4.3 Electrical Mounting for Precipitation with Plug Connection
The electrical connection is carried out by plug in accordance with the connecting diagram.
4.3.1 Plug
Mounting
Applies only to instruments with connection „plug“.
Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp
Cable connection: without cable shield
Cable- pull- relief
1. Stringing parts on cable acc. to plan given above.
2. Stripping cable sheath 20 mm
3. Cutting uncovered shield 20 mm
4. Stripping wire 5mm.
5. Soldering wire to the insert
6. Positioning shield in cable clamp.
7. Screwing-on cable clamp.
8. Assembling remaining parts acc. to upper plan.
9. Tightening pull-relief of cable by screw-wrench (SW16 und 17).
Cable clamp
Cable sheath
Wire
5 Taking into Operation
After the electrical connection has been established, and the case has been screwed, the operating
voltage can be switched on. The setting of the relay output is undefined after switching on the
operating voltage and shows „no precipitation“.
6 Maintenance
The device is maintenance free.
Cleaning
:
The pollution and the pollution level is dependent on the location. Therefore, we recommend the
unit be checked at appropriate intervals and cleaned if necessary.
For the cleaning should use a damp cloth without chemical cleaning agents are used.