![Tim Sistem NIKA Owner'S Manual Download Page 13](http://html1.mh-extra.com/html/tim-sistem/nika/nika_owners-manual_1116377013.webp)
CLEANING AND MAINTENANCE
Regular and proper cleaning allows proper operation and long life of the stove. All cleaning
the interior or exterior surfaces are always performed in a cold oven.
Cleaning exterior surfaces
- is done with a soft cloth that will not damage the surface of the
stove. Cleaners of chemical origin can damage the surface of the fire place and cannot be
used. Painted surfaces must not be cleaned with abrasive products.
Cleaning inter surfaces
– when cleaning use protective gloves.
Clean the bottom of the oven from accumulated ash and pick up small unburned pieces of
the grid, clean the ashtray and ash accumulated in the interior of the fireplace.
Cleaning glass surfaces
- glass on the firebox may get dirthy during the operation.. For
cleaning use a mild detergent. Do not use abrasive cleaners because they can damage the
surface of the glass. Clean the glass only when cool.
Cleaning and maintenance of the chimney
- chimney cleaning and control is
recommended at least once a year and after a long downtime. Regular maintenance and
control of the chimney will prevent the occurrence of fire and poor operation of the stow.
MALFUNCION. RECMMENDATIONS FOR ITS ELIMINATONS
The following table shows the most common defects and recommendations for their removal.
Table: Showing the most common malfunctions, possible causes and ways of eliminating it.
Malfunction
Possible cause
Howe to remove it
Oven heats poorly
improper handling,
Poor uptake
Read carefully and follow the
instructions.
In the case that despite all
instructionshave been respected,
malfunctions are still not
removed, call the customer
service.
Difficulties in lighting fire
Closed regulator of air supply,
Wet wood,
Lack of oxygene
Open the regulator of air
supplyand provide a supply of a
primary air
Use a dry wood
Ventilate a room in order to
provide a supply of fresh air
Smoke reenters into a
room
Closed regulator of air supply,
Insufficient draft,
Remainings of ashes on a grid
Open the regulator of air
supplyand provide a supply of a
primary air
Read carefully the instructions
and apply advices how to provide
a draft
Clean the grid