E-DOC-CTC-20071119-0003 v1.0
21
2|
Configuring CWMP on the Thomson Gateway
2.2.2
CWMP Daemon as seen from the ACS
Displaying configuration information
To obtain an overview of the CWMP daemon configuration as seen from the ACS, execute following
command:
Parameter description
To modify the configuration of the CWMP daemon
as seen from the ACS
, execute the command
:cwmp config
and specify one or several of following optional parameters:
State
: if this parameter is enabled, remote management of the Thomson Gateway by an ACS is allowed.
By default, remote management by CWMP is disabled.
Mode
: one of two operational modes can be selected:
Read-only
: if the operational mode is set to read-only, only read RPC methods are allowed.
A read-only mode is provided for customers that do not want to actively manage the CPE and do not
want to take any security risk. The read-only mode still allows building an inventory of the install-
base CPE.
Full
: to enable both read and write RPC methods, the operational mode must be set to full. This is the
default mode.
PeriodicInform
: if this parameter is enabled, the CWMP client establishes a connection to the ACS
periodically. This means that the CWMP client sends an Inform RPC with a configurable frequency. The
frequency is defined by the parameter
periodicInfInt
.
By default, this parameter is enabled.
PeriodicInfInt
: if the parameter
periodicInform
is enabled, the value of this parameter specifies the
time in seconds (s) between two connection establishments.
By default, the parameter is set to 43200 s. This means that the CWMP client establishes a connection to
the ACS once every 12 hours.
=>:cwmp config
State
: disabled
Mode
: full
Max Envelopes
: 2
Session Timeout
: 60
No Ip Timeout
: 180
Connection Request Port
: 51005
Periodic Inform
: enabled
Periodic Inform Interval
: 43200 s
Connection Request
: disabled
Connection Request UserName
: 000E50-CP0452JT03Y
Connection Request PassWord
: ********
Connection Request Path
:
Connection Request Authentication
: digest
Qos class
: 12
Boot delay range between 0 and
: 0 s
Amendment 1 Session Termination
: disabled
Upgrade delay
: disabled
Persistent Subscriptions
: disabled
This parameter has the same value as the attribute
state
of the CWMP client service. For
more information, see
“2.2.1 CWMP Service Manager” on page 19
.
As more operators are performing TR-069 tests and become ready to deploy it, there is less use
and request for a read-only mode.
Summary of Contents for TR-069
Page 2: ......
Page 3: ...Thomson Gateway TR 069 Configuration Guide R7 4 and higher ...
Page 18: ...E DOC CTC 20071119 0003 v1 0 12 1 Introduction ...
Page 36: ...E DOC CTC 20071119 0003 v1 0 30 2 Configuring CWMP on the Thomson Gateway ...
Page 74: ...E DOC CTC 20071119 0003 v1 0 68 5 WAN Connections ...
Page 106: ...E DOC CTC 20071119 0003 v1 0 100 6 Service Provisioning ...
Page 109: ......