4.2 Notice for usage and maintenance: 

4.2.1 Power must be cut off when actuator’s any cover is open.(please see the warning plate: “Forbid to 

open the box cover when the power is on.”)   

4.2.2 Forbid to hit the openness window by using hard materials. 

4.2.3 Keep the nameplate and warning plate being fixed on actuator and the words on them should be 

recognized. 

4.2.4 Don’t open the electric box cover outdoors in rainy day or windy day. 

4.2.5 The product’s explosion-proof cover cannot be knocked or scratched during maintenance or 

debugging. 

4.2.6 Apply anti-rust painting 204-1 after debugging or maintenance and before assembling. 

4.2.7 Please notify the company to change the broken explosion-proof elements. The products cannot be 

powered on until it is renewed with qualified element. 

4.2.8 Fasten the screws on the control box cover and wiring box cover after product debugging . After some 

strong vibration, please make regular check to make sure whether it is reliable. Sealing structure cannot be 

damaged at the same time. Tightness      should be confirmed.   

4.2.9    O-ring shall be kept properly. If damaged, change for a new one as soon as possible. 

4.2.10 External grounding shall be safe and sound. 

4.2.11 Connect the actuator’s external ground, and it should be reliable and safe. 

4.3 Notice for the electric schematic diagram and electrical wiring   

Besides the Manual Operation, a copy of electric schematic diagram has been provided. User shall 

strictly follow the terminal diagram while wiring. Wiring lug shall be applied. The wiring lug shall not 

exposed or loosened. Uplift the plastic jacket of the wiring lug(same direction ) to make sure an appropriate 

leakage distance. Any electric conductor cannot be left in the wiring case.   

 

5. Comprehensive test and notice 

5.1 Comprehensive test 

5.1.1 When manually operate the valve for one travel, check if the pointer and stroke transmission work 

well and also check the performance of manual operation. 

5.1.2 Electrically operate the valve to the fully-closing position. The limit control mechanism shall be 

sensitive. The Close Indicator will light up and pointer will points to “0” at that time. 

5.1.3  Electrically operate the valve to the fully-open position. The limit control mechanism shall be 

sensitive and is able to open the valve. The Open Indicator will light up and pointer points to “100”at that 

time. 

5.2 Notice 

5.2.1 Fasten the screw on the control case after product adjustment. Sealing components shall be kept well 

so that outdoor performance of the product can be ensured. 

5.2.2 After maintenance, user shall check if limit control mechanism, position indicator and torque control 

mechanism comply with requirements. Readjustment shall be made if possible. 

5.2.3 The sealing plug would be damaged if it is used after several times of dismounting. In this case, user 

can purchase from manufacturer or produce according to required dimensions. 

 

Summary of Contents for QBR3

Page 1: ...d this Operation Manual carefully before using this product SM 20 QBR3 QBR5 Quarter turn Electric Valve Actuator Operation Manual Tianjin Baili Ertong Machinery Co Ltd Former Tianjin No 2 General Machinery Factory ...

Page 2: ...Content 1 Product instruction 1 2 Electric wiring 2 3 Product adjusting 3 4 Additional Instruction for Explosion proof product 4 5 Comprehensive test and notice 5 ...

Page 3: ...e medium 1 2 9 Electric port total number of M33 1 5 is 2 1 3Majorstructureandfunction 1 3 1 Motor YDF specialized electric valve motor This kind of motor complies with relatednationalstandardanditstorqueperformancecomplieswithvalve sloadingperformance 1 3 2Reducermechanism it applies first class spur gear first class worm gear and first class NN type planetary reducer 1 3 3Limitcontrolandposition...

Page 4: ...ensure that the cable will not influence other working parts in the control case 2 1 4 Put the sealing ring and gasket into the case s screw hole rotate gland nut and compress sealing ring so as to make it closely contact with cable s edge 2 1 5 Inner grounding and external grounding should be fixed and reliable 2 2 Wiring steps for explosion proof type of electric actuator see Fig 4 2 2 1 Remove ...

Page 5: ... rain leaking into the electric actuator the first two connection patterns are right in the following picture 3 Product adjusting The torque mechanism has been tested and set up before delivered from the factory It complies with the maximum torque value written on the nameplate User does not need to readjust see Fig 2 Besides fasten two mechanical limit screws on the main case body It is better no...

Page 6: ...s gear and make it to be meshed To confirm it is meshed before fasten the screw Take care of the limit position or it would be damaged 3 3Adjustment for the mechanical limit screws A To make sure in which valve position the screw limits before adjusting the mechanical limit screw While turning the valve right is to close the limit screw on the right side is closing limit and the limit screw on the...

Page 7: ... Besides the Manual Operation a copy of electric schematic diagram has been provided User shall strictly follow the terminal diagram while wiring Wiring lug shall be applied The wiring lug shall not exposed or loosened Uplift the plastic jacket of the wiring lug same direction to make sure an appropriate leakage distance Any electric conductor cannot be left in the wiring case 5 Comprehensive test...

Page 8: ...inal protection function in the above conditions 2 At the end of operation replace the cover When fastening the clamp nuts at wire inlet and outlet make sure that no adverse elements such as severe damp water and dust etc that could weaken protective performance left in the inner space 3 In the course of mounting covers make sure that rubber seal rings are not damaged and fasteners are securely sc...

Reviews: