4.5 DATA SAMPLING INTERVAL (FOR PERIODIC DATA)
The interval of data collection and transmission can be set to different periods (e.g.
collect every minute transmit every 10 minutes).
The interval period can be set using the “T2M-DUAL management tool” or on the server
remotely. It is recommended that the transmission period be an integer multiple of the
collection period.
TABLE 11 PERIODIC DATA
Tracking Sampling Period
Transmit
• > 2 minutes
• 0 : if GPIO mode
Collect
• > 1 minute
• 0 : if GPIO mode
GPIO Sampling Period
Transmit
• > 2 minutes
Collect
• > 1 minute
4.6 EVENT DATA (NON-PERIODIC DATA)
When the vehicle encounters an event which triggers an alert, the terminal will transmit
the event data immediately to the server.
The table below describes the event data.
TABLE 12 EVENT DATA
No
Event Name
Event Status
1
Vehicle Battery
Disconnection
• In case the vehicle battery is disconnected (e.g. tampering).
• This alert is invoked also when the terminal self-disconnects to
protect the vehicle battery from draining (low voltage)
2
IGN On / Off
• Vehicle IGN On and Off status
3
Low Battery Warning
• In case of internal battery voltage indicates that it will be
exhausted soon.
4
Shock
• When external shocks occurs
5
SIM Error
• When a SAT SIM Error is occurs, it is reported over 3G and vice-
versa
6
Geo-Fence Deviation
• When the vehicle is out of the set geofence.
7
Over Speed
• When the vehicle is over the set speed limit.
8
Overturn
• When the vehicle is overturned.