode when heating 

element is on – right red control panel light is on
- «     » - maximum capacity heating mode (2000 W).  In this mode when 

heating element is on – both right and left red control panel lights are on. 

3. Water heating temperature setting. 

3.1. Temperature can be set within the range 35°С-75°С, in increments 

of 1°С. 
3.2.To increase water temperature please rotate handle clockwise
3.3. To decrease water temperature please rotate handle counterclockwise
3.4. The water heater automatically maintains water temperature. When 

water temperature in the water heater reaches the set temperature, the 

heating element is automatically switched off.  When water temperature 

in the water heater drops to a certain level, the heating is automatically 

switched on. 

NOTE:

During normal operation the cold water supply valve 

must be set “open”.

2

1

Summary of Contents for SWH FSM3 100 V

Page 1: ... H SWH FSM6 80 H SWH FSM6 100 H SWH FSM3 30 V SWH FSM3 50 V SWH FSM3 80 V SWH FSM3 100 V SWH FSM4 30 H SWH FSM4 50 H SWH FSM4 80 H SWH FSM4 100 H Electrical storage water heater Outlook of devices aslo colour scores can be revised without any special advance notices Производитель вправе менять внешний вид прибора и цветовую гамму при бора без специального уведомления FSM5 FSM6 FSM3 FSM4 ...

Page 2: ...ons may harm health of the user and other people as well as damage their property 1 Any electrical appliance must be supervised when in operation espe cially if there are children nearby Make sure children do not touch the ap pliance 2 Prior to installing the water heater not connecting it to electrical main check and make sure the outlet for the water heater has a ground pin and if it is properly...

Page 3: ...7 8 7 8 7 8 7 Rated power W 2000 2000 2000 2000 Stage power W 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Tank capacity L 30 50 80 100 Rated pressure Mpa 0 7 0 7 0 7 0 7 Water protection class IPX4 IPX4 IPX4 IPX4 Heating time at Δ 30 ºC min 28 46 73 80 Appliance dimensions mm 550x435x238 855x435x238 991x493x270 1190x493x270 Weight kg 9 8 13 4 18 9 23 4 Factual year energy consumption k...

Page 4: ... 5 heating element 6 right composite protective cover 7 temperature sensor case 8 composite pressure safety valve be sure to install onto the cold water supply tube Pos A 9 emergency discharge of surplus water pressure a small water leakage is possible from the emergency discharge hole when the water heater is operating It is normal 10 inlet nozzle with a splitter 11 hot water outlet nozzle 12 eme...

Page 5: ...umber of consumption points to the outlet nozzle marked red 7 Check leak integrity of joints open the shut off cock and one of the cock assemblies After the tank is filled with water as evidenced by issue of water from the cock assembly shut the cock assembly and check the leak integrity of all joints Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa press...

Page 6: ... connected to the outlet Do it in the following order insert the power plug into the outlet switch off the water heater after half hour operation and unplug the cord check if the plug is heated by your hand If the plug is heated over 50 C then to prevent damages accidents and fire as a result of bad electrical contact replace the outlet with a new one A specialist must do this 3 Power cord of the ...

Page 7: ... used to activate timer and night heating 8 button It is used to increase the selected value 9 MODE button It is used to set time and timer 1 Time indication 2 Timer activation indicator It lights up when water heater on off timer is activated 3 Energy save indicators They light up when selecting low heating power 800 W 4 Water heater water temperature indicator 5 Mode button It is used to set tim...

Page 8: ...night heating at that indicator on the display will light up 6 2 Press timer button twice again to deactivate night heating at that indicator on the display will light down 7 Timer and night heating Timer and night heating can be activated simultaneously For this purpose it is necessary to press timer button several times until timer and night heating indicators light up simultaneously 8 Control p...

Page 9: ...h Water temperature control system is damaged Contact a repairer TIMBERK service center Water leakage Seal at the point of pipe connection is broken Replace the joint seal Water flows from the appliance s case Breaking of the internal tank corrosion Seal at the point of the heating element connection is broken Contact a repairer TIMBERK service center Failure Cause Troubleshooting method E1 Dry he...

Page 10: ...нтура в вашей электросети эксплуатация водонагревателя опас на для жизни 3 Подключайте водонагреватель только к сети 230В 50Гц При не обходимости выясните характеристики своей сети у поставщиков электроэнергии 4 Во избежание перегрева и риска возникновения пожара а также повреждения внутренней электрической сети не изменяйте длину сетевого шнура и не подключайте водонагреватель через электри чески...

Page 11: ...0 230 50 Номинальная сила тока A 8 7 8 7 8 7 8 7 Номинальная потребляемая мощность Вт 2000 2000 2000 2000 Мощность по ступеням Вт 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Объем л 30 50 80 100 Номинальное давление МПа 0 7 0 7 0 7 0 7 Класс влаго защиты IPX4 IPX4 IPX4 IPX4 Класс защиты I I I I Время нарева при Δ 30 ºC мин 28 46 73 80 Размеры прибора мм 550x435x238 855x435x238 991x493x...

Page 12: ...лектрический водонагреватель следует устанавливать на прочной стене 2 Стена на которой устанавливается электрический водонагрева тель должна выдерживать как минимум двойной вес водонагрева теля полностью заполненного водой на стене должны отсутствовать трещины и другие повреждения В противном случае необходимо при нять меры для усиления крепления или установить водонагреватель на специальной опоре...

Page 13: ...керные болты следует преду смотреть свободное пространство между нижней частью водонагревателя и полом не менее 0 6 м а для серии FSM6 FSM4 ещё и свободное про странство между боковой крышкой с правой стороны и стеной для обеспечения удобства тех нического обслуживания при необходимости его проведения Монтаж водонагревателя 1 Электрический водонагреватель следует устанавливать на проч ной стене Ес...

Page 14: ...роверку проводите в следующем порядке вставьте электрическую вилку в розетку через полчаса работы выключите водонагреватель и вынь ВНИМАНИЕ Перед подключением накопительного водона гревателя убедитесь в том что водонагреватель заземлен надлежащим образом Правильное за земление важно для минимизации ударов током и опасности возгорания Шнур питания оснащён вилкой с контактом заземления Устройство до...

Page 15: ...ньшаете температуру нагрева воды 3 4 Водонагреватель автоматически поддерживает температуры воды Когда температура воды внутри водонагревателя достигает установленной пользователем температуры нагрев автоматически выключается при этом на панели управления светится только инди катор питания голубого цвета Когда температура воды внутри водонагревателя понижается ниже установленного уровня нагрев авт...

Page 16: ...лятора против часовой стрелки от по зиции max к позиции min или нажмите кнопку чтобы умень 3 Выбор режима мощности 3 1 Нажмите на ручку терморегулятора на панели управления несколь ко раз или на соответствующие кнопки на ПДУ чтобы выбрать необхо димую мощность нагрева 3 2 При выборе низкой мощности нагрева на панели управления за гораются индикаторы energy save а на дисплее отображается инди катор...

Page 17: ...тся рядом с ТЭНом имеет круглую форму рис 14 для вертикальных водонагревателей серии FSM5 FSM3 нажать до щелчка кнопку расположенную по центру термовыключателя рис 15 если кнопка не нажимается и нет щелчка то подождать пока термо 6 Чтобы правильно слить воду из внутреннего бака надо восполь зоваться сливным отверстием только для серии FSM6 FSM4 надо открутить заглушку закрывающую сливное отверстие...

Page 18: ...ие электросхемы изделия которое может быть выполнено без уведомления потребителя По окончании срока службы водонагреватель следует утилизировать Подробную информацию по утилизации водонагревателя Вы можете получить у представителя местного органа власти Срок службы во донагревателя составляет 15 лет 13 УТИЛИЗАЦИЯ Серийный номер изделия месяц и год изготовления указаны в со ставе ID LINE кода издел...

Page 19: ...ей техники Timberk мы дополнительно сообщаем что русский является государствен ным языком в следующих госу дарствах в Российской Федерации в Республике Беларусь наряду с белорусским языком в частично признанной Южной Осетии наряду с осетинским языком Русский язык является офици альным языком во всех случаях другой язык или другие языки выступают как государствен ный или второй официальный в следую...

Page 20: ...рический накопительный водонагреватель 39 38 Если вы заметили ошибку в руководстве пожалуйста сообщите нам об этом связавшись с нами по электронной почте указанной на сайте www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com ...

Page 21: ...www timberk com ...

Reviews: