background image

RETURN / REPAIR POLICY

Defective products, other than accessories, may be returned postage prepaid to THOR POWER PRODUCTS. Any 

defective product, other than accessories, that is returned to THOR POWER PRODUCTS within 30 days of the 

date of purchase will be replaced free of charge. If such a product is returned more than 30 days but less than two 

year from the purchase date, THOR POWER PRODUCTS will repair the unit or, at its option, replace it free of 

charge. If the unit is repaired, new or reconditioned replacement parts may be used, at THOR POWER RPODUCTS 

option. A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired or 

replaced unit will then be warranted under the terms of the remainder of the warranty period. The customer is 

responsible for the shipping charges on all returned. During the warranty period, THOR POWER PRODUCTS. will 

be responsible for the return shipping charges.

WARRANTY ACTIVATION: 

Please complete the Warranty Activation Card and mail to THOR Manufacturing. Enter the model number and 

product type and serial number. All THOR Manufacturing products must be registered within 30 days of purchase to 

activate this warranty. Mail the completed registration form, along with a copy of the original sales receipt to: THOR 

Manufacturing, 7050 W. Palmetto Park Rd., Suite 4, Boca Raton, FL 33433.

SPECIFICATIONS

SPECIFICATIONS

THMS1000

THMS1500

THMS2000

THMS3000

Output Voltage / Voltage De 

Slida 

120 +- 5 Vac / 120 

+- 5 VCD

120 +- 5 Vac / 120 

+- 5 VCD

120 +- 5 Vac / 120 

+- 5 VCD

120 +- 5 Vac / 120 

+- 5 VCD

Output Frequency / Frecuencia 

De Salida

60 Hz

60 Hz

60 Hz

60 Hz

Output Waveform / Forma De 

Onda 

Modified Sine Wave 

/ Onda Sinusoida 

Modificada

Modified Sine Wave 

/ Onda Sinusoida 

Modificada

Modified Sine Wave 

/ Onda Sinusoida 

Modificada

Modified Sine 

Wave / Onda 

Sinusoida 

Modificada

Max. Continuous Active Power 

Output  / Slida De Corriente 

Continua 

1000 Watt / 1000 

Vatios 

1500 Watt / 1500 

Vatios 

2000 Watt / 2000 

Vatios 

3000 Watt / 3000 

Vatios 

Max. Active Surge Power 

Output (<.5 Sec) / Salida De 

Corriente Para Pico 

2000 Watt / 2000 

Vatios 

3000 Watts / 3000 

Vatios 

4000 Watts / 4000 

Vatios 

6000 Watts / 6000 

Vatios 

Peak Efficiency  / Punto Mas 

Alto De Eficiencia 

>85 %

>85 %

>85 %

>85 %

DC Input Voltage Range / 

Rango De Voltage De Entrada

10.5 To 16 (+/- 0.5) 

VDC / 10.5-16 (+/- 

0.5) VCD

10.5 to 16 (+/- 0.5) 

VDC / 10.5-16 (+/- 

0.5) VCD

10.5 to 16 (+/- 0.5) 

VDC / 10.5-16 (+/- 

0.5) VCD

10.5 to 16 (+/- 0.5) 

VDC / 10.5-16 (+/- 

0.5) VCD

Max DC Input Current  / 

Corriente De Entrada 

85 - 120 Amps DC 

(8.0  - 9.5 Amps Ac) 

- 85 - 120 Amperios 

(8.0 - 9.5 Amperios)

127 - 179 Amps DC 

(11.6  - 14.5 Amps 

AC) - 127 -179 

Amperios (11.6 - 

14.5 Amperios) 

175 - 230 Amps DC 

(16.0  - 18.5 Amps 

AC) - 175 - 230 

Amperios (16.0 - 

18.5 Amperios) 

260 - 330 Amps 

DC (24.0  - 28.0 

Amps AC) - 260 - 

330 Amperios C.D 

(24.0 - 28.0 

Amperios C.A)

Summary of Contents for THMS-1000

Page 1: ...BE REPRODUCED OR TRANSFERRED TO DOCUMENTS OR DISCLOSED TO OTHERS OR USED FOR MANUFACTURING OR ANYOTHER PORPUSE WITHOUT PRIOR WRITTEN PERMISSION THMS1000 MODEL DATE 5 11 2015 PREPARED BY Jose Illidge...

Page 2: ...er Gauge wire See Installation Specifications in users manual APAGADO DE SOBRECARGA Excesivo Carga de arranque Potencia inadecuada entregado al inversor o excesiva ca da de Voltage Consulte Especifica...

Page 3: ...inder Disk 4 1 2 Shop Vac Hand Drill Jigsaw Fax Machine Laser Printer Microwave Oven Computer Desktop Printer Sewer Camera Lights TV s up to 27 Video Monitors Recharger Battery Power Tools DVD Camcord...

Page 4: ...15 feet 2 0 20 Feet 3 0 5 feet 1 0 10 Feet2 0 15 feet 3 0 20 Feet 3 0 5 feet 3 0 10 Feet 3 0 15 feet 3 0 20 Feet 4 0 THI 200 THI 200 THI 200 THI 500 THI 500 THC 35 THC 45 THC 55 THC 75 THC 100 THC 35...

Page 5: ...PROFESSIONAL GRADE POWER INVERTER SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE Copyright 2015 THOR Manufacturing Instruction Manual and Warranty Information THMS 1000 THMS 1500 THMS 2000 THMS 300...

Page 6: ...hazardous situation which if not avoided may result in property damage RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of...

Page 7: ...ATTERY MANUFACTURER AND THE MANUFACTURER OF ANY EQUIPMENT YOU INTEND TO USE WITH THIS UNIT REVIEW CAUTIONARY MARKINGS ON THESE PRODUCTS AND ON ENGINE TABLE OF CONTENTS Introduction 3 Features 4 Contro...

Page 8: ...verter happens to shut down from over load or over temperature condition or abnormal input voltages The ON OFF Switch turns the inverter ON and OFF The switch can also be used to force reset of invert...

Page 9: ...ey are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters will not correctly read the RMS voltage of a modified sine wave Non TRUE RMS met...

Page 10: ...appliances and tools Most of these appliances use a separate charger or transformer that is plugged into an AC receptacle Your inverter is capable of running most chargers and transformers POWER SOURC...

Page 11: ...this read the labels on the equipment to be operated 2 Estimate the number of hours the equipment will be in use between battery recharges 3 Determine the total watt hours of energy use the total run...

Page 12: ...Never place items on or over the inverter during operation SAFE Do not locate inverters in an area room or compartment where explosives or flammable fumes might be present such as engine rooms engine...

Page 13: ...cable length but don t do any cutting at this time refer to the diagram in the Battery Configuration section of this Instruction Manual 4 Using an appropriate AWG cable refer to the Specifications sec...

Page 14: ...light Having checked and corrected these conditions if necessary refer to the Service Information section of this Instruction Manual for assistance if problems persist CAUTION Loose connectors may ca...

Page 15: ...inverter from any power source when not in use Operation of the USB Charging Port 1 Connect the inverter to a functioning 12 volt DC power source as described in this Instruction Manual Make sure the...

Page 16: ...Recargue o substituya la bater a Fuente de alimentaci n Potencia inadecuada entregado al inversor o excesiva ca da de Voltage Consulte Especificaciones de instalaci n en el manual del usuario HIGH DC...

Page 17: ...vacuum cleaner hose vacuum the air slots and fan area 4 Clean the outside of the unit using a damp not wet cloth 5 Wipe unit surfaces thoroughly with a dry cloth 6 Resume operation LIMITED TWO YEAR HO...

Page 18: ...of the original sales receipt to THOR Manufacturing 7050 W Palmetto Park Rd Suite 4 Boca Raton FL 33433 SPECIFICATIONS SPECIFICATIONS THMS1000 THMS1500 THMS2000 THMS3000 Output Voltage Voltage De Sli...

Reviews: