9. MAINTENCE

Fig. 11

Fig. 12

Fig. 13

1. Check the power plug and outlet as often as possible. Secure electrical 
contact and also proper grounding must be provided. The plug and outlet 
must not heat excessively.

2. If the water heater is not used for a long time, especially in regions with 
low air temperature (below 0°C), it is necessary to drain water from the 
heater .

3. To ensure long reliable water heater operation, it is recommended to 
regularly clean the internal tank and remove deposits on the electric heating 
element of the water heater, as well as check condition of the magnesium 
anode and, if necessary, replace it with a new one.

4. Preventive operations must be performed upon strict observance of the 
operation manual and safety precautions.

5. The water heater is equipped with a thermal switch, which cuts off power 
supply of the heating element upon water overheating or its absence in the 
water heater. If the water heater is connected to the mains, but water is 
not heated and the indicator doesn’t light up, then the thermal switch was 
switched off or not switched on. To reset the water heater to the operating 
condition, it is necessary to:

- de-energize the water heater, remove the plate of the side / lower cover 
for horizontal-type/vertical-type water heater respectively. 

- for FSL2/FSP2 series horizontal-type water heaters: press the button, 
located in the center of the thermal switch, placed near the heating element 
(with a round shape), until it clicks, Fig.12;

- for FSL1/FSP1 series vertical-type water heaters: unscrew retaining nut of 
the thermal switch, fastened on the flange of the heating element, turn the 
thermal switch and press the button, located in the center of the thermal 
switch, until it clicks; Fig. 13;

- if the button is not pressed and there is no clicking, then you should wait 
until the thermal switch cools down to the initial temperature.

6. To drain water from the internal tank properly, you need to use the drain 
hole (only for FSL2/FSP2 line) (it is necessary to unscrew a plug, covering 
the drain hole), water can also be drained through a composite relief valve 
(Fig. 11) (unscrew the composite relief valve drain knob screw and set the 
drain knob to the upper position, at that hot water tap must be open, and 
cold water supply valve must be closed).

7. Bear in mind to check serviceability of the relief valve every 14 days – 
inspection method:

- turn the discharge lever to the left up until you feel the change of thread, 
then water must start flowing from the valve’s hole. After checking the 
water flow, return the lever to its initial position.

8. If necessary, wipe external surfaces of the heater by a damp cloth with 
soap.

IMPORTANT! 

The manufacturer provides an extended guarantee 

for particular water heater components provided that 

timely and proper routine maintenance is performed 

by specialists of an authorized service center (see the 

guarantee card).

IMPORTANT! 

If these actions had no positive result or the thermal 

switch turns off repeatedly during a short period of 

time, then you should de-energize the water heater, 

cut off water supply and contact your local Timberk 

Authorized Service Center for a consult or repair of the 

appliance.

Possible malfunctions and troubleshooting methods

Table 4

10. TROUBLESHOOTING

Failure

Possible causes

Troubleshooting method

Heating indicator light doesn’t light up, 
water is not heated

1. Temperature adjustment device 
is broken.

Contact a repairer, TIMBERK service 
center.

2. Temperature limiter was actuated or 
was not switched on.

Switch on the temperature switch 
following instructions on its activation. 
(page 12)

3. Temperature limiter is broken.

Contact a repairer, TIMBERK service 
center.

Water doesn’t flow from the hot water 
discharge cock

1. Water feed is cut off.

1. Wait until water supply is restored.

2. Water pressure is too low.

2. Switch on the water heater again, 
when normal water pressure restores.

3. Water supply exhaust valve is 
closed.

Water temperature is too high

Water temperature control system 
is damaged.

Contact a repairer, TIMBERK service 
center.

Water leakage

Seal at the point of pipe connection 
is broken.

Replace the joint seal.

Water flows from the appliance’s case

Breaking of the internal tank 
(corrosion)Seal at the point of the 
heating element connection is broken.

Contact a repairer, TIMBERK service 
center.

11. TRANSPORTATION AND STORAGE 

CONDITIONS

Temperature 
requirements*

Humidity 
requirements*

Transportation and 
storage

From -30° to +50°

From 15% to 85% 

(without a condensate)

We are exploring new technologies and we constantly improving the quality 
of our products. That’s why specifications, design and accessories are 
subject to change without any specific notice.

3. Temperature display (only for FSP series)

All FSP series models are equipped with temperature display shows 
current water temperature in whater haeter tants. 

IMPORTANT! 

Water may start dripping from the relief valve hole 

during heating. It is impossible to avoid water leakage 

and you must not prevent it since valve blocking 

may cause rupture of the internal tank (in case of 

equipment failure).

Summary of Contents for SWH FSL1 100 V

Page 1: ...FSL2 100 H SWH FSP1 30 V SWH FSP1 50 V SWH FSP1 80 V SWH FSP1 100 V SWH FSP2 30 H SWH FSP2 50 H SWH FSP2 80 H SWH FSP2 100 H FSL1 серия series FSP1 серия series FSL2 серия series Electrical storage water heater Outlook of devices aslo colour scores can be revised without any special advance notices Производитель вправе менять внешний вид прибора и цветовую гамму при бора без специального уведомлен...

Page 2: ... health of the user and other people as well as damage their property 1 Any electrical appliance must be supervised when in operation espe cially if there are children nearby Make sure children do not touch the ap pliance 2 Prior to installing the water heater not connecting it to electrical main check and make sure the outlet for the water heater has a ground pin and if it is properly earthed If ...

Page 3: ...8 1 23 1 33 1 45 Description Units SWH FSP1 30 V SWH FSP2 30 H SWH FSP1 50 V SWH FSP2 50 H SWH FSP1 80 V SWH FSP2 80 H SWH FSP1 100 V SWH FSP2 100 H Rated voltage V Hz 230 50 230 50 230 50 230 50 Rated current A 8 7 8 7 8 7 8 7 Rated power W 2000 2000 2000 2000 Stage power W 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Tank capacity L 30 50 80 100 Rated pressure Mpa 0 7 0 7 0 7 0 7 Prot...

Page 4: ... tube 5 heating element 6 right composite protective cover 7 temperature sensor case 8 composite pressure safety valve be sure to install onto the cold water supply tube Pos A 9 emergency discharge of surplus water pressure a small water leakage is possible from the emergency discharge hole when the water heater is operating It is normal 10 inlet nozzle with a splitter 11 hot water outlet nozzle 1...

Page 5: ...to the outlet nozzle marked red 7 Check leak integrity of joints open the shut off cock and one of the cock assemblies After the tank is filled with water as evidenced by issue of water from the cock assembly shut the cock assembly and check the leak integrity of all joints Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa pressure maximum pressure is 0 7 ...

Page 6: ...must be designed for rated current not less than 10A The power outlet and plug must always be dry to prevent current leakage Regularly check if the power plug is tightly connected to the outlet Do it in the following order insert the power plug into the outlet switch off the water heater after half hour operation and unplug the cord check if the plug is heated by your hand If the plug is heated ov...

Page 7: ...discharge lever to the left up until you feel the change of thread then water must start flowing from the valve s hole After checking the water flow return the lever to its initial position 8 If necessary wipe external surfaces of the heater by a damp cloth with soap IMPORTANT The manufacturer provides an extended guarantee for particular water heater components provided that timely and proper rou...

Page 8: ... данном руководстве по эксплуатации содержится важная инфор мация касающаяся Вашей безопасности а также рекомендации по правильному использованию прибора и уходу за ним Сохраните ру ководство по эксплуатации вместе с гарантийным талоном кассовым чеком по возможности картонной коробкой и упаковочным матери алом В данном руководстве по эксплуатации описываются разные виды данного типа устройства При...

Page 9: ...екающей воды 15 Не используйте водонагреватель в целях не предусмотренных этим руководством по эксплуатации 16 Не используйте водонагреватель во взрывоопасной или коррози онной среде Не храните рядом с прибором бензин и другие летучие легковоспламеняющиеся жидкости это очень опасно 17 Запрещено вносить изменения в конструкцию водонагревателя или модифицировать его 18 Любые сервисные работы должны ...

Page 10: ...66 500 238 435 450 20 73 80 991 298 450 270 493 510 20 91 5 100 1190 298 550 270 493 510 20 91 5 5 ОПИСАНИЕ ВОДОНАГРЕВАТЕЛЯ 1 Левая комбинированная защитная крышка 2 Внутренний резервуар 3 Система переливов 4 Верхняя часть патрубка забора горячей воды 5 Нагревательный элемент 6 Правая комбинированная защитная крышка 7 Трубка датчика термостата и датчика температуры 8 Комбинированный предохранитель...

Page 11: ... избыточного давления воды при работе водона гревателя возможно слабое подтекание воды из отверстия аварийного слива Это нормально 14 Патрубок выхода горячей воды 15 Верхняя часть патрубка забора горячей воды 16 Панель управления В зависимости от партии товара УЗО может быть расположено не в составе сетевого шнура Датчик температуры доступен только для водонагревателя серии FSP1 ВНИМАНИЕ Водонагре...

Page 12: ...ащения протечки при подсоединении труб используйте резиновые уплотнительные прокладки на резьбовых окончаниях труб 4 На входной патрубок обозначенный голубым цветом и стрелкой направления течения воды накрутите предохранительный клапан так чтобы течение воды совпадало с направлением стрелки на корпусе клапана На отверстие сброса давления предохранительного клапана см рис 11 оденьте дренажную трубк...

Page 13: ...ься индикаторная лампочка в УЗО и индикатор питания голубого цвета на панели управления Эксплуатация водонагревателя 1 Включение 1 1 Сначала откройте один из кранов выхода горячей воды затем от кройте кран подачи холодной воды Электрический водонагреватель начнёт заполняться водой Когда из крана горячей воды свободно вытекает вода это означает что водонагреватель полностью запол нился водой и кран...

Page 14: ...центру термовыключателя кото рый находится рядом с ТЭНом имеет круглую форму рис 12 для вертикальных водонагревателей серии FSL1 FSP1 нажать до щелчка кнопку расположенную по центру термовыключателя рис 13 если кнопка не нажимается и нет щелчка то подождать пока термо выключатель остынет до и исходной температуры 6 Чтобы правильно слить воду из внутреннего бака надо восполь зоваться сливным отверс...

Page 15: ... программы клиентской поддержки Теперь вы всегда сможете заказать и оформить доставку на запасные части и расходные материалы необходимые для оптимальной качественной работы техники Timberk в течение всего срока службы на едином портале www btpart ru Всю информацию о работе портала вы также всегда сможете увидеть на сайте www timberk com Мы искренне надеемся что этот уникальный дополнительный серв...

Page 16: ...венный или второй официальный в сле дующих государствах и на терри ториях в Республике Казахстан в Киргизской Республике в административных единицах Украины где доля носителей русского языка cоставляет более 10 при соответствующем решении местных советов в Автономной Республике Крым В Республике Таджикистан рус ский язык признан по Конституции языком межнационального обще ния Официальным языком ме...

Page 17: ...www timberk com ...

Reviews: