25
EN
D - INSTALLATION
5 - REMOTE CONTROL
Remove tape to activate battery.
MOTORISED KIT WITH ARTICULATED ARMS
FOR SINGLE OR DOUBLE LEAF SHUTTERS
6 - CONNECTING A wIRED CONTROL SwITCH (OPTIONAL)
To be operational, the white wire and the other two wires must be in contact depending on whether you
want to open or close the door.
- White and blue contact: closure
- White and red contact: opening
As soon as they are no longer in contact, the gear stops.
If always in contact while the shutter is fully open or closed, the gear motor will stop but the radio control will
be blocked.
2 pushbuttons
1 two-stage button
1 three-stage button
As there is a wide range of shutter switches, follow the operating principle outlined above to wire the switch
correctly.
Caution: In oder to operate the radio control, the white wire should not remain in contact with
either of the two other wires when the movement is complete.
CAUTION : Do not connect
these three wires to 230V
mains, as they carry very
low voltage signals.
1
P
2
P
Red
Blue
White
Gear motor
Red
Blue
White
Gear motor
P
1
2
Red
Blue
White
Gear motor
P
1
3
2