37
Malfunction of lighter can be observed when there are no sparks or hot pellets when starting
the stove. Over time, the power of the lighter decreases and its deformation is possible. A
deformed lighter touches the tube in which it is located and transfers some of its heat to it.
Because of this, the lighter does not transfer enough temperature to the pellet and does not
ignite. In case of urgent need, add pellet in to burning pot and start fire manually with fire
starter (cube or a gel), for ignition, but it is necessary to contact an authorized service as
soon as possible and install a new lighter.
4. ALARM OFF PELLET DEFICIENCY
The reason:
Due to the lack of pellets and less combustion, the exhaust gas temperature
drops below the values determined by the parameters.
"ALARM NO FIRE
" will appear on
the screen and the stove will enter alarm mode.
What to do
? Cancel the alarm and wait for the stove to cool. Then, proceed as described in
Section 8.6 Menu 06 - START PELLET INSTALLATION and start the stove.
NOTE: This alarm can also occur due to a pellet jam in the pellet conveyor.
5. ALARM POWER OUTAGE
Reason:
There may be a power outage while the stove is operating. If the power failure is
shorter than the time specified by the technical parameter, when the oven is switched on
again, it will continue to operate in operating mode. Otherwise, the alarm will sound. The
message "BLACK OUT" will appear on the screen and the oven will switch off on its own.
6. ALARM OF INSUFICIENT UNDERPRESSURE IN THE FIREBOX
Reason:
The alarm is triggered when the underpressure in the firebox is below the level
required for ignition and combustion of the pellets. The presser will react by suspending the
operation of the pellet conveyor.
The display shows "ALARM DEP FAIL" and the oven switches off.
A fault in the safety gap can occur if:
-the oven dirty,
-the oven doesn't breathe well
-if the chimney or smoke ducts in the furnace are clogged,
- if the fan speed is insufficient,
- due to strong wind.
What to do?
Clean the stove and flue pipes. Check that the door of the firebox and the
ashtray are well closed. Check that the braids located on the door and the ashtray are in
good condition. If the braids are well placed, check the chimney pressure.
The chimney is checked by bringing the flames to the smoke outlet on the wall (rosette). If
the flame turns toward the smoke outlet then a underpressure is appropriate. If the flame
returns to the room or if it is stationary then the chimney overpressure is bad. In that case,
call the chimney sweep. Cleaning the stove is described in the section
“CLEANING AND
MAINTENANCE
”.