Multi-function AV Distribution System
24
5.4 TCP/IP Control
The system can be controlled over a network connection. A TCP/IP communication
software (e.g. TCP&UDP) needs to be installed on the control PC. After installing the
control software, create a connection according the below parameters:
Default IP-Address: 192.168.0.178
Default Subnet Mask: 255.255.255.0
Default Gateway: 192.168.0.1
TCP Port Number: 4001
Note:
All commands do need to end with “<CR><LF>”.
In the commands, “[”and “]” are symbols for easy reading and do not need to be
typed in actual operation.
Please remember to end the commands with the ending symbols “.” or “;”.
Please type the command carefully due to case sensitive.
Command
Description
Command and Feedback
Example
1A1.
Switch to input 1.
1A1.
1A2.
Switch to input 2.
1A2.
OHP Control OFF.
Display OFF.
OHP IR Control:OFF.
OHP Control ON.
Display ON.
OHP IR Control:ON.
PWOFF.
System OFF.
PWOFF.
PWON.
System ON.
PWON.
Mic Volume:[xx].
Set MIC volume to [xx]. [xx]=0~60
Mic Volume:30
Mic Volume:30
Source Volume:[xx].
Set source volume to [xx].
[xx]=0~60
Source Volume:30
Source Volume:30
Mute Mic.
Mute microphone.
Mute Mic.
Unmute Mic.
Unmute microphone.
Unmute Mic.
Mute Source.
Mute source audio.
Mute Source.
Unmute Source.
Unmute source audio.
Unmute Source.
Status.
Get all status.
SCALE FHD.
MODEL NAME:K12_TX1H.
…