VelocityDVI-6 A/N+ Transmitter 

Velocity

MRTS 

Technology

Dual-Link DVI

Transmitter

D

V

I

fr

o

m

 C

P

U

D

V

to

L

o

c

a

D

is

p

la

y

dvi

Powered by

Digital Video Extension System – 6A/N+

M

ic

 

O

u

t

L

in

e

 

In

1

0

0

1

0

F

D

C

OL

N

e

two

rk

D

D

C

 M

o

d

e

A

c

q

u

ir

e

S

e

le

c

t

R

E

M

L

C

L

L2  

Data

L1 

Video/Data

Status

+

5VDC

Power

FOL

TX

RX

LNK/ACT

7.00" (177.80mm) L x 7.49" (190.25mm) W x 1.10" (27.94mm) H

L3 

Video

Lower Connector

Lower Connector

T

ra

n

s

m

itt

e

r

D

V

fr

o

m

 C

P

U

D

V

to

 L

o

c

a

D

is

p

la

y

T

ra

n

s

m

it

te

r

 

 

 

Rear Panel Network Status LEDS:

10/100:

When 

lit

, speed of link is 

100 Mb/sec

.

When 

off

, speed of link is 

10 Mb/sec

.

FD/COL:

When 

lit

, indicates operation in 

Full Duplex

.

When 

off

, indicates operation in 

Half Duplex

.

When 

blinking

, indicates 

Collision

.

On the RJ45 Connector:

Green LED = Link

Yellow LED (blinking) = Activity

Front Panel Network Status LEDS:

FOL

is ON when 

F

iber 

O

ptic 

L

ink is OK.

TX

is ON when data is transferring from TX to RX.

RX 

is ON when data is transferring from RX to TX.

LNK/ACT 

is

ON

when link is established. 

Flashes 

when actively transferring data.

 

 
 
 

Summary of Contents for Velocitydvi-3

Page 1: ...tydvi 3 Velocitydvi 33 Velocitydvi 6 Velocitydvi 63 Single Link and Dual Link Fiber Extension Systems Thinklogical LLC 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 Fa...

Page 2: ...gical LLC 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are the property of their respective owners Subject VelocityDVI 3 VelocityDVI...

Page 3: ...ONS 14 3 2 1 TABLE OF VELOCITYDVI CHASSIS DIMENSIONS 30 4 DDC DISPLAY DATA CHANNEL AND EDID EXTENDED DISPLAY IDENTIFICATION DATA 31 4 1 DEFAULT DDC MODES 31 4 1 1 REMOTE DYNAMIC MODE 31 4 1 2 REMOTE S...

Page 4: ...DUCT SUPPORT 37 6 2 1 WARRANTY 37 6 2 2 RETURN MERCHANDISE AUTHORIZATION 38 APPENDIX A INSTALLATION OVERVIEW 39 A 1 VEL 3 39 A 2 VEL 3 A V 40 A 3 VEL 6 41 A 4 VEL 6 A V 42 A 5 VEL 33 43 A 6 VEL 63 44...

Page 5: ...e mode fiber optic cables to allow the placement of video devices up to 10 40 or 80 km 6 2 24 8 49 7 miles away from the controlling computer without loss of resolution Installation is plug and play a...

Page 6: ...Digital Video Extension System 63 MRTS Technology Transmitter dvi Powered by STATUS STATUS STATUS Digital Video Extender 6 Velocitydvi Digital Video Extender 3 Velocitydvi Velocitydvi Digital Video Ex...

Page 7: ...3 SINGLE LINK DVI DDC MULTIMODE RX ST VEL 000M33 STTX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX ST VEL AV0S03 SCRX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL...

Page 8: ...VI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VEL AN0M03 SCTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTI MODE TX SC VE...

Page 9: ...UAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTI MODE TX LC VEL AV0M06 SCRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VEL AV0M06 SCTX VELOCITY...

Page 10: ...ORT DDC SERIAL AUDIO MULTI MODE TX SC VEL AN0M06 STRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX ST VEL AN0M06 STTX VELOCITY 6 A N DVI VIDEO EXTENDER...

Page 11: ...ay from the monitor allows more control of your computer environment It is now possible to position your monitor or projector in any setting from office to lecture hall to boardroom while keeping the...

Page 12: ...only be gathered from the TX local port or the Thinklogical default EDID table 2 4 Dual Fiber Operation System 3 In this mode video information is transmitted from the TX to the RX over fiber L1 Fibe...

Page 13: ...mensions See page 30 Shipping Weight 4 lb 1 81 kg pair Vel 3 Vel 6 13 lb 5 89 kg pair Vel 33 Vel 63 Optical Cable Sys 3 2 fibers Sys 33 6 fibers Sys 6 3 fibers Sys 63 9 fibers available not supplied O...

Page 14: ...nnections to these products use industry standard connectors It is recommended that you securely mount each VelocityDVI chassis before installing the cabling and power sources Please refer to the foll...

Page 15: ...s The AC wall pack has a universal power rating of 100 240VAC 50 60Hz and also has interchangeable wall plug adapters for various international AC power receptacles below 5VDC Continuous Short Circuit...

Page 16: ...Page 14 3 2 The VelocityDVI 3 6 33 and 63 Chassis Configurations The models depicted on pages 14 30 provide an overview of the various dimensions connectors and features available on Thinklogical s V...

Page 17: ...STATUS _ POWER 5 VDC STATUS _ DDC MODE LCL REM ACQUIRE SELECT DDC MODE LCL REM ACQUIRE SELECT L1 L2 L2 L1 Velocity Digital Video Extension System 3 with Neutrik Connector MRTS Technology Transmitter d...

Page 18: ...lay dvi Powered by 7 00 177 80mm 7 50 190 50mm 6 50 165 10mm 1 10 27 94mm L2 Data L1 Video Data Physical dimensions are the same for both the Transmitter and Receiver chassis DDC MODE LCL REM ACQUIRE...

Page 19: ...Local Display dvi Powered by 7 00 177 80mm 7 50 190 50mm 6 50 165 10mm 2 0 50 80mm Physical dimensions are the same for both the Transmitter and Receiver chassis RECEIVER POWER 5VDC STATUS _ DDC MODE...

Page 20: ...190 25mm W x 1 10 27 94mm H VelocityDVI 3 A N Transmitter Audio Network Front Panel Network Status LEDS FOL is ON when Fiber Optic Link is OK TX is ON when data is transferring from TX to RX RX is ON...

Page 21: ...25mm W x 1 10 27 94mm H VelocityDVI 3 A N Receiver Audio Network Rear Panel Network Status LEDS 10 100 When lit speed of link is 100 Mb sec When off speed of link is 10 Mb sec FD COL When lit indicat...

Page 22: ...x 7 49 190 25mm W x 2 00 50 80mm H VelocityDVI 3 A N Transmitter with Neutrik OpticalCon DUO Connector Rear Panel Network Status LEDS 10 100 When lit speed of link is 100 Mb sec When off speed of lin...

Page 23: ...d of link is 100 Mb sec When off speed of link is 10 Mb sec FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision On the RJ45...

Page 24: ...Powered by 7 75 196 85mm 5 50 139 70mm 4 50 114 30mm 1 10 27 94mm POWER 5VDC STATUS _ DDC MODE LCL REM ACQUIRE SELECT DVI from CPU DVI to Local Display POWER 5VDC STATUS _ DDC MODE LCL REM ACQUIRE SE...

Page 25: ..._ POWER 5 VDC STATUS _ DDC MODE LCL REM ACQUIRE SELECT DDC MODE LCL REM ACQUIRE SELECT L1 L2 L2 L1 Velocity Digital Video Extension System 6 with Neutrik Connector MRTS Technology Dual Link DVI Transm...

Page 26: ...m 7 50 190 50mm 6 50 165 10mm 1 10 27 94mm Physical dimensions are the same for both the Transmitter and Receiver chassis DDC MODE LCL REM ACQUIRE SELECT POWER 5 VDC STATUS _ DVI from CPU DVI to Local...

Page 27: ...dvi Powered by 7 00 177 80mm 7 50 190 50mm 6 50 165 10mm 2 44 61 98mm Physical dimensions are the same for both the Transmitter and Receiver chassis RECEIVER POWER 5VDC STATUS _ DDC MODE LCL REM ACQUI...

Page 28: ...eo Lower Connector Lower Connector Transmitter DVI from CPU DVI to Local Display Transmitter Rear Panel Network Status LEDS 10 100 When lit speed of link is 100 Mb sec When off speed of link is 10 Mb...

Page 29: ...eo Lower Connector Upper Connector Receiver DVI to Display DVI to Display DDC Receiver Rear Panel Network Status LEDS 10 100 When lit speed of link is 100 Mb sec When off speed of link is 10 Mb sec FD...

Page 30: ...peed of link is 100 Mb sec When off speed of link is 10 Mb sec FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision On the R...

Page 31: ...L x 7 49 190 25mm W x 2 00 50 80mm H L2 Data Velocity 6 A N Receiver with Neutrik QUAD OpticalCon Connector Rear Panel Network Status LEDS 10 100 When lit speed of link is 100 Mb sec When off speed o...

Page 32: ...50 80mm VEL 3 AN 7 5 W x 7 0 D x 1 1 H 190 50mm x 254 00mm x 27 94mm VEL 3 AN w Neutrik 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm VEL 6 5 5 W x 7 75 D x 1 1 H 139 65mm x 196 85mm x 27 94mm...

Page 33: ...to the RX Advantages Allows CPU video card to boot when there is no fiber connection to the RX Limitations No communication link from the CPU to the display Prevents the use of HDCP or monitor configu...

Page 34: ...ower resolution capability is connected to the RX 4 2 Load Default EDID Table Holding the ACQUIRE and SELECT buttons for 5 seconds will reload the default DDC table into the TX and switch the DDC mode...

Page 35: ...emote Static mode Local and Remote LED Mode Indication LCL REM DDC MODE DESCRIPTION REMOTE DYNAMIC REMOTE STATIC PASS THRU LOCAL STATIC EDID READ FROM REMOTE DISPLAY AND UPDATED EACH TIME REMOTE DISPL...

Page 36: ...electrical ground if required 5 Regulatory and Safety Compliance 5 1 Symbols Found on Our Products Markings and labels on our products follow industry standard conventions Regulatory markings found o...

Page 37: ...Test EN61000 4 4 1995 Electrical Fast Transient Test EN61000 4 5 1995 Power Supply Surge Test EN61000 4 6 1996 Conducted Immunity Test EN61000 4 8 1993 Magnetic Field Test EN61000 4 11 1994 Voltage D...

Page 38: ...ho are most familiar with your products Thank you for choosing Thinklogical products for your application We appreciate your business and are dedicated to helping you successfully use our products is...

Page 39: ...resentatives have direct numbers to facilitate your next call to us Fax Our company facsimile number is 1 203 783 9949 Please indicate the nature of the fax on your cover sheet and provide return cont...

Page 40: ...elp If you must return a product to Thinklogical directly Customer Support will ask you to describe the problem and will issue you a Return Merchandise Authorization number RMA Pack the device in its...

Page 41: ...Connect the supplied AC Power Adapter PWR 000022 R to the Rx and plug it into a standard AC source 3 STEP 3 Connect the DVI to Display DDC port to a video monitor or projector or other viewing device...

Page 42: ...V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l R e v G M a y 2 0 1 3 Page 40 A 2 VEL 3 A V...

Page 43: ...PWR 000022 R to the Rx and plug it into a standard AC source 3 STEP 3 Connect the DVI to Display DDC port to a video monitor or projector or other viewing device with a DVI D M M Cable A second device...

Page 44: ...the Rx and plug it into a standard AC source 3 STEP 3 Connect the DVI to Display DDC port to a video monitor or projector or other viewing device with a DVI D M M Cable A second device can be installe...

Page 45: ...ct the multi mode fiber optic cables between the Tx and Rx Units up to 1000 meters Do not kink or pinch the cables and be sure to keep all bend radii to no less than 3 inches STEP 5 Using the supplied...

Page 46: ...V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l R e v G M a y 2 0 1 3 Page 44 A 6 VEL 63...

Page 47: ...with Neutrik 5 375 W x 7 0 D x 2 0 H 136 65mm x 177 80mm x 50 80mm Vel 3 AV 7 5 W x 7 0 D x 1 1 H 190 50mm x 177 80mm x 27 94mm Vel 3 AV w Neutrik 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm V...

Page 48: ...V e l o c i t y D V I E x t e n d e r P r o d u c t M a n u a l R e v G M a y 2 0 1 3 Page 46 Appendix C RJ 45 Adapter Pin outs...

Page 49: ...addition to offering a redundant fiber connector L1 for each standard fiber connector L1 All other features function as described previously in the manual Velocity 3 TX with Automatic Fail Over Fiber...

Reviews: