![Thinklogical TXL 640 User Manual Download Page 16](http://html1.mh-extra.com/html/thinklogical/txl-640/txl-640_user-manual_1107270016.webp)
®
TLX Matrix Switch SNMP Traps Manual
12
Rev. E - July, 2015
TLX48 HARDWARE ALARMS (Alarm Contacts)
TLX48 Power Supply Failure
Begin and Clear
Contact 1
A Power Supply has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,27
Clear OID:
1,3,6,1,4,1,17658,3,14,0,28
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
TLX48 Fan Failure
Begin and Clear
Contact 2
A fan in the Fan Tray has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,29
Clear OID:
1,3,6,1,4,1,17658,3,14,0,30
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
TLX48 High Temperature
Begin and Clear
Contact 3
The system has detected a temperature that is above the preset alarm threshold (Begin) or is now below the
preset alarm threshold (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,31
Clear OID:
1,3,6,1,4,1,17658,3,14,0,32
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
Summary of Contents for TXL 640