34 - 66
021341/07/11
Example reply in case of no error :
„
0;0;0;0;0;0;0;0;0;0;0;0;0;0;0;0“
(laser on, no error and warning detected)
Value range:
-
Initial value:
-
Command FM
<id>FM
Output of error counter
Description:
Output of the error counter 1 to 15 (number corresponds to “DX” command)
Note:
•
Reset of error: see command “RF”
•
The error counter is incremented when the error is no more present
Example reply:
„0005;0000;0000;0000;0000;0000;0002;0000;0000;0000;0000;0000;0000;0000;0000“
5 times error 1: Static signal out of allowed range
2 times error 7: Current pane heating laser head
Value range:
0…9999
Initial value:
0
Command RF
<id>RF00001
Reset of error counters
Description:
All error counters are set to 0.
Value range:
1
Initial value:
-
Summary of Contents for 5.4110 00 Series