background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H-DVB-S2X-MOD 

DVBS2X Satellite Modulator

 

Revision 2018 

 

 

 

 

 

Summary of Contents for H-DVB-S2X-MOD

Page 1: ...H DVB S2X MOD DVBS2X Satellite Modulator Revision 2018...

Page 2: ...IN THE BOX 8 2 2 INSTALLATION PREP 8 2 2 1 Device s Installation Flow Chart Illustrated as following 8 2 2 2 RackRoom Headend Install 8 2 2 3 Grounding Requirement 9 2 3 POWER AND GROUND 10 2 4 SIGNAL...

Page 3: ...part of this document may be reproduced in any form without the written permission of Thor Broadcast The contents of this document are subject to revision without notice due to continued progress in m...

Page 4: ...the newest S2X standard used in a wide variety of application like broadcasting news services broadband satellite applications Fully compliant with DVB S EN300 421 DVB S2 EN302 307 1 and DVB S2X EN 3...

Page 5: ...ellation QPSK QPSK 8PSK 16APSK 32APSK QPSK 8PSK 8APSK 16APSK 32APSK FEC Convolution Rate 1 2 2 3 3 4 5 6 7 8 QPSK 1 2 3 5 2 3 3 4 4 5 5 6 8 9 9 10 8PSK 3 5 2 3 3 4 5 6 8 9 9 10 16APSK 2 3 3 4 4 5 5 6...

Page 6: ...ront Panel Illustration 1 2 3 4 5 6 1 LCD Screen 2 Indicators Power indicates power connection Alarm indicates errors Ext 10M indicates 10MHz outer reference clock is applied TS Overflow indicates the...

Page 7: ...iber com http www thorbroadcast com Rear Panel Illustration 1 2 3 4 5 6 7 1 ASI Input ports 3 ports for backup 2 External 10Mhz Reference Clock Input and loop through 3 Data Port 4 Network Interface N...

Page 8: ...installation rack room or Headend Install Modulator Connect signal cables Connecting communication port if it is necessary 2 2 1 Device s Installation Flow Chart Illustrated as following Connecting G...

Page 9: ...nufacturer s warranty After installation securely stow away all loose cables external antenna and others Be careful when connecting a power source to the device Do not operate in wet or damp areas Mak...

Page 10: ...et while inserting the other end to AC power Connect Grounding Wire When the device solely connects to protective ground it should not share the same ground with any other devices If the device shares...

Page 11: ...cel the lock state After pressing the lock key the LCD will display the current configuring state 3 1 Main Interface After switching on the modulator the LCD screen will display the device name real t...

Page 12: ...system displays following pages 2 1 Modulate Mode 2 2 REF Clock Set 2 3 Input Mode 2 4 IP Input Set 2 5 Symbol Rate 2 6 Roll Off 2 7 FEC Rate 2 8 Pilot Insert 2 9 Parse Program 2 10 Biss Setting 3 2 2...

Page 13: ...reference clock Auto The modulator will preferably select the external 10MHz input if it exists Otherwise the modulator will select the internal 10MHz crystal oscillator s output as reference clock I...

Page 14: ...and output Choose Normal as the input mode under 2 3 1 and IP as the source port under 2 3 2 it needs to configured in the IP parameters under 2 4 IP Input Set according to the actual IP source to rec...

Page 15: ...ent modulate modes DVB S DVB S2 DVB S2X and constellations have different FEC rate options Refer to specifications table in Chapter 1 for details 3 2 2 8 Pilot Insert This menu item is applicable to D...

Page 16: ...BISS scrambling function Mode 1 When the modulator works under Mode 1 select and scramble the input programs manually by entering submenu 2 10 2 and set SW data at submenu 2 10 4 input 12 characters f...

Page 17: ...item ENTER and LEFT RIGHT to set the parameters The system displays following page 3 1 IF Frequency 3 2 IF Level ATT 3 3 Spec Invert 3 4 IF Output 3 2 3 1 IF Frequency Setting After entering the subme...

Page 18: ...output invert or not 3 3 Spec Invert normal 3 3 Spec Invert 1 2 normal invert 3 2 3 4 IF Output 3 4 IF Output SINGLE 3 4 IF Output 01 03 SINGLE MODU OFF You can set the IF output mode for different ap...

Page 19: ...n to choose this item Enter and Left Right to set the parameters The system displays following pages 4 1 IP Address 4 2 Subnet Mask 4 3 Gateway 4 4 MAC Address 4 5 Default Web 4 6 Data Port Note The M...

Page 20: ...Mask 255 255 255 000 4 3 Gateway 192 168 000 001 4 4 MAC Address 20 17 10 30 11 00 4 5 Default Web User NO Yes 4 6 1 Service IP 4 6 2 Subnet Mask 4 6 3 Gateway 4 6 4 MAC Address 4 6 1 IP Address 192...

Page 21: ...Default NO YES Restore the device into the last saved configuration by choosing 6 1 and restore the device into factory configuration by choosing 6 2 3 2 7 Factory Debug After entering the submenu by...

Page 22: ...H DVB S2X MOD Thor Fiber 2018 Tel 800 521 8467 Email sales thorfiber com http www thorbroadcast com SW x xx HW x x...

Page 23: ...s device is 192 168 0 136 We can modify the IP through the front panel Connect the PC Personal Computer and the device with included net cable and use ping command to confirm they are on the same netw...

Page 24: ...the interface where users can System information Input information It automatically displays the signal source input channel Input information It automatically displays the signal source real time bi...

Page 25: ...on up side of the webpage click CID Settings it displays the NIT table which is a very important table for describing the network and TS Set the parameters of the output NIT table and check the NIT CI...

Page 26: ...oad From the menu on left side of the webpage click Saveload it displays the screen as shown in Figure 7 where to save or restore your configurations Figure 7 System Backup From the menu on left side...

Page 27: ...the menu on left side of the webpage click Password it displays the screen as shown in Figure 9 where to reset the login info for the device Figure 9 System Network From the menu on left side of the w...

Page 28: ...aking sure the unit has plenty of ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the AC input within the power supply and ensure it is working the conn...

Page 29: ...l number and issues must be identifiable 3 RMA and PDF RMA form must be enclosed in the package 4 Please pack the unit in its original container If the original container is no longer available please...