![THOR GE559-N Assembly, Installation And Operation Instructions Download Page 9](http://html1.mh-extra.com/html/thor/ge559-n/ge559-n_assembly-installation-and-operation-instructions_1110393009.webp)
8
Installation (Continued)
Wall Mounting (To Non-Combustible Wall Only)
1.
Fix the wall mounting bracket to the wall
with six screws, in such a position that the
top of the bracket is level and at least 945
mm (38”) above any surface beneath the
unit. This will ensure that the bottom of the
Salamander is at least 600 mm (24”) above
any surface. Refer to Fig. 1 as an example.
2.
Fit the two black plastic spacers to the top
rear corners of the unit. Leave them
unscrewed by approximately 5 mm. Refer to
Fig. 2 (A).
3.
Fit the two adjusting screws / bolts into the
nut inserts at the bottom rear corners of the
unit. These should protrude approximately 30
mm from the rear of the Salamander. Refer
to Fig. 2 (B).
4.
Lift the Salamander onto the wall bracket,
lining up the black plastic spacers on the
salamander with the mounting notches in the
bracket. Refer to Fig. 3.
5.
Lower the Salamander onto the mounting
bracket. Refer to Fig. 4.
6. Tighten the black spacers securely and adjust
the leveling screws / bolts to ensure that the
unit is level. Refer to Fig. 4.
Fig. 1
Screws
94
5m
m
60
0mm
5mm
Fig. 2
30mm
B
A
Fig. 3