Command HK,HB,HG
<id>HK<para5>
Switch on/off head heatings
<id>HB<para5>
Switch on/off carrier heatings
<id>HG<para5>
Switch on/off housing heating
Description:
With this commands the heating circuits can be switched on (parameter 1) for
testing purpose (only 5.4110.x
1
.xxx). After one minute the respective circuit is
switched off automatically. With the parameter 0 the circuit can be switched off
immediately. Duty cycle should be at most 50% (at 20°C ambient temperature)
or else overheating can occur.
Value range:
0,1
Initial value:
-
Attention:
Head and carrier heatings could be hazardous hot! Burn
Hazard! (applies only for 5.4110.x1.xxx)
Command ZB
<id>ZB
Request of operating hours (resolution 2 hours)
Description:
Output of the operating hours (resolution 2 hours) of the sensor.
Value range:
0…99999 (-> 22.8 years)
Initial value:
0
35 - 66
021341/07/11
Summary of Contents for 5.4110 00 Series
Page 65: ...65 66 021341 07 11...