![Thies CLIMA 5.4103.10.000 Instructions For Use Manual Download Page 9](http://html1.mh-extra.com/html/thies-clima/5-4103-10-000/5-4103-10-000_instructions-for-use-manual_1106921009.webp)
9 - 12
021197/11/09
9 Technical
Data
Measuring value
: Status of precipitation (rain, snow, hail, etc.)
Output
: Precipitation = relay OFF
( also at U
B
= 0)
; no precipitation = relay ON
Sensor area
: 25 cm
2
Drop size
:
≥
0,2 mm
Switch-on condition
: 1... 15 incidences within 50 sec.
Switch-on delay
: none
Switch-off delay
: 25 ... 375 s ; see „
Adjusting incidences and switch-off delay
“
Contact loading (relay)
with model
5.4103.10.000
with model
5.4103.10.700
: max. 230 V AC; 4 A
: max. 60 V AC; 4 A
Operating voltage
: 24 V AC/DC
±
15 %
Operation current
maximal
: approx. 300 mA @20°C ambient temperature
: approx. 1 A
Ambient temperature
: -30 ... +60°C
Protection
: IP 65 acc. to DIN 40050
EMV
: EN 61000-6-2 ; EN 61000-6-3
Weight
: 0,4 kg
Connection See
model