Tim Sistem NIKA Owner'S Manual Download Page 14

Glass  on  a  firebox  door 
are  getting  sooty  for  a 
while 

Wet wood 
Too much fuel 
Insufficient draft 
Closed intake of secundary air 

Use a dry wood 
Check a suggested quantity of a 
fuel provided in a user’s manual 
Check  a  connection  with  a 
chimney  
Read  carefully  the  instructions 
and apply advices how to provide 
secundary air 

 

GENERAL RECOMMANDATION 

If  you  have  fullfield  all  the  recommendations  for  installation,  operation  and  control  of 
cleaning, giveen in this manual, the stove is now tested, safe device for household use. 

Before installing the stove, remove the package. Be aware of potential injuries because the 
wooden  slats  are  connected  with  nails.  Dispose  a  plastic  bag  in  accordance  with  the 
regulations.  Old  stove  you  do  not  want  to  use  anymore,  dispose  to  designated  areas  in 
accordance with the regulations. 

All  complaints,  perceived failure  or malfunctioning  stoves,  should  be reported  to the factory 
or  authorized  service  center  by  telephone  or  in  written,  only  with  fiscal  receipt.  All  contact 
information provided at the end of this guide. 

Any malfunction of the stove, must be removed by the 

manufacturer’s service only. 

If  unauthorized  persons  carry  out  any  servicing  or  repairs  and  alterations  to  the  stove,  the 
owner loses the right to the manufacturer's warranty. 

Supply of spare parts has to be done via 

manufacturer’s service, based on the position and 

image of this manual. 

The  manufacturer  does  not  assume  any  responsibility  if  the  buyer  fails  to  comply  with  the 
instructions for use and installation of the stove. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for NIKA

Page 1: ...NIKA Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 13240...

Page 2: ...Keep it handy and refer to it as needed You will find in it information that will be useful now and in the years to come Make sure that when installing the stowe all security standards have been respe...

Page 3: ...Do not allow children to handle and play near the stove Only spare partes reccomended and allowed by the manufacturer should be installed on the stove You must not make any changes on the stove With...

Page 4: ...box doors are made of cast iron with fireproof glass Connection for smoke drain is being put on the plate and connected with screws All the materials that Nika stove is made can be recycled Sealing el...

Page 5: ...fire place WxLxH mm 360x390x370 Weight kg 113 Minimum distance from flammable materials Back mm 500 Side mm 500 Front mm 1000 Content CO reduced on 13 O2 0 00713 Chimney connection mm 120 Chimney con...

Page 6: ...DIMENSIONS OF THE STOVE...

Page 7: ...cross section of pipe smoke The stove requires insertion of fresh air in the room where it is installed with surface openings for insertion of fresh air should not be less than 0 4 dm The unit for fre...

Page 8: ...2 Excessive slope 3 A sudden change of direction of the flue channel 4 Stove or some other device connected to the same flue channel 5 Bulges in the flue channel 6 Cracks 7 Alien body or accumulated g...

Page 9: ...ttes are lit and then reduce the draft in half when adding fuel Fig 1 pos 1 open the fire door step by step wait for 4 5 seconds and then slowly open it wide Do not open the door suddenly when there s...

Page 10: ...eaning of the stove and chimney Regular room ventilation for better combustion Regular ash tray cleaning Accumulated slag and unburned material regularly remove from the grid HANDLING THE STOVE OPERAT...

Page 11: ...e extinguisher Before the second charging clean the grid in order to provide the fresh air Regularly clean the ash pan making sure that there is always a place for ashes The furnace is designed to ope...

Page 12: ...wood or briquettes After that depending on what position is the regulator will depend the intensity of the combustion If the secondary air regulator remains in the open position intensity of burning...

Page 13: ...ol is recommended at least once a year and after a long downtime Regular maintenance and control of the chimney will prevent the occurrence of fire and poor operation of the stow MALFUNCION RECMMENDAT...

Page 14: ...astic bag in accordance with the regulations Old stove you do not want to use anymore dispose to designated areas in accordance with the regulations All complaints perceived failure or malfunctioning...

Page 15: ...ntial source of danger Take care of safe removing and disposing of wooden boards because they are connected with nails PRODUCT The device is made of materials that can be recycled When disposing the w...

Page 16: ...SOLID FUEL STOVE NIKA...

Page 17: ...mbly 12 Back panel bracket 13 Front panel bracket 14 Grate 15 Grate curier 16 Firebox lateral refractory 17 Firebox rear refractory 18 Firebox upper refractory 19 Smoke drain 20 Front grid 21 Secondar...

Page 18: ...ovide spare parts in due time after the stove is no longer produced This warranty does not cover damage caused by inadequate use of stoves violating the instructions given in this manual mechanical da...

Page 19: ...______________________________________ __________________________________________________________________________ __________________________________________________________________________ ___________...

Page 20: ...TIM SISTEM d o o Prva industrijska 9 22 330 Nova Pazova tel fax 381 22 328 076 e mail office timsistem rs www timsistem rs...

Reviews: