adjusted until less than the dimensions of the work piece.
8.
Select“factory parameters”,and then copy the Y-axis Pulse Unit number to the rotate
Pulse unit, input the diameter of the object and the pulse per round. Like below:
Select
“
Rotate Engrave
”
, and then tick
“
Jaw Rotary
”
①
The same as Y-axis pulse
②
5000*2
③
The diameter of the target item
9.
Select "Load" and
“Send file to Machine”, click “Original” and “box” on the display,
please make sure that the material is in the right location and enough space for
working.
10.
Switch on the exhaust system and the cooling system.
For MARS-120, you need to
connect the exhaust system and switch on the power supply by manually. Please
check the water cooling system is working properly; the water is running into and filling
the laser tube. Please do not starts you work if laser tube is
n’t full of water, because
that may led to laser tube damage due to the high temperature.
11. Finally press the START button in the display, to start the engraving process.