Use and Maintenance Manual - X Series
Page
56
Hydraulic filter replacement
All models are equipped with suction filter inside the tank. It is advisable to replace it at least every two years.
To replace the suction filter inside the tank (figure
7-7):
stop the machine by pressing the emergency stop button on the ground control panel
disconnect the tubes from the tank
unscrew flange
A
unlocking the screws with a Phillips screwdriver
unscrew filter
B
from the suction tube and clean it with a detergent and a compressed air jet by blowing from the connection
or replace the filtering element
to restore the initial condition, carry out the above-mentioned operation in reverse order.
7-7:
Replace the filter using only original accessories available at our Technical Support.
Do not re-use used oil and do not leave it in the environment, but dispose of in compliance with local
standards in force.
Once the filter has been replaced (or cleaned), check the hydraulic oil level in the tank.