![Thinklogical TXL 640 User Manual Download Page 14](http://html1.mh-extra.com/html/thinklogical/txl-640/txl-640_user-manual_1107270014.webp)
®
TLX Matrix Switch SNMP Traps Manual
10
Rev. E - July, 2015
Low RX
Power Warning
Begin and Clear
An SFP module has the ability to monitor and trigger an alarm on a
high or low RX laser power
reading.
This ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when
bit 6 of byte 117
in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).
This bit is set when the SFP received laser power falls below the low power warning level. The SFP RX
power value is stored at
bytes
104 & 105
of the SFP diagnostic register table.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,39
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,40
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowRxPowerWarning
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
Summary of Contents for TXL 640
Page 1: ......