Display Indications, Common Problems, Possible Solutions / Indicacion, Causa Posible, Solucion  Posible

LOW DC INPUT VOLTAGE  (Below 10Vdc) 

Battery Voltage too low, Check or Recharge (battery) Power Source

Inadequate power being delivered to the inverter or excessive voltage drop. Use heavier gauge wire 

See  “Installation Specifications” in users manual

APAGADO DE BAJA ENTRADA DE VOLTAJE

Voltaje de la fuente (batería ) demasiado baja Recargue o substituya la ( batería) Fuente de alimentación

Potencia inadecuada entregado al inversor o excesiva caída de Voltage .

Consulte “Especificaciones de instalación” en el manual del usuario

HIGH DC INPUT VOLTAGE ( Above 16Vdc)

Battery Voltage is too high, Check for fault with battery charging system 

APAGADO DE ALTA ENTRADA DE VOLTAJE

Voltaje de la batería es demasiado alto, Compruebe si hay fallas en el sistema de carga de la batería

OVERLOAD SHUTDOWN 

Excessive start-up load. Power tool (or appliance ) draws too much voltage; and cannot be used with your inverter 

Inadequate power being delivered to the inverter  or excessive voltage drop . Use heavier Gauge wire.

See  “Installation Specifications” in users manual.

APAGADO DE SOBRECARGA

Excesivo Carga de arranque.

Potencia inadecuada entregado al inversor o excesiva caída de Voltage .

Consulte “Especificaciones de instalación” en el manual del usuario.

OVER TEMPERATURE 

Inverter is too hot (thermal shutdown mode) Allow Inverter to cool. Check for adequate ventilation. 

Reduce the load on the inverter to rated continuous output.

APAGADO DE ALTA TEMPERATURA

Inversor está demasiado caliente.

Permita inversor  que se enfríe . Compruebe si hay una ventilación adecuada para el inversor .

Reduzca la carga en el inversor .

GROUND FAULT PROTECTION / SHORT CIRCUIT PROTECTION  

Inverter senses a leakage current on the ground terminal or short circuit current  on the AC sockets. Unplug the AC appliance or 

power tool. Turn off the inverter, disconnect unit from any 12 VDC power source. Check the appliance or power tool and cord.

PROTECCION DE FUGA

Inversor detecta una corriente de fuga.

Inversor detecta corriente de cortocircuito.

Desenchufe el aparato de CA o herramienta eléctrica

E 01

E 02

E 03

E 04

E 05

No FUNCTION - (If inverter digital display does not illuminate.)

Check and make sure the inverter is properly connected  to (battery) Power Source .

See  “Installation Specifications” in users manual.

Summary of Contents for THMS-1000

Page 1: ...BE REPRODUCED OR TRANSFERRED TO DOCUMENTS OR DISCLOSED TO OTHERS OR USED FOR MANUFACTURING OR ANYOTHER PORPUSE WITHOUT PRIOR WRITTEN PERMISSION THMS1000 MODEL DATE 5 11 2015 PREPARED BY Jose Illidge...

Page 2: ...er Gauge wire See Installation Specifications in users manual APAGADO DE SOBRECARGA Excesivo Carga de arranque Potencia inadecuada entregado al inversor o excesiva ca da de Voltage Consulte Especifica...

Page 3: ...inder Disk 4 1 2 Shop Vac Hand Drill Jigsaw Fax Machine Laser Printer Microwave Oven Computer Desktop Printer Sewer Camera Lights TV s up to 27 Video Monitors Recharger Battery Power Tools DVD Camcord...

Page 4: ...15 feet 2 0 20 Feet 3 0 5 feet 1 0 10 Feet2 0 15 feet 3 0 20 Feet 3 0 5 feet 3 0 10 Feet 3 0 15 feet 3 0 20 Feet 4 0 THI 200 THI 200 THI 200 THI 500 THI 500 THC 35 THC 45 THC 55 THC 75 THC 100 THC 35...

Page 5: ...PROFESSIONAL GRADE POWER INVERTER SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE Copyright 2015 THOR Manufacturing Instruction Manual and Warranty Information THMS 1000 THMS 1500 THMS 2000 THMS 300...

Page 6: ...hazardous situation which if not avoided may result in property damage RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of...

Page 7: ...ATTERY MANUFACTURER AND THE MANUFACTURER OF ANY EQUIPMENT YOU INTEND TO USE WITH THIS UNIT REVIEW CAUTIONARY MARKINGS ON THESE PRODUCTS AND ON ENGINE TABLE OF CONTENTS Introduction 3 Features 4 Contro...

Page 8: ...verter happens to shut down from over load or over temperature condition or abnormal input voltages The ON OFF Switch turns the inverter ON and OFF The switch can also be used to force reset of invert...

Page 9: ...ey are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters will not correctly read the RMS voltage of a modified sine wave Non TRUE RMS met...

Page 10: ...appliances and tools Most of these appliances use a separate charger or transformer that is plugged into an AC receptacle Your inverter is capable of running most chargers and transformers POWER SOURC...

Page 11: ...this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt hours of energy use the total run...

Page 12: ...Never place items on or over the inverter during operation SAFE Do not locate inverters in an area room or compartment where explosives or flammable fumes might be present such as engine rooms engine...

Page 13: ...cable length but don t do any cutting at this time refer to the diagram in the Battery Configuration section of this Instruction Manual 4 Using an appropriate AWG cable refer to the Specifications sec...

Page 14: ...light Having checked and corrected these conditions if necessary refer to the Service Information section of this Instruction Manual for assistance if problems persist CAUTION Loose connectors may ca...

Page 15: ...inverter from any power source when not in use Operation of the USB Charging Port 1 Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual Make sure the...

Page 16: ...Recargue o substituya la bater a Fuente de alimentaci n Potencia inadecuada entregado al inversor o excesiva ca da de Voltage Consulte Especificaciones de instalaci n en el manual del usuario HIGH DC...

Page 17: ...vacuum cleaner hose vacuum the air slots and fan area 4 Clean the outside of the unit using a damp not wet cloth 5 Wipe unit surfaces thoroughly with a dry cloth 6 Resume operation LIMITED TWO YEAR HO...

Page 18: ...of the original sales receipt to THOR Manufacturing 7050 W Palmetto Park Rd Suite 4 Boca Raton FL 33433 SPECIFICATIONS SPECIFICATIONS THMS1000 THMS1500 THMS2000 THMS3000 Output Voltage Voltage De Sli...

Reviews: