ThoroughClean E15i-43C Operator'S Manual Download Page 7

 

Fair Wear / Tear? 

Check – Replace HP Jet 

Check Recent 
Activity/Usage 

Suction/Delivery HP Outlet Valves 
Worn 

Check – Replace 

Therefore Check suction 
Filters 

Unloader Valve Worn 

Replace as required 

  

Piston Seals Worn 

Replace as required 

Check Big Ends for Piston 
Slap 

Piston Cracked 

Replace as required 

Check Big Ends for Piston 
Slap 

”O” Rings Failed/Leaking 

Replace as required 

  

”Big End” Worn 

Replace as required 

  

 PSI LOW AFTER 

PERIOD OF USE 

Drive Belts Loose (if belt driven) 

Check / Tighten 

  

Air in Suction / Pump Cavitating 

Identify Air Ingress/Seal 

  

Problem with pump-motor 
connection 

Check gearbox or coupling 

  

Broken or Weak Suction Valve 
Spring 

Check – Replace – As Set 

  

Valves Clogged/Sticking 

Check – Replace – As Set 

  

Worn Main Crankshaft Bearings 

  

Probably Uneconomical to 
Repair 

PUMP VERY 

“NOISY” 

Inlet Water Temp over 75 deg 
Celsius 

Reduce inlet Water Temp 

Left in By-Pass for 
excessively long periods?  

Piston to Crankcase Oil Seals Worn 

Check and Replace 

Look for Oil under Pump – 
Low Pump Oil 

Condensation from High Ambient 
Humidity 

Replace oil more frequently 

  

Piston Seals Worn/Cracked Piston 

Check – Replace 

  

OIL IN PUMP 

EMULSIFIED/ 

CONTAMINATED 

BY WATER 

 (water in the 

oil) 

Water Blasted into Pump via 
Breather Cap during Cleaning 

Exercise Care 

  

H.P. Piston Seals Worn or 

Check and Replace Seal Pack 

  

Worn Plunger  

Replace Plunger 

  

Worn Plunger Stop Seal 

Replace Seal 

  

 WATER 

DRIPPING FROM 

UNDER PUMP 

(Between 

crankcase and 

manifold 

housing) 

“O” Rings in Plunger Retaining Bolt 
Worn 

Check and Replace 

  

 OIL DRIPPING 
FROM UNDER 
PUMP 
(Between 
crankcase and 
manifold 
housing) 

Piston to Crankcase (Plunger Shaft) 
Oil Seals Worn 

Check and Replace 

Check Pump for Low Oil 
therefore “Big End” 
Damage 

Accumulator Failed 

Check – Replace 

  

Worn Seals (Wet end seals) 

Replace if worn 

  

Worn Plunger Seals 

Replace if worn 

  

In/Out Pump Valves Worn 

Check – Replace 

  

Valves full of scale/dirt 

Clean or replace 

  

Pistons Cracked 

Check – Replace 

  

Low Water Supply 

Increase supply 

  

EXCESSIVE 

VIBRATION/ 

PULSATIONS IN 

HP DELIVERY 

LINE 

Gudgeon Pin in Conrod  Stretched 

Check – Replace 

  

WATER FILTER 

MESH IS 

CRUSHED WHEN 

REPLACED 

Incorrect replacement procedure 
on Grey NY126 Water Filters with 
Blue or Red mesh tube 

First insert mesh tube tightly into 
the fixed black head of filter 
assembly and then screw on grey 
cover /cup tightly. 

 For small black filters, first 
insert mesh tube into cover 
/cup and then screw onto 
fixed part. 

 

Summary of Contents for E15i-43C

Page 1: ...4 Operating Tips Shutting down Regular Checks 5 Maintenance Schedule 6 7 Trouble Shooting Guide 8 What can cause expensive damage to your machine 9 WARNINGS SAFETY INSTRUCTIONS 10 MEDIC ALERT Informa...

Page 2: ...18 lpm Set up de rated pressure flow 1100 psi 11 lpm 1100 psi 11 lpm 3000 psi 18 lpm 4000 psi possible 3000 psi 18 lpm 4000 psi possible Nozzle size at set up pressure 15060 15060 15060 15060 Pump Sp...

Page 3: ...t pump flow rate litres per minute Turn on the water supply open tap fully Water will fill the break tank if fitted Unroll the hose fully ensuring there are no kinks in it Trigger gun to expel any air...

Page 4: ...operating pressure If pressure drops over time it may indicate general wear and tear and a service is recommended Air Leaks Especially in suction to pump hoses Repair immediately if found Check for cu...

Page 5: ...t Tag electrical equipment as Specified by Law As required by law 12 CONTROL PANEL Have an Authorised Electrician Fully Function Test Repair or Replace all Electrical Components As required or annuall...

Page 6: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Page 7: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Page 8: ...ost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Page 9: ...enetration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head...

Page 10: ...pecial note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT WARNING TAG AND TAKE THIS TO A MEDICAL...

Page 11: ...able loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits to the consum...

Page 12: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Page 13: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Page 14: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Page 15: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Page 16: ......

Page 17: ......

Page 18: ...lvola 6 23 0900 30 Valve spring Molla valvola 6 24 0604 10 Valve cage Gabbia valvola 6 25 1801 12 Screw Vite M6x16 12 26 0203 18 Bearing cover Coperchio cuscinetto 2 27 0205 02 Bearing seal Cappellott...

Page 19: ...istone 18 1 2600 43 Complete seal Packing 18 mm 2600 43 Pacco completo Guarnizioni pistone 18 3 2614 05 Plunger 18 mm 2614 05 Pistone 18 3 2600 28 Complete Valve 2600 28 Valvola completa 1 2608 26 Plu...

Page 20: ...0 0 0 03 3 3 36 6 6 6 0 0 0 0 0 0 0 00 0 0 00 0 0 0 2 2 2 2 8 8 8 8 5 5 5 50 0 0 0 2 2 2 2 XLT3816S 160 2320 38 46 10 12 1000 1200 15 9 19 0 11 7 14 0 XLT5015 150 2175 50 60 13 2 15 8 1450 1740 18 8 2...

Page 21: ...LT3816S XLT1830 XLT2230 XLT2530 XLT2520 XLT2730 XLT3025 XLT3020 XLT3325 XLT3517 XLT4017 XLT4014 XLT4317 XLT5015 XLT5415 23 24 25 26 27 28 29 30 27 31 26 32 33 24 23 34 35 36 37 38 39 40 41 42 43 44 45...

Page 22: ...3 2601 14 Complete seal Packing 25 mm 3 2601 16 Complete seal Packing 28 mm 3 2601 30 Plunger 20 mm 3 2601 29 Plunger 22 mm 3 2601 17 Plunger 25 mm 3 2601 18 Plunger 28 mm 3 2600 10 Complete Valve 6 2...

Page 23: ...65 U seal dia 28 mm 3 8 1601 33 Brass plug G3 4 1 9 0603 11 Copper washer 3 4 1 1602 39 Manifold housing 28 25 1 1602 40 Manifold housing 22 20 1 0601 66 O Ring 2 62x25 7 6 0601 18 O Ring 2 62x21 89...

Page 24: ...Bonded seal 3 1200 32 Plunger 20 mm 3 1200 34 Plunger 22 mm 3 1200 33 Plunger 25 mm 3 1200 30 Plunger 28 mm 3 37 1400 57 Copper spacer 3 38 0003 32 Plunger rod 3 39 1502 07 Connecting rod pin 3 40 010...

Page 25: ...1 1 2 2 3 3 4 4 5 5 6 6 A A B B C C D D E3R 22C Circuit Diagram A Ferero 3 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date M...

Page 26: ...2 2 3 3 4 4 5 5 6 6 A A B B C C D D E15I Circuit Diagram A Ferero D Cover 22 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date L1 L2 L3 30 VA 415 240 2A C1 EOL M EOL STOP START C1...

Page 27: ...12 Designed by Checked by Approved by Date 1 1 Edition Sheet Date 1 2 3 415V 24V 2A EOL R1 STOP START C1 C1 R1 4 5 C1 EOL M 1 2 3 Supply 4 5 Water shutdown Instant 6 7 Timed shutdown set to OP T1 T1 6...