Specifications 

 

 

General

 

 

Commercial gas salamander. 

 

Pack Contents 
 

The following is included: 

 

Thor Gas Salamander   

 

1pcs racks  

 

4pcs Feet  

optional

 

 

Instruction Manual  

 

Wall Mounting Bracket, including: 

-2 x 25mm Black Plastic Spacer.

 

-2 x 3/8” Bolts/Nuts  

-6x 30mm Screw Tox.

 

-6 x ST4.9x30 screws  

 

Gas Supply Requirements

 

 

 

 

 

 

Natural Gas 

Propane 

 

ULPG 

GE559-N 

GE559-P 

GE559-P 

Single burner Heat Input 

16MJ/Hr 

16 MJ/Hr 

16 MJ/Hr 

Heat Total 

32 MJ/Hr 

32 MJ/Hr 

32 MJ/Hr 

Burner Operating 

1.0 kPa 

2.75 kPa 

              2.75kPa  

Minimum  inlet  supply 

pressure 

1.13 kPa 

2.75 kPa 

2.75 kPa  

Gas Connection 

¾” BSP Male 

¾” BSP Male

 

¾” BSP Male

 

 

 

 

 

 

 

 

The burner operating pressure is to be measured at the gas control valve outlet test point with two burner 
operating at ‘High’ setting. The operating pressure is ex-factory set, through the appliance regulator and should  
not to be adjusted, However the pressure must be checked during installation to confirm adequate supply 

pressure is available. (Test point for checking gas pressure is located by removing right side panel. Turn gas 
supply off before removing test point screw.) 

  

 
Minimum input of burner:   

13MJ   for LPG,   13MJ   for NG                                       

 

 

 
 

 
 
 

 
 
 
 

Summary of Contents for GE559-N

Page 1: ...the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or...

Page 2: ...arances Assembly Gas Connection Commissioning Operation 10 11 Operation Guide Description of Controls Lighting the Main Burner Main burner air supply Cleaning and Maintenance 12 Initial cleaning Daily...

Page 3: ...IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO US...

Page 4: ...rating 1 0 kPa 2 75 kPa 2 75kPa Minimum inlet supply pressure 1 13 kPa 2 75 kPa 2 75 kPa Gas Connection BSP Male BSP Male BSP Male The burner operating pressure is to be measured at the gas control va...

Page 5: ...4 Dimensions Dimensions for Gas Salamander Minimum clearance from grease filter minimum 600mm Refer AS NZS5601 Gas Installations Note Gas Salamander rack can carry a load of up to 15KG 33 lbf...

Page 6: ...Components having adjustments protected by the manufacturer are only to be adjusted by an authorized service agent They are not to be adjusted by the installation person Step 1 Unpacking Step 2a Inst...

Page 7: ...appliance in its approximate working position In accordance with AS NZS5601 Gas Installations 5 All air for burner combustion is supplied from underneath the unit The legs must always be fitted and n...

Page 8: ...m 600mm 750mm We recommend allowing a clearance of 100 mm on either side of the appliance to allow access to the side panels for servicing purposes Using the wall mounting accessories provided with th...

Page 9: ...them unscrewed by approximately 5 mm Refer to Fig 2 A 3 Fit the two adjusting screws bolts into the nut inserts at the bottom rear corners of the unit These should protrude approximately 30 mm from t...

Page 10: ...fixed ex factory for the gas type 3 Correctly locate the appliance into its final operating position and using a spirit level adjust the legs so that the unit is level and at the correct height 4 Con...

Page 11: ...y of a thermo electric system which will shut off the gas supply to that burner in the event that the burner goes out so that un burnt gas is not expelled 1 Select the burner required depress and turn...

Page 12: ...designed and installed hood will act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All val...

Page 13: ...ticles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SOURCING PADS EXCEPT STAINLESS SCRAPPER FILE OR OTHER STEEL TOOLS Surfaces which are ma...

Page 14: ...he left side panel and right side panel 3 Replace the burner injectors See the parts list or Gas Specification Table below 4 Adjust the gas supply pressure and convert the gas regulator 5 Change ratin...

Page 15: ...Page 13 Only one burner in a unit produce excessive carbon deposits Incorrect injector orifice installed Ensure that a correct injector orifice is installed on the unit Refer to Gas Specification Tabl...

Page 16: ...15 Explosion drawing 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 23 22 25 26 27 19 24...

Page 17: ...16 Explosion drawing Continued 29 30 31 32 33 34 35 36...

Page 18: ...05 1029298 1 1 10 Upper inner1 01 15 1066418 1 1 11 Top cover 01 05 1029295 1 1 12 Feet1 02 12 1165053 2 2 13 Back hold plate 01 15 1066412 1 1 14 Back panel 01 15 1066415 1 1 15 Back inner plate 01...

Page 19: ...Main pipe assembly 06 05 1472745 2 2 30 L connector 01 18 1067451 2 2 31 Main burner injector Orifice for Natural Gas 185 01 20 1068670 2 Main burner injector Orifice for LPG 109 01 20 1068671 2 32 I...

Page 20: ...15 Badgally Road Campbelltown NSW 2560 Thor after sales service 1300 225 960 V1 Rev4 12 20...

Reviews: