Surveillance zones
Transceiver Configuration
9-Nov-00
Page 4-35
If an invalid shape or invalid data is programmed the entire zone is
ignored. When zones overlap the zone with the highest priority
(lowest number) will determine the reporting interval.
4.6.1 Setting up surveillance zones
Purpose:
Control surveillance zones.
Format
: ZOne <options>
The zone has to be created using zone -n before the interval and
positions can be entered.
Note:. The Number of positions in storage queue in fishery menu
item 51 (please see section 4.1.21) must be less than 100 when
usin g surveillance zones ..
Options
-d ["zonenumber"]
Displays the zone configuration. Use "zonenumber" to select a
specific zone.
-i "zonenumber","reporting interval"
Add/Change the reporting interval in a zone
"reporting interval"
= "20" - "65535"
-n "zonenumber","zonetype"
Create a new zone.
Zonetype
Zonetypes
1 -
Circle
2 -
Triangle
3 -
Quadrille
4 -
Pentagon
5 -
Hexagon
6 -
Heptagon