6
Installation (continued)
Assembly
NOTE:
•
This appliance is assembled before delivery except feet and rack.
• This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and
level. This should be carried out on completion of the gas connection. Refer to the ‘Gas
Connection’ section.
• IM will be stated that the appliance shall be installed in such a way that side body surfaces are
not accessible in the installed position.
Step 3: Location
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation and exhaust means, to prevent dangerous build-up
of combustion products.
3.
Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. The minimum installation clearances shown below are to be adhered to.
4.
Position the appliance in its approximate working position. In accordance with AS/NZS5601 - Gas
Installations.
5.
All air for burner combustion is supplied from underneath the unit. The legs must always be fitted
and no obstructions placed on the underside or around the base of the unit, as obstructions will
cause incorrect operation and / or failure of the appliance.
6.
Components having adjustments protected by manufacturer are only allowed to be adjusted by an
authorized service agent. They are not to be adjusted by the installation person.
7. Do not place any equipment on top of the appliance
.
8.
The unit should be mounted under an extraction hood incompliance with all local regulations.
In the event that the unit is not mounted under an extraction hood, the installer must
ensure that all regulations are met and that there is an unobstructed minimum distance of
750mm from the top surface of the unit to the ceiling, which must be of non-combustible
material.
NOTE: Do not obstruct or block the appliance’s flue. Never directly connect a ventilation
system to the appliance’s flue outlet.