ThoroughClean E15i-43C Operator'S Manual Download Page 9

 

Read WARNINGS & SAFETY INSTRUCTIONS before operating machine 

 

 

 

HIGH PESSURE, HIGH VELOCITY WATER IS DANGEROUS! 

  
 
GENERAL PRESSURE CLEANER WARNINGS AND SAFETY PRECAUTIONS 

 

 

When shutting down, always turn off machine, turn off water at the source and trigger the 
gun pointing the lance in a safe direction to release any in-line stored pressure - before 
disconnecting hoses or working on machine.  

 

Never aim high pressure water jet at anyone, at animals or at fragile items - injury or 
damage could result.  

 

Always be aware of overhead cables, run-off water, slippery surfaces and by-
standers! 

 

Never allow untrained adults or minors use of the equipment.  

 

Never use the machine if there are any leaks on the high pressure delivery side of the 
pump.  

 

Read and observe the manufacturer's instructions if chemicals are being used.  

 

The “recoil” on larger machines is positive - lean forwards and brace yourself to take it 
up!!!   

 

NEVER HIGH PRESSURE BLAST THE FOLLOWING:

  any electrical components, 

motors / switchgear or electrical boxes as injury or death may result.  

 

Never water blast any fuel caps or oil caps and water can get into breather holes and 
contaminate fuel or water. Never blast water directly into seals / bearings on shafts where 
water penetration would be detrimental.  

 

NEVER WATER BLAST

: fragile items / surfaces that may be damaged by high velocity 

water. Always carefully test on a small area first.  

 

ALWAYS WEAR PROTECTIVE GEAR (PPE)

  i.e. Head, face, eye protection, wet 

weather gear, boots and gloves - which is particularly important where hot water or 
aggressive chemicals are being used or where whet sandblasting is used.  

 

Keep hands, feet and hair away from all moving parts.  

 

Never leave machine running unattended.  

 

EXTREME DANGER

  -  never adjust engine speed (RPM) or safety by-pass valve in an 

attempt to increase pressure!  

 

Barricade off immediate work area - restrict access - erect hazard warning signs.  

 

Never use high pressure water cleaner without protective canvas sheaths on operator 
end of high pressure hose as a high pressure leak can injure operator.  

 

In commercial / industrial sites class 'b' units (pressures over 5,000 PSI) should have 
additional operators allocated as safety observer / machine minder subject to work 
conditions / environment. This is a responsibility of the 'site occupier' to determine.   

 

If two / three operators are working they should be physically separated by partitions / 
barriers.  

 

Prior to high pressure water blasting, check location’s level of emergency /first aid. 

 

All machines are fitted with 

MEDIC ALERT

 tags. If a high pressure water injury occurs 

which need medical attention, pull off machine and give it to the medical practitioner to 
read 

 
 

Summary of Contents for E15i-43C

Page 1: ...4 Operating Tips Shutting down Regular Checks 5 Maintenance Schedule 6 7 Trouble Shooting Guide 8 What can cause expensive damage to your machine 9 WARNINGS SAFETY INSTRUCTIONS 10 MEDIC ALERT Informa...

Page 2: ...18 lpm Set up de rated pressure flow 1100 psi 11 lpm 1100 psi 11 lpm 3000 psi 18 lpm 4000 psi possible 3000 psi 18 lpm 4000 psi possible Nozzle size at set up pressure 15060 15060 15060 15060 Pump Sp...

Page 3: ...t pump flow rate litres per minute Turn on the water supply open tap fully Water will fill the break tank if fitted Unroll the hose fully ensuring there are no kinks in it Trigger gun to expel any air...

Page 4: ...operating pressure If pressure drops over time it may indicate general wear and tear and a service is recommended Air Leaks Especially in suction to pump hoses Repair immediately if found Check for cu...

Page 5: ...t Tag electrical equipment as Specified by Law As required by law 12 CONTROL PANEL Have an Authorised Electrician Fully Function Test Repair or Replace all Electrical Components As required or annuall...

Page 6: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Page 7: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Page 8: ...ost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Page 9: ...enetration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head...

Page 10: ...pecial note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT WARNING TAG AND TAKE THIS TO A MEDICAL...

Page 11: ...able loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits to the consum...

Page 12: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Page 13: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Page 14: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Page 15: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Page 16: ......

Page 17: ......

Page 18: ...lvola 6 23 0900 30 Valve spring Molla valvola 6 24 0604 10 Valve cage Gabbia valvola 6 25 1801 12 Screw Vite M6x16 12 26 0203 18 Bearing cover Coperchio cuscinetto 2 27 0205 02 Bearing seal Cappellott...

Page 19: ...istone 18 1 2600 43 Complete seal Packing 18 mm 2600 43 Pacco completo Guarnizioni pistone 18 3 2614 05 Plunger 18 mm 2614 05 Pistone 18 3 2600 28 Complete Valve 2600 28 Valvola completa 1 2608 26 Plu...

Page 20: ...0 0 0 03 3 3 36 6 6 6 0 0 0 0 0 0 0 00 0 0 00 0 0 0 2 2 2 2 8 8 8 8 5 5 5 50 0 0 0 2 2 2 2 XLT3816S 160 2320 38 46 10 12 1000 1200 15 9 19 0 11 7 14 0 XLT5015 150 2175 50 60 13 2 15 8 1450 1740 18 8 2...

Page 21: ...LT3816S XLT1830 XLT2230 XLT2530 XLT2520 XLT2730 XLT3025 XLT3020 XLT3325 XLT3517 XLT4017 XLT4014 XLT4317 XLT5015 XLT5415 23 24 25 26 27 28 29 30 27 31 26 32 33 24 23 34 35 36 37 38 39 40 41 42 43 44 45...

Page 22: ...3 2601 14 Complete seal Packing 25 mm 3 2601 16 Complete seal Packing 28 mm 3 2601 30 Plunger 20 mm 3 2601 29 Plunger 22 mm 3 2601 17 Plunger 25 mm 3 2601 18 Plunger 28 mm 3 2600 10 Complete Valve 6 2...

Page 23: ...65 U seal dia 28 mm 3 8 1601 33 Brass plug G3 4 1 9 0603 11 Copper washer 3 4 1 1602 39 Manifold housing 28 25 1 1602 40 Manifold housing 22 20 1 0601 66 O Ring 2 62x25 7 6 0601 18 O Ring 2 62x21 89...

Page 24: ...Bonded seal 3 1200 32 Plunger 20 mm 3 1200 34 Plunger 22 mm 3 1200 33 Plunger 25 mm 3 1200 30 Plunger 28 mm 3 37 1400 57 Copper spacer 3 38 0003 32 Plunger rod 3 39 1502 07 Connecting rod pin 3 40 010...

Page 25: ...1 1 2 2 3 3 4 4 5 5 6 6 A A B B C C D D E3R 22C Circuit Diagram A Ferero 3 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date M...

Page 26: ...2 2 3 3 4 4 5 5 6 6 A A B B C C D D E15I Circuit Diagram A Ferero D Cover 22 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date L1 L2 L3 30 VA 415 240 2A C1 EOL M EOL STOP START C1...

Page 27: ...12 Designed by Checked by Approved by Date 1 1 Edition Sheet Date 1 2 3 415V 24V 2A EOL R1 STOP START C1 C1 R1 4 5 C1 EOL M 1 2 3 Supply 4 5 Water shutdown Instant 6 7 Timed shutdown set to OP T1 T1 6...