E-DOC-CTC-20071119-0003 v1.0
93
6|
Service Provisioning
6.10 Remote Access (Remote Assistance)
RemoteAccess data model
The IGD data model on the Thomson Gateway contains the object
“InternetGatewayDevice.Services.X_000E50_RemoteAccess.”.
This object can be used to enable remote access to the Thomson Gateway.
The Thomson Gateway supports following
proprietary
RemoteAccess data model:
Message flow
Following illustration shows a possible message flow for the configuration of remote access:
Name
Type
Actions
InternetGatewayDevice.Services.X_000E50_RemoteAccess.
Object
URL
Parameter
Read
Status
Parameter
Read
Secure
Parameter
Read/Write
Port
Parameter
Read/Write
Timeout
Parameter
Read/Write
ElapsedTime
Parameter
Read
Mode
Parameter
Read/Write
IPIntf
Parameter
Read/Write
RandomPassword
Parameter
Read/Write
RandomPort
Parameter
Read/Write
User
Parameter
Read/Write
Password
Parameter
Read
Group
Parameter
Read/Write
Enable
Parameter
Read/Write
Start
Parameter
Write
ACS
CPE
Transaction session
...
2) Apply changes
Configure Remote Access
1) SetParameterValues
3) SetParameterValuesResponse
...
Summary of Contents for TR-069
Page 2: ......
Page 3: ...Thomson Gateway TR 069 Configuration Guide R7 4 and higher ...
Page 18: ...E DOC CTC 20071119 0003 v1 0 12 1 Introduction ...
Page 36: ...E DOC CTC 20071119 0003 v1 0 30 2 Configuring CWMP on the Thomson Gateway ...
Page 74: ...E DOC CTC 20071119 0003 v1 0 68 5 WAN Connections ...
Page 106: ...E DOC CTC 20071119 0003 v1 0 100 6 Service Provisioning ...
Page 109: ......