TLX Matrix Switch SNMP Traps Manual
11
Rev. E - July, 2015
(SFP) EVENTS
SFP
Removed and Inserted
An SFP module has been removed or inserted.
Removed OID: 1,3,6,1,4,1,17658,2,2,2,0,41
Inserted OID: 1,3,6,1,4,1,17658,2,2,2,0,42
Objects:
1: sfpLabel
2: sysContact
3: sysDescr
4: sysLocation
5: sysName
TX Fault Begin and Clear
An SFP module has entered into the TX Fault state (Begin) or has exited the TX Fault state (Clear). This
state is determined by the TxFault status bit located in the SFP diagnostic registers.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,43
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,44
Objects:
1: sfpLabel
2: sysContact
3: sysDescr
4: sysLocation
5: sysName
LOS
Begin and Clear
An SFP module has entered into the LOS state (Begin) or has exited the LOS state (Clear). This state is
determined by the LOS status bit located in the SFP diagnostic registers.
This trap is not conditioned by the switch matrix, but is the LOS status of the SFP. For example,
this trap will
be generated when a fiber is removed from the SFP or when an existing connection is broken by the
switch matrix.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,45
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,46
Objects:
1: sfpLabel
2: sysContact
3: sysDescr
4: sysLocation
5: sysName