38
7. THERMAL SAFETY ALARM (THERMOSTAT)
The reason:
The function of the safety thermostat is to prevent the pellets from burning
inside the pellet storage due to the increased temperature in the pellet conveyor tube. An
alarm will sound if the safety thermostat shows a temperature higher than that required to
start the stove. The thermostat responds by switching off the pellet conveyor and the control
unit activates alarm mode (LED alarm lights). The screen shows the text "THERMAL
SAFETY". Stove will shut down.
What to do?
Cancel the alarm: Unscrew
the safety thermostat cover (1) and check
that the needle (2) is pulled in or out. If
the needle is pulled out, press the needle
and put the stove back into operation. If
the needle is retracted or unable to
retract and the stove still reports the
same error, call a service technician
.
8. ALARM MALFUNCTION OF EXHAUST FAN
Reason:
An alarm occurs if the exhaust fan malfunctions. The display shows "EXHAUST
FAILURE".
An error may occur due to:
- fan blocking,
- malfunctions of the contact supplying the fan with electricity,
- disconnects cables that measure fan speed.
If this error occurs, be sure to contact service technician.
The alarm can also be triggered by an increase inside the exhaust fan temperature.
What to do?
In this case it is necessary to clean the stove (monthly cleaning), as well as
the blades of the fan.
9. ALARM MALFUNCTION OF AMBIENTE TEMPERATURE
PROBE
If the ambient temperature probe is malfunctioning, the scree will indicate 00.0
o
C. If the
real room temperature is 0
o
C, the same will be displayed. Hold the tip of the probe to be
heated by holding it between your fingers. Check the screen if temperature is increasing.
If this does not happen then the probe is defective. If the probe malfunctions, call a service