15
EN
choose to disconnect the power, the water heater should be thoroughly drained
before the onset of freezing conditions. Water from the heater is drained through the
inlet/outlet pipe of the heater.
The exterior of the water heater may be cleaned with a mild detergent solution. Do
not use solvents and abrasive cleaners.
With regular service inspections you will ensure faultless functioning and long life of
the heater. Tank corrosion warranty applies only if all the prescribed regular
inspections of the protective anode wear have been made. The period between
regular inspections should not be longer than stated in the warranty certificate.
Inspections should be carried out by authorised service providers that will record
each inspection on the warranty statement of the product. Upon inspection the
service provider will inspect the amount of wear on the anti
-
corrosion anode and, if
necessary, clean the limescale that accumulates depending on the quality, quantity
and temperature of the water inside the heater. The service provider will also
recommend the date for the next inspection depending on the condition of the heater.
In the event of the heater breaking down, you are kindly requested to contact
the authorised maintenance service provider located closest to you. Please do
not attempt to carry out any repairs yourself.
TECHNICAL PROPERTIES OF THE
APPLIANCE
1)
EU Regulation 812/2013; EN 50440
2) EN 50440
WE RESERVE THE RIGHT TO MAKE CHANGES THAT DO NOT IMPAIR THE
FUNCTIONALITY OF THE DEVICE.
The user manual can also be found at our website http://www.tiki.si.
Type
GT 5 O
GT 5 U
GT 10 O
GT 10 U
GT 15 O
GT 15 U
Declared load profile
XXS
XXS
XXS
XXS
XXS
XXS
Energy efficiency class
1)
A
A
A
A
A
A
Water heating energy efficiency
(ƞwh)
1)
35,9
35,2
36,3
35,2
36,1
35,3
[%]
Annual electricity consumption
1)
514
525
508
524
510
523
[kWh]
Daily electricity consumption
2)
2,410
2,480
2,377
2,461
2,391
2,465
[kWh]
Thermostat temperature settings
ECO
Value of "smart"
0
0
0
0
0
0
Volume
6,2
6,6
9,8
9,9
14,8
14,9
[l]
Rated pressure
0,6 (6) / 0,9 (9) / 1,0 (10)
[[MPa
(bar)]
Weight / Filled with water
6,8 / 11,8
8 / 18
11 / 26
[kg]
Anticorrosion protection of the tank
Enamelled / Mg anode
Power of electrical heater
2000
[W]
Voltage
230
[V~]
Protection class
I
Degree of protection
IP24
Heating time from 10
°C
to
65
°C
11
20
29
[min]
Packaging dimensions
300x300x440
300x400x530
350x400x530
[mm]