background image

21

Description orders for 01 series, 03 series and 04 series range hood

Automatic activation control function of the sensor:

There are 5 pieces sensor buttons,1pc remote control signal lamp(remote controller included), 2 pieces
stainless steel grease boxes,2 pieces stainless steel baffle filters and 2 pieces led bulbs( 12V/1.5W).
A0 button: Remote control signal lamp
A1 button: Power( on/off)
A2 button: LED bulb
A3 button: Display screen
A4 button: Time Delay. A5 button: Low speed
A6 button: High speed
A4 button equip with Max 15 minutes after power off, A1 button( on/off) control to directly started or
off.

Open The Fan

Keep your hood working during the cooking, and keep ventilating.
Press A1 button, then A3 display screen open.
Button A5 and A6 activates,high speed (F4),average speed(F3), low speed(F2), quiet speed(F1).

Control Panel Layout and Button Disposition

Close The Fan

Off time-delay function just could close the fan, not affected the lamplight setting.

15 minutes time-delay

When fan working, press A4 button, digital screen will blink several seconds, default setting is 1
minute,after that, it will shut off automatically.
During fan working, if you need to adjust time-delay function,press A4 button one time, will blink for a
few seconds, press A6 button to increase delay-time, set the figure timers as the time you want, max
delay-time is 15 minutes.
If time-setting changes from A6 button to A5 button, during the process, speed changes,but does not
affect count down.

Off immediately

Press A1 button two times, fan turn off immediately.

Summary of Contents for HRH3001U

Page 1: ...ge Hood Installation Guide and User Manual Applicable model HRH3001U HRH3002U HRH3003U HRH3004U HRH3005U HRH3006U HRH3601U HRH3602U HRH3603U HRH3604U HRH3605U HRH3606U HRH4801U HRH4802U HRH4805U HRH48...

Page 2: ...o provide sufficient air for proper combustion of heating equipment and proper evacuation of gases through the chimney pipe to prevent back flow of air Follow the instructions and safety standards of...

Page 3: ...to the area where it was formed Firefighters was called You can fight against the fire with an exit behind you Operative Mode Always leave safety grills and filers in place Without the presence of the...

Page 4: ...must be plugged directly into a 110 volt wall outlet Before installing the hood 1 To ensure the most efficient ventilation possible install the pipe in a straight line or with the least elbows possib...

Page 5: ...espect to any loss damage or fire caused by non observance of the instructions contained in this manual Ventilation methods The hood is equipped with a vertical transition to remove fumes outside Reco...

Page 6: ...d ceilings However you should ask a qualified technician to check the strength of materials depending on the type of wall or ceiling Before cutting make sure there is enough clearance in the ceiling o...

Page 7: ...please inspect the maximum height of your ceiling and bonnet Too high will affect the efficiency of the hood too low stove temperature will damage some parts of the hood So the installation height req...

Page 8: ...Identify the two screw holes on the wall Drill pilot holes 5 16 in the locations shown Place the fastening clips to the wall Tighten wood screws by hand in the attachments to allow hooks to expand Rem...

Page 9: ...8 Necessary Tools...

Page 10: ...9 03 Series range hood Walled mounted fixed plated...

Page 11: ...10 Overview size...

Page 12: ...11 Installation dimension figure of 04 series range hood as below...

Page 13: ...12 04 series range hood Walled mounted fixed plated...

Page 14: ...13 Overview size...

Page 15: ...14 01 series 02 series range hood...

Page 16: ...15 05 series 30 inch and 36 inch range hood...

Page 17: ...16 05 series 48 inch range hood...

Page 18: ...17 06 series 30 inch and 36 inch range hood...

Page 19: ...18 06 series 48 inch range hood...

Page 20: ...installation dead plate 2 Fix the installation dead plate to the wall by screws see figure 5 3 Use double faced aluminum foil sealed joint see figure 6 4 Power line color black to black white to white...

Page 21: ...20 Figure4 Figure 5...

Page 22: ...ventilating Press A1 button then A3 display screen open Button A5 and A6 activates high speed F4 average speed F3 low speed F2 quiet speed F1 Control Panel Layout and Button Disposition Close The Fan...

Page 23: ...button F1 low speed F2 medium speed F3 high speed F4 time delay or power on off F5 Light Button Power on press F1 button once turn on the lights and again to turn off Fan button When need to open the...

Page 24: ...urfaces regularly with a cloth or a clean cloth soaked in warm water and mild soap or dish detergent Always clean in the direction of squall lines direction of the grain Always rinse well with clear w...

Page 25: ...hen your range hood is used for other than normal single family household use or when it is used in a manner that is contrary to published user or operator instructions and or installation instruction...

Page 26: ...bove limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state Whenever you call our customer service...

Reviews: