31
HEATING & AIR CONDITIONING
The following is a brief overview of how best
to use the thermostat (Figure 3-8). For more
detailed instructions, please consult the ther-
mostat literature in the Owner’s Information
Package.
1. Use the “Thermostat” switch to select the de-
sired function (e.g., COOL, OFF, GAS HEAT,
or ELEC HEAT).
Note: In the “COOL” mode there will be a
delay of several minutes before the refriger-
ant in the air-conditioning system begins to
cool the motorhome, as the compressor is on
a time-delay circuit and it must also cool the
ductwork to the vents first.
2. Select the Fan Mode operation (AUTO or ON) and the Fan Speed operation (LO or HI) to select fan
speed desired.
3. Press the Up and/or the Down buttons to set the desired temperature for the motorhome.
NOTE: When the fan mode is in AUTO, the fan will cut on and off when the temperature reaches the
desired setting.
When the fan mode is on FAN, it will continue to run even though the compressor cycles on and off
when it reaches the desired temperature.
If the motorhome temporarily loses its 110 power, the air conditioning system will resume operation at
its last programmed setting once power is restored.
If 12v power is lost to the thermostat, it will automatically re-set to 72 degrees once power is restored.
NOTE: There is a thermostat control for each air conditioning unit, one located in the bedroom and
one in the living area.
To activate the heat pump, set the thermostat to ELEC HEAT and select desired temperature.
NOTE: If the setting on the thermostat and the room temperature are more than five degrees apart, the
Aqua-Hot heating system will automatically turn ON with the heat pump. Once the room temperature
reaches the desired level specified on the thermostat setting, the furnace will cut off and the heat pump
will maintain the heating of the coach.
NOTE: The heat pump is controlled by each individual thermostat.
If the external temperature falls to 35-38 degrees Fahrenheit, the heat pump will become inoperative
and the gas furnace will begin to operate automatically.
THERMOSTAT CONTROLS
HEAT PUMP CONTROLS
Figure 3-8: Thermostat
Summary of Contents for 2015 Phaeton
Page 8: ...1 GENERAL INFORMATION Chapter 1 To print a color copy visit www tiffinmotorhomes com ...
Page 17: ...10 SAFETY INSTRUCTIONS Chapter 2 To print a color copy visit www tiffinmotorhomes com ...
Page 32: ...25 HEATING AIR CONDITIONING Chapter 3 To print a color copy visit www tiffinmotorhomes com ...
Page 39: ...32 LP GAS SYSTEM Chapter 4 To print a color copy visit www tiffinmotorhomes com ...
Page 43: ...36 MAJOR APPLIANCES Chapter 5 To print a color copy visit www tiffinmotorhomes com ...
Page 51: ...44 ENTERTAINMENT Chapter 6 To print a color copy visit www tiffinmotorhomes com ...
Page 55: ...48 CABINETS FURNITURE Chapter 7 To print a color copy visit www tiffinmotorhomes com ...
Page 60: ...53 STRUCTURAL FEATURES Chapter 8 To print a color copy visit www tiffinmotorhomes com ...
Page 62: ...55 ELECTRICAL FEATURES Chapter 9 To print a color copy visit www tiffinmotorhomes com ...
Page 77: ...70 SLIDE OUT FEATURES Chapter 10 To print a color copy visit www tiffinmotorhomes com ...
Page 81: ...74 EXTERIOR FEATURES Chapter 11 To print a color copy visit www tiffinmotorhomes com ...
Page 87: ...80 INTERIOR FEATURES Chapter 12 To print a color copy visit www tiffinmotorhomes com ...
Page 91: ...84 PLUMBING BATH FEATURES Chapter 13 To print a color copy visit www tiffinmotorhomes com ...
Page 108: ...DRIVING YOUR MOTORHOME Chapter 15 101 To print a color copy visit www tiffinmotorhomes com ...
Page 113: ...ROUTINE MAINTENANCE Chapter 16 106 ...
Page 148: ...MAINTENANCE DATA CHARTS Chapter 17 141 To print a color copy visit www tiffinmotorhomes com ...