6. 

Operating the Antenna

 

 
After the cable connections are made, apply power (10-32V DC) to the Power Supply, 
AS03951 and switch it on. 
 
Wait for the SpaceCom IP321 Maritime Antenna to acquire the satellite signal, this takes 
approx. 1 minute.  
Switch the Thuraya IP terminal on when the antenna is ready (see Section 6.1). Let the 
terminal acquire the satellite network as described in the Thuraya IP manual. 

6.1  Satellite Acquisition 

The tracking antenna performs a full hemispherical satellite search to acquire the Thuraya 
satellite every time power is applied. This takes approx. 1 minute. 
 

6.1.1  Blocking of the Satellite 

If blocking of the satellite signal happens, the antenna controller detects loss of the signal 
from the satellite (can occur if large objects block the line-of-sight to the satellite).  
 
The  antenna  controller  will  first  try  to  reacquire  the  satellite  by  turning  around  two  times 
which  usually  will  take  only  a  few  seconds.  If  this  fails  a  full  hemispherical  acquisition  is 
performed  to  reacquire  the  satellite  which  can  take  up  to  1  minute  if  a  satellite  signal  is 
available. If no signal is available the antenna will continue to scan the sky until a signal 
can be acquired. 
 
The  antenna  controller  can  stabilize  the  antenna  at  signal  levels  that  are  lower  than  the 
operational limits of the Thuraya terminal. 
 

6.2  Satellite choice 

The Thuraya satellite system consists of 2 satellites with each satellite having its own 
beacon the antenna can track. In order for the Thuraya IP terminal to have connection to 
the network, the antenna must track the correct satellite. 
 
When the antenna performs a satellite search it will search for both satellites but in most 
covering areas only one satellite is visible and the antenna automatically detects this and 
tracks the visible satellite. 
 
In certain areas both satellites are visible and therefore the antenna can track either of 
them, but only one of them will allow the Thuraya IP to connect to the network. The area 
with both satellites visible is from longitude 60° East to 110° East. 
 
In the case where the antenna tracks the wrong satellite no service will be available.  
The user can redirect the antenna to the other satellite by, within the first 15 minutes after 
powering on the system, toggling the power switch on the antenna power supply, 

Summary of Contents for SpaceCom IP321

Page 1: ...L10 10059 3 Thuraya Telecommunications Company Installation Manual SpaceCom IP321 Maritime Antenna for Thuraya IP terminal...

Page 2: ...llations using the Pole Mount Kit 7 5 3 1 Pole Mount Kit Contents 8 5 3 2 Pole Mount Component Description 8 5 4 Connecting to the Thuraya IP Terminal 10 5 5 Bending Radius of the Coax Cables 12 6 Ope...

Page 3: ...to acquire the satellite and stabilize the antenna using a tracking beacon from the Thuraya satellites This ensures that the antenna is always pointed optimally towards the satellite regardless of sh...

Page 4: ...requency 1626 5 1660 5MHz Max EIRP 16 5 1 dBW Max output from antenna G T 16dB K Terminal Connector SMC connector Supply Voltage To Power Supply AS03951 10 32V DC Power Consumption 60W at 10V DC max E...

Page 5: ...ith the following spectral density 5 20 Hz 0 02G2 Hz 20 150 Hz 3dB octave Single frequency vibration 5 10 Hz with amplitude 2 54 mm 10 15 Hz with amplitude 0 76mm 15 25 Hz with amplitude 0 40mm 25 33...

Page 6: ...S03951 4 Cables for installation 1 15 meter or 25meter coax antenna cable with N connectors 2 1 meter coax interface cable with SMA and SMC connectors 3 1 red black DC cable for the Power Supply AS039...

Page 7: ...structed and the satellite link performance degraded Do not place the antenna close to interfering signal sources or receivers Vibration levels in a typical installation are usually much less than the...

Page 8: ...Washer M5 A4 Part No SPAC M90 10128 5 3 2 Pole Mount Component Description 1 Mounting Pole Part No SPAC M00423 is a piece of standard tube made from a stainless steel alloy The pole is part of the ven...

Page 9: ...d for the u bolts SPAC M01619 refer to Figure 3 Nuts are to be tightened to 8Nm Remember to use the washers M90 10062 as shown in Figure 3 11 Screws Part No SPAC M90 10205 are M6 metric 40mm long scre...

Page 10: ...onnected with the Power Supply AS03951 by a single coaxial cable with an N male connector at each end The cable carries receive and transmit L band signals as well as DC power to the antenna A separat...

Page 11: ...1 meter coax cable from the Power Supply AS03951 to the terminal active external antenna connector see Figure 5 Remember to tighten the connecter in both ends with 1Nm force To terminal active extern...

Page 12: ...converter in the Power Supply AS03951 is isolated from the vessel s 0V The external GPS antenna and Thuraya IP power supply cable must be connected according to the Thuraya IP manual 5 5 Bending Radiu...

Page 13: ...ute if a satellite signal is available If no signal is available the antenna will continue to scan the sky until a signal can be acquired The antenna controller can stabilize the antenna at signal lev...

Page 14: ...14 AS03951 This will redirect the antenna to track the beacon of the other satellite visible It is not necessary to power off the Thuraya IP terminal...

Page 15: ...e 6 b If Satellite Antenna Type differs from Active External go to point 3 else the antenna is detected and tracking a satellite go to point 4 3 The terminal has not detected the antenna Perform the f...

Page 16: ...16 Figure 6 Thuraya IP terminal web interface Check for antenna type...

Page 17: ...oducts may contain remanufactured parts equivalent to new in performance or may have been subject to incidental use IN NO EVENT WILL SPACECOM BE LIABLE FOR LOSS OF DATA OR FOR DIRECT INCIDENTAL CONSEQ...

Reviews: