background image

 

Read WARNINGS & SAFETY INSTRUCTIONS before operating machine

 

INSTALLATION 

 

Inspect shipment for damages during transit and unpack 

 

Top engine fuel tank up with clean, fresh, Petrol 

 

WARNING – PLEASE READ SAFETY INSTRUCTIONS FIRST! 

 

 

For portable machines: Connection supply hose to water supply: 

Important: Use hose with minimum 20 mm inside diameter 

Required pressurised water supply (not gravity) with minimum of 10 PSI and ~20% 
more flow that pump flow rate (litres per minute)  

Turn on the water supply (open tap fully). Water will fill the break tank if fitted 

For Skid-mounted units and Trailer-mounted units – ensure tank has enough water and the 
water level is at least above the low level float switch otherwise the engine won’t start 
 

 

Unroll the hose fully ensuring there are no kinks in it 

 

Trigger gun to expel any air in the system 

 

 

LAST CHECKS & START: 

 

Check all hoses are connected and check for damage or water leaks 

 

Check oil level in the pump. The oil sight glass should be HALF full – not more! If oil need 
to be topped up, use SAE10W40 or SAE 15W40 or SAE30 and top up at the Slave Oil 
Tank if fitted, otherwise on the pump itself. 

 

Ensure water supply tap (on portable machines) or tank ball valves are wide open  

 

For the HONDA GX200 – 6.5 hp  &  GX390 – 13 hp engines

  

To Start: 

 

Ensure that the main RED ON/OFF switch is switched to OFF. 

 

Ensure the Choke is ON (Moved fully to the left) when engine is cold 

 

Ensure Fuel is OPEN (Fuel lever moved all the way to the right) 

 

Now take the recoil start handle attached to the recoil rope and give it 2 slow pulls to prime 
engine. 

 

Now switch the main RED ON/OFF switch to ON and give the recoil handle firmly and fast 
fully extended pull. The engine should fire up.  

 

As soon as the engine fires up, turn Choke to the OFF position by pushing the choke lever 
all the way to the left. 

 

NOTE: engine revs is locked. Do not attempt to unlock or change this. It will void your 
warranty! Engine is set to run at top torque curve – set up to optimal revs for the pressure 
and flow. 

 

 

The engine is now running, pump is pumping and water is running in by-pass. 

 

Pull the trigger on the gun by pointing the lance in a safe direction.  

 

When the trigger is released, the pump is still pumping and water is in by-pass.  

 
 

To Shut down: 

 

Flick the main red ON/OFF switch back to the OFF position 

 

Turn the fuel supply off by pushing the fuel supply lever all the way to the LEFT. 

 

Turn water supply off and disconnect (Portable units) 

 

Squeeze trigger a few times to ensure no pressure is stored in the hose. 

 

Roll out the hose and then roll it up avoiding any kinks 

 

 

For the HONDA GX630 – 20 hp engine: 

To Start: 

 

Ensure that the fuel tap on the bottom of the stainless steel fuel tank is open and that the 
fuel tank is full. 

Summary of Contents for P13C-36C

Page 1: ...R 30C TO P20R 43C T P20R 43C TO Index Page 2 Technical data Specifications 3 4 Installation Start up 5 Operating Tips Shutting down Regular Checks 6 7 Maintenance Schedule 8 9 Trouble Shooting Guide 1...

Page 2: ...50 psi 18 lpm Set up de rated pressure flow 1600 psi 14 lpm 3500 psi 17 lpm 2600 psi 18 lpm 3000 psi 18 lpm Or 3500psi 18 lpm 3000 psi 18 lpm Vs 3000 3500 psi Nozzle size at set up pressure 15060 1504...

Page 3: ...To Start Ensure that the main RED ON OFF switch is switched to OFF Ensure the Choke is ON Moved fully to the left when engine is cold Ensure Fuel is OPEN Fuel lever moved all the way to the right Now...

Page 4: ...at comfortable revs set to the power requirement for the pump pressure and flow DO NOT ALTER REMEMBER Check for leaks and Oil Levels DAILY OPERATING CLEANING TIPS 1 Using a Fan Jet first blast off hea...

Page 5: ...ure safety protective gear is used and in good state of repair Ensure Safety MEDIC ALERT Card is handy Prolonged by pass Leaving the unit in prolonged by pass machine is switched on but trigger is not...

Page 6: ...90 YES YES YES 10 Strip and Refurbish pump Replace Plunger Rod Oil Seals 3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only...

Page 7: ...swivels H P Hoses are usually uneconomical to repair Replace as necessary Remember to check filters regularly and clean under running water The correct procedure for replacing the filter mesh in the s...

Page 8: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Page 9: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Page 10: ...lost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Page 11: ...r Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head face eye protection wet weather gear boots and gloves which is particularly important where hot water or aggressi...

Page 12: ...ling the safety tag off the machine and taking it with you to the doctor Tell the doctor what type of project task was being performed at the time of the injury making special note of any chemicals th...

Page 13: ...cement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable...

Page 14: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Page 15: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Page 16: ......

Page 17: ...spring Molla valvola 6 20 0604 00 Valve cage Gabbia valvola 6 21 1400 02 Washer Rosetta 6 5 8 4 22 1802 07 Hexagonal screw Vite M6x18 8 4 23 0205 01 Shaft protector Protezione albero 1 24 0500 09 Open...

Page 18: ...52 0500 15 Motor flange Flangia motore 1 Part available Particolare disponibile in kit only solo in kit Part available Particolare disponibile in kit also anche in kit Part Number Description Codice...

Page 19: ......

Page 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Page 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Reviews: