Route the power cable.
Wires (power supply, antenna cables) must not be in contact with any mobile part.
4 - CONNECTING THE MOTOR
Safety instructions:
Cut out electrical power (circuit breaker in OFF position) before performing any operations. The installation
must be made by qualified personnel.
Connect the power cable to the mains using a cable of 2x0,75mm² min.
Important notes:
The power line must be used exclusively to power your motorised shutters and must be protected by a
fuse, circuit breaker or residual current device (30mA). Compliance with electricity safety regulations is
required.
EN
24
D - INSTALLATION
MOTORISED KIT WITH ARTICULATED ARMS
FOR SINGLE OR DOUBLE LEAF SHUTTERS
OFF
to the neutral
Conductor of
electric power
to the conductor
Phase electric
power
blue
brown