12
Power Supply Cord Kit
The power supply cord will be connected to the
terminal connection block
located behind the back panel
access cover by manufacture .This appliance should be connected by means of permanent "hard
wiring" or by means of a power supply cord kit.
Risk of fire or electrical shock exists if an incorrect size range cord kit is used, the
Installation Instructions are not followed, or the strain relief bracket is discarded.
Terminal on end of wires must be either closed loop or open spade lug with upturned ends. Cord must
have strain-relief clamp.
CAUTION:
Do not loosen the nuts which secure the factory-installed range wiring to terminal block while
connecting range. Electrical failure or loss of electrical connection may occur.
Access to Terminal Block
Remove the screws at the lower end of the rear access cover and take it down to expose range terminal
connection block.
a) only a 4-conductor power-supply cord kit rated __240__ volts, __30A__ amperes
minimum
and
marked for use with ranges shall be used; and
b) used closed-loop terminal that the cord kit is to employ, as appropriate for the appliance supply
terminals.
Electrical Shock Hazard
•Electrical ground is required on this appliance.
•Donot connect to the electrical supply until appliance is permanently grounded.
•Disconnect power to the circuit breaker or fuse box before making the electrical connection.
• This appliance must be connected to a grounded,metallic, permanent wiring system, or a grounding
connector should be connected to the grounding terminal or wire lead on the appliance.Failure to do