Thies CLIMA 5.4103.20.041 Instructions For Use Manual Download Page 11

 

© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany    

 

 

021335/05/18  

Phone +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·

www.thiesclima.com

  

 

Page 11 of 12 

11 EC-Declaration of Conformity 

 

Document-No.:  000902 

Month:  05  Year:  18 

 

Manufacturer: 

A D O L F   T H I E S   G m b H   &   C o.  K G

 

Hauptstr. 76 
D-37083 Göttingen        
Tel.: (0551) 79001-0  
Fax: (0551) 79001-65      
email: 

[email protected]

 

 

This declaration of conformity is issued under the sole responsibility of the manufacturer 
 

Description of Product: 

Precipitation Transmitter 

 

Article No. 

5.4103.10.000 

5.4103.10.012 

5.4103.10.112 

5.4103.10.700 

 

5.4103.11.000 

5.4103.20.041 

5.4103.20.641 

5.4103.20.741 

 

5.4103.21.021 

5.4103.30.000 

5.4103.30.700

 

5.4103.31.000 

 

5.4103.32.000 

 

 

 

  

 

 

 

 

specified technical data in the document: 
 

021196/04/16; 021334/05/18; 021469/11/09; 021704/07/12 
021767/11/14; 021775/08/14; 021831/03/18; 021833/03/18 

 

The indicated products correspond to the essential requirement of the following European Directives and Regulations: 

 
 

2014/30/EU 

DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 
on the harmonisation of the laws of the Member States relating to electromagnetic compatibility 
 

2014/35/EU 

DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 
on the harmonisation of the laws of the Member States relating to the making available on the market of 
electrical equipment designed for use within certain voltage limits 

 
552/2004/EC 

Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004  
on the interoperability of the European Air Traffic Management network  (the interoperability Regulation) 

 
2011/65/EU 

DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL  

of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical  and electronic 

equipment 

 

2012/19/EU 

DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

 

 

of 4 July 2012 on waste electrical and electronic equipment (WEEE) 

 
The indicated products comply with the regulations of the directives. This is proved by the compliance with the following 
standards: 

 

EN 61000-6-2 

Electromagnetic compatibility 
Immunity for industrial environment 

 

 

EN 61000-6-3 

Electromagnetic compatibility 
Emission standard for residential, commercial and light industrial environments 

 

 

EN 61010-1 

Safety requirements for electrical equipment for measurement, control, and  laboratory use.      
Part 1: General requirements 

 

EN 50581 

Technical documentation for the assessment of electrical and electronic products with respect to the 
restriction of hazardous substances 

 
Place:  Göttingen                                                                         Date:  16.05.2018     
Signed for and on behalf of: 

 

 

This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. 
Please pay attention to the security advises of the provided instructions for use.

 

Summary of Contents for 5.4103.20.041

Page 1: ...Precipition Sensor Instruction for Use with analogue Intensity Output 5 4103 20 041 5 4103 20 641 5 4103 20 741 Dok No 021335 05 18 T H E W O R L D O F W E A T H E R D A T A...

Page 2: ...e product is designed for a specific application as described in these operating instructions The device product should be operated with the accessories and consumables supplied and or recommended by...

Page 3: ...and Mode of Operation 4 4 Recommendation Side Selection Standard Installation 5 5 Installation 6 5 1 Mechanical Mounting 6 5 2 Electrical Mounting for Precipitation Sensor with Cable Gland 6 5 3 Elect...

Page 4: ...vided into 4 linear characteristic segments which show a tenth of the slope of the more sensitive segment Thus it is possible to represent an intensity range from approx 0 001mm min light drizzle up t...

Page 5: ...79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 5 of 12 4 Recommendation Side Selection Standard Installation Order No 5 4103 20 041 5 4103 20 641 Clamp connection Order No 5...

Page 6: ...he precipitation can easily reach the sensor field and that the instrument while operating is not exposed to strong vibrations or shocks The pictured tube is not included in delivery 5 2 Electrical Mo...

Page 7: ...g wire 5mm 5 Soldering wire to the insert 6 Positioning shield in cable clamp 7 Screwing on cable clamp 8 Assembling remaining parts acc to upper plan 9 Tightening pull relief of cable by screw wrench...

Page 8: ...mA 0 0025 x 0 01 Segment 2 0 01 0 1 mm min 8 0 12 0 mA 0 0225 x 0 17 Segment 3 0 1 1 0 mm min 12 0 16 0 mA 0 225 x 2 6 Segment 4 1 0 10 0 mm min 16 0 20 0 mA 2 25 x 35 max load 400 Ohm Active sensor...

Page 9: ...bH Co KG Hauptstra e 76 37083 G ttingen Germany 021335 05 18 Phone 49 551 79001 0 Fax 49 551 79001 65 info thiesclima com www thiesclima com Page 9 of 12 9 Dimension diagram 5 4103 20 041 5 4103 20 64...

Page 10: ...of 12 10 Accessories Optional Power Supply Unit 9 3388 00 002 The power supply unit provides for the current supply of the Precipitation Sensor It supplies the necessary operation voltage for the ele...

Page 11: ...to the making available on the market of electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliament and the Council of 10 Mar...

Page 12: ...001 65 info thiesclima com www thiesclima com Page 12 of 12 Please contact us for your system requirements We advise you gladly ADOLF THIES GMBH CO KG Meteorology and environmental metrology Hauptstra...

Reviews: